Tetra® Power Supply GEPS12W-60M Installation Guide
2
NOTE: To avoid overloading this
power supply with LED modules,
please refer to the specific
module loading guides.
Power Supply Installation
Black (-)
Green with
yellow stripe White (+)
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm2)
twist-on wire connectors. Properly
ground (green wire with yellow
stripe) power supply in accordance
with National Electric Code (NEC)
Article 600.
Power Supply
Conduit
Power Supply
input wires
AC Line
Run AC line through conduit and
attach conduit to outdoor-rated/
UL approved enclosure. Attach
power supply to enclosure.
Connect the red stripe wire (+) of
the LED strip to the red wire (+)
of the power supply. Connect the
white wire (-) of the LED strip to the
black wire (-) of the power supply.
To power supply
Red (+)
Red stripe (+)
White (-) Black (-)
NOTE: All electrical connections
should be made within the letter.
Mount Power Supply in a
horizontal orientation with a
minimum of one screw per
mounting plate (two screws per
power supply) with the base in
contact with the mounting surface
in accordance with the power
supply spacing requirements
described above.
Tighten liquid-tight fittings and
properly replace cover on junction
box to ensure a water-tight seal.
If not protected from the weather,
the output connections may
be sealed with electrical grade
silicone.
NOTE: Exceeding maximum load
per bank will cause the power
supply to shut down. Once the
excess load is removed, cycle the
input power to restart the power
supply.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm2).
• Follow all local codes.
• Application considerations potentially requiring additional
spacing include high ambient temperature seen by the
power supply, poor contact with a heat dissipating material,
inadequate ventilation, or direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra®.
RISQUES D’INCENDIE
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
• Certaines applications pourraient requérir un espacement additionnel, p. ex.
une température ambiante élevée autour du bloc d’alimentation, un mauvais
contact avec une matière dissipatrice de chaleur, une ventilation inadéquate
ou une exposition directe au soleil.
1
4
2
5
3
CAUTION / ATTENTION
RISK INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes
de sécurité ou des lunettes de protection doivent être portées.