Sames Inogun M Manual de utilizare

Tip
Manual de utilizare
Instruction manual
DRT7132
D - 2022/09
Inogun M / Inogun M +
Powder Spray Gun
2Member of Exel group
DRT7132
D - 2022/09
All communication or reproduction of this document, in any form whatsoever and all use or communication of its
contents are forbidden without express written authorisation from Sames.
The descriptions and characteristics mentioned in this document are subject to change without prior notice
© Sames 2020 - translation of the original version
Sames operating manuals are written in French and translated into English, German, Spanish, Italian and Portuguese.
The French version is deemed the official text and Sames will not be liable for the translations into other languages.
3Member of Exel group
DRT7132
D - 2022/09
Services
Certification and referencing
Sames is certified as a training center by the DIRRECTE of the Auvergne Rhône Alpes region under the number 84
38 06768 38.
Our company provides, throughout the year, training courses allowing you to acquire the essential know-how for the
implementation and maintenance of your equipment in order to guarantee its performance in the long term.
A catalog is available on request.
www.sames.com/france/fr/services-training.html
Line audits
As part of a technical assistance program for our customers using Sames equipment, the line audits are intended to
help you optimize and control your production tool.
Our network of experts is continuously trained and qualified to provide our customers with technical expertise on the
liquid or powder installations in which our equipment is integrated. The global environment of the production lines is
taken into account during this technical audit.
A brochure is available for download:
www.sames.com/france/fr/services-service-contract.html
Maintenance program
An annual maintenance program (including or not the consumables to be replaced during each intervention) can be
considered with the partnership of Sames. It is associated with a preventive maintenance plan established during a
first audit visit which details the control points necessary to guarantee the performance of the installed equipment.
www.sames.com/france/fr/services-service-contract.html
Hotline
www.sames.com/france/fr/services-service-contract.html
4Member of Exel group
Inogun M / Inogun M +
1. Health and safety instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
1.1. Configuration of the certified equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.1.1. Applicable Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2. Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3. Meaning of pictograms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4. Precautions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5. Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.6. Regulatory tests to be carried out on the equipment according to standard
EN 50050-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7. Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.1. Ventilation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.2. O-ring seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.3. Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.8. Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2. Description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
3. Characteristics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
3.1. Dimensions (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2. General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3. Air compressed quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4. Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. Diagrams - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18
4.1. Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5. Startup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20
5.1. Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2.1. Installation of an extended nozzle (option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2.2. Procedure for mounting the counter-electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6. Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 23
6.1. Summary table of maintenance operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2. Preventive maintenance plan - PMP 7132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3.1. Procedure A1: Spray gun cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3.2. Procedure A2: Electrode support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.4. Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.1. Procedure B1: Replacement of fixing hook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.2. Procedure B2: Replacement of trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.4.3. Procedure C1: Assembly / Disassembly barrel / handle . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.4.4. Procedure C2: Replacement of HVU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.4.5. Procedure C3: Replacement of air connector o-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.4.6. Procedure D1: Powder duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.4.7. Procedure D2: Replacement of low voltage cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.4.8. Procedure D3: Replacement of control box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7. Troubleshootings- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 38
5Member of Exel group
8. Spare parts list - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 39
8.1. Manual spray guns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8.1.1. Inogun M spray gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8.1.2. Inogun M + spray gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.2. Barrel assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.3. Handle assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.4. Electrode supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8.4.1. Flat spray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8.4.2. Optional: Extended flat spray nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.4.3. Round spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.4.4. Option, Extended round spray nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.5. Counter-electrode assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.6. Spray type conversion kits for extended nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.6.1. Kit for converting a flat spray into a round spray for extended nozzles . . . . . . . . . . . 57
8.6.2. Kit for converting a round spray into a flat spray for extended nozzles . . . . . . . . . . . 58
8.7. Additional equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9. Revision index History - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 60
10. Appendices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 61
10.1. Preventive maintenance plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
10.2. EU and UK declarations of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
6Member of Exel group
DRT7132
D - 2022 /09
1. Health and safety instructions
This manual contains links to the following operating instructions:
see DRT7145 for the Inobox control module.
see DRT7134 for the Inocontroller control module.
