Tetra 24V GEPS24-100U-GLX Signage Power Supply Ghid de instalare

Tip
Ghid de instalare
Installation Guide
SIGN244 | A-1020632
Power Supply Features
Supports all 24 VDC Tetra Products
UL: Class 2
IEC: SELV
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
Limited to use in dry and damp locations.
The suitability of rain enclosure shall be determined if
intended for wet location.
The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
Follow all National Electric Codes (NEC) and local codes.
For the latest North American install guides for your product go to: https://products.LED.com/led-signage-lighting
For the latest European install guides for your product go to: https://products.LED.com/eu
BG Българската версия на инструкциите за инсталаця
и информация за безопасност могат да бъдат
намерени на следния адрес: https://products.LED.
com/eu
CS Návod k montáží a bezpečnostní informace v
češtině najdete zde: https://products.LED.com/eu
DA Den danske version af installationsvejledningen
og sikkerhedsoplysninger kan findes på følgende
placering: https://products.LED.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen finden Sie in folgendem
Verzeic: https://products.LED.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των
οδηγιών νγκατάστασης και των πληροφοριών
ασφάλειας στην εξής τοποθεσία: https://products.
LED.com/eu
ES La versión española de las instrucciones de
instalación y la información sobre seguridad puede
encontrarse en la siguiente ubicación: https://
products.LED.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu
FI Asennusohjeiden ja turvallisuustietojen
suomenkielinen versio löytyy seuraavasta paikasta:
https://products.LED.com/eu
FR La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.LED.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://
products.LED.com/eu
HU A telepítési útmutató és a biztnosági információk
magyar nyelvű változata az alábbi címen található:
https://products.LED.com/eu
IT La versione italiana del manuale di installazione
e sicurezza può essere reperita nella seguente
sezione: https://products.LED.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos
informacijos versiją galima rasti šioje vietoje: https://
products.LED.com/eu
LV Uzstādīšanas instrukciju un drošības informāciju
latviešu valodā var atrast šeit: https://products.LED.
com/eu
NL De Nederlandse versie van de installatie-instructies
en veiligheidsinformatie kan op de volgende locatie
worden gevonden: https://products.LED.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w
następującej lokalizacji: https://products.LED.com/eu
PT A versão em Português das instruções de
instalação e das informações de segurança pode
ser encontrada na seguinte localização: https://
products.LED.com/eu
RO Versiunea în limba română a instrucţiunilor de
instalare şi a informaţiilor de siguranţă pot fi găsite
la: https://products.LED.com/eu
SV Ni hittar den svenska versionen
av installationsanvisningarna och
säkerhetsinformationen på följande plats: https://
products.LED.com/eu
SL Previdnostna opozorila in varnostne informacije
so na zadnji strani vodnika za namestitev. Pred
začetkom namestitve izdelka jih skrbno preberite:
https://products.LED.com/eu
SK Slovenskú verziu montažnej príručky a
bezpečnostnŷch instrukcií nájdete na nasledujúcej
lokalite: https://products.LED.com/eu
FOR UL ONLY
EN
LED Systems Power Supply
GEPS24-100U-GLX (120-277 VAC input/24VDC output/100W)
2424
Volt
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Tetra® Power Supply GEPS24-100U-GLX Installation Guide
2
Power Supply Installation
Connect the AC line to the black
or brown (line) and white or
blue (neutral) input wires of the
power supply using suitable wire
connectors.
Connect the supply wire that is
attached to the Tetra LED System
to the red (+) and black or blue (-)
output wires of the power supply
as outlined in the “Electrical
Connections” section of your LED
system’s Installation Instructions.
NOTE: To avoid overloading this
power supply with LED modules,
please refer to the specific module
loading guides.
Input
wires
White or blue
(neutral)
Black or brown
(line)
AC line
To Tetra LED System
Output
wires
Red (+) Black or blue (-)
Mount the power supply. Mounting
the power supply base directly to
a thermally conductive installation
surface can improve thermal
performance.
NOTE: All electrical connections
should be suitably protected
from mechanical damage and the
environment. Seal all connections
exposed to water with electrical
grade self-hardening silicone.
