Immersion GELP24-100U-GLX Power Supply Ghid de instalare

Tip
Ghid de instalare
Installation to be performed by factory trained service
personnel only.
For use inside a commercial refrigeration case with packaged
foods only.
Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
Before installing, servicing or cleaning unit, switch power off
at the service panel and follow appropriate lock out/tag out
safety procedures
FOR YOUR SAFETY
Read and observe all CAUTIONS and WARNINGS shown
throughout these instructions.
2424
Volt
BG Българската версия на инструкциите за инсталаця и
информация за безопасност могат да бъдат намерени
на следния адрес: https://products.LED.com/eu
CS Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.LED.com/eu
DA Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan ndes på følgende placering:
https://products.LED.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen nden Sie in folgendem Verzeic:
https://products.LED.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.LED.com/eu
ES La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.LED.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu
FI Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.LED.
com/eu
FR La version française des instructions d’installations et
information de sécurité est disponible à l’adresse suivante:
https://products.LED.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://products.
LED.com/eu
HU A telepítési útmutató és a biztnosági információk magyar
nyelvű változata az alábbi címen található: https://
products.LED.com/eu
IT La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.LED.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.LED.
com/eu
LV Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.LED.com/eu
NL De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.LED.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w następującej
lokalizacji: https://products.LED.com/eu
PT A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.LED.com/eu
RO Versiunea în limba românǎ a instrucţiunilor de instalare
şi a informaţiilor de siguranţǎ pot  gǎsite la: https://
products.LED.com/eu
SV Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen på
följande plats: https://products.LED.com/eu
SL Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
LED.com/eu
SK Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.LED.com/eu
For the latest North American install guides for your product go to: https://products.LED.com/sign-lighting/tetra-max
For the latest European install guides for your product go to: https://products.LED.com/eu
Electrical Requirements
The power supply must be supplied with 120-277 VAC,
50/60 Hz, and connected to an individual properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker or
time delay fuse.
Wiring must be 2 wire with ground and rated for 75°C (167°F).
All wiring must be done to NEC or local electrical codes.
PREPARE ELECTRICAL WIRING
Grounding Instructions–Cable Direct
This lighting system must be connected to a grounded
metal, permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and be
connected to the equipment grounding terminal.
Vertical & Horizontal Cases
93077673 100W LED Driver
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and
specifications subject to change without notice. All values are design or typical values
when measured under laboratory conditions.
Page 1 of 3
(Rev 06/26/23)
DISP105-LED-Refrigerated-Display-Lighting-Immersion-GELP24-100U-GLX-Driver
Installation Guide
DISP105
EN
BEFORE YOU BEGIN
Read these instructions completely and carefully.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the
Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Connect LED Driver - Output
1
• For retrot, place LED driver in the location where the ballast was formerly located.
• Make output (DC) connections as noted below:
Using the wiring diagram in step 3, connect the LED Driver output leads to the LED Light leads using wire connectors or other connection
method approved for low temperature usage and solid conductors.
For Retrot: Bundle and safely secure any unused wires by way of approved wire ties and wire connectors.
A
Mount the LED Driver to a grounded metal portion of the door frame, connect the LED driver housing to an existing equipment grounding
conductor, or run an equipment grounding conductor to the equipment grounding terminal. Using the wiring diagram in step 3, connect
the original Line and neutral wires (or Line 1 and Line 2 wires for 277 maximum VAC) to the LED Driver leads using wire connectors or other
connection method approved for low temperature usage and solid conductors.
Make input (AC) connections as noted below.
The LED Driver is required to be reliably bonded to the protective ground conductor.
Connect LED Driver - Input
2
B
C
ImmersionTM GELP24-100U-GLX Driver Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and
specifications subject to change without notice. All values are design or typical values
when measured under laboratory conditions.
Page 2 of 3
(Rev 06/26/23)
DISP105-LED-Refrigerated-Display-Lighting-Immersion-GELP24-100U-GLX-Driver
UL WARNING / AVERTISSEMENT UL
Risk of electrical shock. Disconnect power before servicing or installing product. LED Retrot Kit Installation requires knowledge of luminaires electrical systems. If not
qualied, do not attempt installation. Contact a qualied electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the
photographs and/or drawings.
Risque de choc électrique. Couper le courant avant de réparer ou installer le produit. LED Retrot Kit d’installation nécessite la connaissance des systèmes
luminaires électriques. Si vous n’êtes pas qualié, ne tentez pas l’installation. Contactez un électricien qualié. Installez ce kit seulement dans les luminaires qui ont les
caractéristiques de construction et les dimensions gurant sur les photographies et / ou des dessins.
WARNING / AVERTISSEMENT
Risk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code.
Risque de choc électrique. S’assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le
NEC ou par le code électrique local.
CAUTION / ATTENTION
Risk of injury. While performing installations described, gloves, safety glasses or goggles should be worn.
Risque de blessure. Lors de l’exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.
CAUTION / ATTENTION
Risk of injury. Do not overload LED Driver, 60-watts maximum per driver. Do not exceed the LED light bar loading limits specied on the light bar
installation instructions for a 60W driver.
Risque de blessure. Ne pas surcharger l’alimentation à DEL. Maximum de 60 watts par alimentation. Ne pas excéder les limites de charge maximale des
alimentations telles que spéciées dans les instructions d’installation.
Troubleshooting
Symptom Solution
All LED lights are OFF The GELP24-100UGLX features a new built in output overload shutdown feature that automatically resets
when the AC supply is removed and reapplied. So if all LED lights are off, rst verify whether or not the
output can be reset by rst switching off then switching back on the AC supply. If the LED lights do not
re-light, then proceed to the following solutions.
Check AC input connection and/or check circuit breaker.
Check wire connection(s) at the LED System and power supply for improper termination(s) or short circuits.
Properly terminate or replace the wire connection(s).
Check that connections are the (+) wire of the LED light to the (+) wire of the power supply and the (-) wire
of the LED light to the (-) wire of the power supply.
Ensure the overall LED load does not exceed the maximum load. If so, remove the excess load, and cycle
the AC supply to reset the drivers built in overload protection.
Some LEDs appear dim Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the LED lights
are not illuminated
Check wire connection(s) at the LED light and power supply for improper termination(s) or short circuits.
Properly terminate or replace the wire connection(s).
Check that connections are the (+) wire of the LED light to the (+) wire of the power supply and the (-) wire
of the LED light to the (-) wire of the power supply.
18 AWG/0.82 mm2
Supply Wire
16 AWG/1.31 mm2
Supply Wire
14 AWG/2.08 mm2
Supply Wire
12 AWG/3.31 mm2
Supply Wire
100W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Remote Mounting Distance
Typical Installation
TERMINAL BLOCK
(AC SOURCE)
LED LIGHT LOAD
3
Connection Congurations
For information on A, B, C, see Steps 1 and 2.
Refer to LED Light Bar installation instructions for
LED light bar wiring congurations.
ImmersionTM GELP24-100U-GLX Driver Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and
specifications subject to change without notice. All values are design or typical values
when measured under laboratory conditions.
Page 3 of 3
(Rev 06/26/23)
DISP105-LED-Refrigerated-Display-Lighting-Immersion-GELP24-100U-GLX-Driver
  • Page 1 1
  • Page 2 2
  • Page 3 3

Immersion GELP24-100U-GLX Power Supply Ghid de instalare

Tip
Ghid de instalare