1.1. Configuration of the certified equipment
All of these operating manuals define the configuration of the certified equipment.
1.1.1. Applicable Standards
The Inogun M guns has been designed according to standards indicated below:
Canadian Standards:
CSA C22.2 No. 61010-1:12
CSA C22.2 No. 213:19
CSA C22.2 No. 0:20
CSA C22.2 No. 60079-31:15 as a guide
EN 50177:09 / A1:13 as a guide
EN 50500-2:18 as a guide
US Standards:
FANSI/ISA-61010-1: 3rd Ed.
FM3600: 2018
FM3611: 2018
FM 7260: 2018 as a guide
UL60079-31:2nd Ed. as a guide
Installation:
•In Canada, the installation has to be in compliance with the Canadian Electrical Code C22.1 part I, standard
safety for electrical installations.
•In the USA, the installation has to be in compliance with the National Electrical Code NFPA 70.
7
DRT7132
D - 2022 /09
Member of Exel group
1.2. Marking
The Inogun M and Inogun M + guns are classified as type "A-P" according to EN50050-2.
Marking of the guns:
The X sign placed after the EU/UK type examination certificate number indicates that this device is subject to special
operating conditions:
This equipment is designed for an ambient temperature range of 0°C to 40°C.
During installation, the user should take into account that the keypad of the Inobox control module has only
been subjected to a slight mechanical impact (see DRT7145).
•The Inobox control module must be protected from light.
"For Electrostatic Finishing Applications using Class II, spray material when configured
according to 800004734", this statement may be abbreviated to read ‘For Electro. Fin. Appl.
CL. II, Spray Matl. when configured according to 800004734’.
Laser engraving indicating the reference number of
the gun as well as its serial number (the first 2 digits
correspond to the year of manufacture)
8Member of Exel group
DRT7132
D - 2022 /09
* ATEX/UKCA Inogun M configurations
* ATEX/UKCA Inogun M + configurations
Inogun M spray gun - P/N 910030034
High Voltage Unit - P/N 910024679
Electrode support - P/N 910027640
Low voltage cable 6 m- P/N 910029134
Inogun M spray gun - P/N 910030034-12
High Voltage Unit - P/N 910024679
Electrode support - P/N 910027640
Low voltage cable 12 m- P/N 910029182
Inogun M spray gun - P/N 910030034-18
High Voltage Unit - P/N 910024679
Electrode support - P/N 910027640
Low voltage cable 18 m- P/N 910029982
P/N Inogun M
(*)
Inobox
P/N 910029983
P/N 910029984
P/N 910030576
Inocontroller
P/N 910028596
X 910030034 X X
X 910030034-12 X X
X 910030034-18 X X
Inogun M + spray gun - P/N 910031951
High Voltage Unit - P/N 910031489
Electrode support - P/N 910027640
Low voltage cable 6 m- P/N 910029134
Inogun M + spray gun - P/N 910031951-12
High Voltage Unit - P/N 910031489
Electrode support - P/N 910027640
Low voltage cable 12 m- P/N 910029182
P/N Inogun M +
(*)
Inobox
P/N 910029983
P/N 910029984
P/N 910030576
Inocontroller
P/N 910028596
X 910031951 X X
X 910031951-12 X X
9
DRT7132
D - 2022 /09
Member of Exel group
1.3. Meaning of pictograms
Warning electricity Warning
Automatic start-up
Warning
Hot surfaces
Warning
Explosive material
General warning
sign
Warning
High pressure
Warning
Crushing of hands
Warning for
explosive
atmospheres
Warning:
Flammable material
Warning:
Corrosive substance
Warning:
Toxic material
Warning
Harmful products
No access for people
with active implanted
cardiac devices
Wear ear
protection
Wear a face shield
Wear respiratory
protection
Wear safety
footwear
Wear protective
clothing
Wear protective
gloves
Wear head
protection
Opaque eye
protection must be
worn
General mandatory
action sign
Connect an earth
terminal to the
ground
Refer to
Instruction manual
10 Member of Exel group
DRT7132
D - 2022 /09
1.4. Precautions for Use
This document contains information that all operators should be aware of and understand before using the spray
gun. This information highlights situations that could result in serious damage and indicates the precautions that
should be taken to avoid them.