FOR UL ONLY
NOTE: For installation in Canada, a disconnect switch of appropriate rating needs to be placed within 29.5 feet
(9 meters) of primary side of the power supply. The switch voltage rating shall not be less than the branch circuit
voltage. The switch must also support twice the amount of input current.
FOR UL ONLY
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device
for line, neutral and ground connections, in accordance with National Electric Code (NEC) Article 600 and all
local regulations.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Disconnect power at fuse box or circuit breaker before servicing
or installing product.
Properly ground Tetra® power supply.
AC input connections shall be suitably enclosed. The power
supply shall be enclosed or made inaccessible to users during
normal use.
RISK OF FIRE
Minimum power supply spacing to other power supply or other
heat producing component shall be at least 4” (101.6 mm) from
side to side and 1” (25.4mm) from end to end.
Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm2).
Follow all local codes.
Application considerations potentially requiring additional
spacing include high ambient temperature seen by the power
supply, poor contact with a heat dissipating material, inadequate
ventilation, or direct exposure to sun.t
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra®.
Les connexions d’entrée CA doivent être convenablement enfermées. Le bloc
d’alimentation doit être enfermée ou rendue inaccessible aux utilisateurs
pendant l’utilisation normale.
RISQUES D’INCENDIE
L’espacement minimal du bloc d’alimentation par rapport à un autre bloc
d’alimentation ou aux autres composants produisant de la chaleur doit être
au moins 4” (101,6 mm) de chaque côté et 1” (25,4 mm) de bout en bout.
N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
Respectez tous les codes locaux.
Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
OPTIONAL
A Weather Box (GEXNWB2) may be used to house and seal Class 2
connections.
A) Insert wire connectors into weather box. Fill with electrical grade
silicone and close box.
B) Secure the weather box using a #6 or #8 (M2 or M3) screw.
Weather box
can be painted
Light engine
CAUTION / ATTENTION
RISK INJURY
While performing installations described, gloves, safety glasses or
goggles should be worn.
RISQUES DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
WARNING
RISK OF ELECTRIC SHOCK
AC input connections shall be
suitably enclosed.
1 2 3
A B
Tetra® Power Supply GEPS24-100U-GLX Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 3
(Rev 06/20/23)
SIGN244 | A-1020632
Power Supply Specifications
Performance Data Min Typical Max
Input Voltage (VAC) 108 120-277 305
Input Frequency (Hz) 50/60
Input Current (A) 0.35 1.1
THD – 20
PF 0.9 –
Output Voltage (VDC) 24.0 24.5 25.2
Output Current (ADC) 4.0
Output Power (W) 96
Environmental Operating Temperature Range -40°C +25°C +60°C*
Environmental Humidity (non-condensing) 0% 95%
Environmental Storage Temperature Range -40°C +85°C
Environmental Rating IP66 rated: must be protected from direct exposure to the weather
Dimensions 9.5 in. x 1.7 in. x 1.1 in. (241 mm x 43.2 mm x 28 mm)
Conforms to the following standards:
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
*Maximum case temperature is 85°C
Troubleshooting
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
Symptom Solution
All LEDs are OFF The GEPS24-100UGLX features a new built in output overload shutdown feature that automatically resets when the AC supply
is removed and reapplied. So if all letters are off, first verify whether or not the output can be reset by first switching off then
switching back on the AC supply. If the letters do not re-light, then proceed to the following solutions.
Check AC input connection and/or check circuit breaker.
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short circuits. Properly
terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the white wire (-)
of the LED strip to the black or blue wire (-) of the power supply.
Ensure the overall length of the Tetra® LED System does not exceed the maximum load. If so, remove the excess load and cycle
the AC supply to reset the drivers built in overload protection.
Some LEDs
appear dim
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the
LEDs are
not illuminated
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short circuits. Properly
terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the white wire (-)
of the LED strip to the black or blue wire (-) of the power supply.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Tetra 24V GEPS24-100U-GLX Signage Power Supply Ghid de instalare

Tip
Ghid de instalare