Before any use of the projector, check that all operators:
have previously be trained by the company Sames, or by their distributors registered by them for this
purpose.
have read and understood the user manual and all rules for installation and operation, as laid out
below.
It is the responsibility of the operators’ workshop manager to ensure these two points and it
is also his responsibility to make sure that all operators have read and understood the user
manuals for any peripheral electrical equipment present in the powdering area.
1.5. Warnings
It is imperative that anyone wearing a pacemaker does not use the equipment and does not
enter the projection area.
High voltage can cause the pacemaker to malfunction.
Safety may be jeopardized if this equipment is not operated, disassembled and reassembled in
compliance with the instructions given in this manual and in any European Standard or national
safety regulations in force.
Equipment performance is only guaranteed if original spare parts distributed by Sames are
used.
To guarantee an optimal assembly, spare parts must be stored in a temperature close to their
temperature of use. Should the opposite occur, a sufficient waiting time must be observed
before the installation, so that all the elements are assembled in the same temperature.
This equipment is intended for spraying powder paint only.
11
DRT7132
D - 2022 /09
Member of Exel group
This equipment must only be used in powdering locations according to standard EN 50050-2
and EN 16985. The equipment has to be used only within ventilated in order to reduce risks for
the health of the operators, fire or explosion. The efficiency of the extraction ventilation
system has to be daily checked.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-proof electrical
equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation resistance measured
must not exceed 100 MΩ.
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the insulation resistance
measured must not exceed 100 MΩ.
3 Using individual protection equipment will limit the risks of contact and/or inhalation of toxic product, gas,
vapours, fog or dusts that can be produced while using the equipment. The user has to follow the coating
product manufacturer’s recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for personnel (see: safety
data sheets for the products used). The pressure coating material or compressed air must not be directed at
people or animals.
5 The parts to be painted must have a resistance to earth less than or equal to 1 MΩ (measurement voltage of
at least 500V or 1000V) (§6.2.2.4 in Standard EN 50050-2). This must be checked regularly.
6 All conductive structures such as floors, powder spray station walls, ceilings, barriers, barriers, parts to be
painted, powder dispensing tank placed in or near the work area and the ground terminal of the electro-
pneumatic control module must be electrically connected to the grounding system for protecting the power
supply.
7 The floor on which the operator works must be dissipative (bare concrete floor or metal grating). Never cover
the floor with an insulating covering. In potentially explosive locations, floor assemblies must be dissipative in
accordance with EN 61340-4-1.
8 Switch off the power supply to the Inobox before connecting the Inogun M guns.
Before disconnecting the gun, cut off the power supply to the Inobox (otherwise a malfunction may occur).
9 IIt is essential to properly ventilate the spray booths to avoid any powder output and to ensure a powder
concentration below the lower explosive limit (LEL). The associated equipment must be placed outside the
hazardous areas and its commissioning must be controlled by the operation of the cabin suction fan.
10Never point the gun at a person or animal.
11Powder spraying must be carried out in front of a ventilated station provided for this purpose. The activation of
the Inobox must be controlled by the operation of the ventilation system. The correct operation of the drive
must be checked once a week.
12The ambient operating temperature must be between 0 and 40°C.
13The electrostatic powder spraying equipment must be maintained regularly in accordance with the indications
and instructions given by Sames.
Repairs must be carried out in strict accordance with these instructions.
12 Member of Exel group
DRT7132
D - 2022 /09
14The electrostatic powder spraying equipment should only be operated if it is in perfect condition. Damaged
equipment must be removed from service immediately and repaired.
15Before cleaning the projectors or doing any other work in the spray area, the power supply to the high-voltage
generator must be disconnected, protected against restarting and the HV circuit protected. (projector)
discharged to ground.
Cleaning must be carried out in mechanically ventilated areas.
16Inside the booth it is forbidden to use naked flames, glowing objects or devices likely to produce sparks.
It is also forbidden to store flammable products, or recipients that have contained them, in the vicinity of the
booth.
The surrounding area must be kept clear and clean.
17In the explosive zone, it is forbidden to use non-certified electrical or non-electrical equipment such as
electrical extension cords, multi-sockets, switches, etc.
A warning sign in a language understood by the operator, summarizing the safety rules described above, must be
prominently displayed in the vicinity of the powder spray station.
1.6. Regulatory tests to be carried out on the equipment according to standard EN 50050-2
The tests must be carried out on the spraying equipment. The tests must be carried out by competent personnel
and include the tests described below (see § 6.2.3 table 1 in standard EN 50050-2).
(*) Intervals depend on operating and local conditions.
1.7. Important recommendations
1.7.1. Ventilation
Do not start the powder application with the Inogun M spray gun until the spray booth ventilation system is
switched on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a
risk of fire, poisoning or irritation.
1.7.2. O-ring seals
Use the seals recommended in this manual.
1.7.3. Ambient temperature
The spray gun is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C.
The storage temperature must never exceed +60°C.
Type of test Requirements
Grounding measures Weekly
Forced ventilation interlock and manual electrostatic spraying
equipment Annual
Checking manual electrostatic spraying equipment for damage Weekly
13
DRT7132
D - 2022 /09
Member of Exel group
1.8. Guarantee
Under the guarantee, which applies only to the buyer, Sames agrees to repair operating faults resulting from a
design fault, materials or manufacture, under the conditions set out below.
The guarantee claim must define the exact nature of the fault concerned, in writing.
The Sames guarantee only covers equipment that has been serviced and cleaned according to standard procedures
and our own instructions, that has been fitted with parts approved by Sames or that has not been modified by the
customer.
More precisely, the guarantee does not cover damage resulting from:
the customer's negligence or inattention,
incorrect use,
failure to follow procedures,
use of a control system not designed by Sames or a Sames control system modified by a third party without
written permission from an authorized Sames technical agent,
accidents such as: collision with external objects, or similar events,
flooding, earthquake, fire or similar events,
use of seals not complying with Sames recommendations,
pollution of air circuits by fluids or substances other than air.
The Sames guns type Inogun M / M + are covered by a warranty (refer to the general sales conditions for its
application).
The guarantee does not apply to wearing parts such as electrode supports, deflectors, powder tube, seals, etc...
The guarantee will take effect from the date of the first start-up or of the provisional acceptance report.
Under no circumstances, either in the context of this guarantee or in other contexts, will Sames be held responsible
for physical injury or intangible damage, damage to brand image and loss of production resulting directly from its
products.
14 Member of Exel group
DRT7132
D - 2022 /09
2. Description
The Inogun M guns is a manual gun designed to project powder by means of a high voltage unit integrated in the
gun which delivers up to 100 kV and 110 μA.. It is associated with an Inobox or Inocontroller control module which
controls both the high voltage and the powder flow rate of the gun connected to it. These two inseparable elements
constitute a manual powder coating equipment.
This new gun integrates a dual control by the + and - keys located on the rear keyboard which allow to adjust powder
flow, current or change of the program according to the selection on the Inobox module (see DRT7145) when
pressing the keyboard.
Item Description
1Fastening hook
2Barrel
3Nozzle nut
4Flat spray deflector
5Trigger
6High voltage presence LED
7Low voltage cable
8Powder fitting
9Handle
10 Control box
1 2 3 4
5
78
9
10
6
15
DRT7132
D - 2022 /09
Member of Exel group
3. Characteristics
3.1. Dimensions (mm)
mm inches
A271 10.67
B339 13.35
C50 1.97
A
B
C
DES07478
16 Member of Exel group
DRT7132
D - 2022 /09
3.2. General characteristics
3.3. Air compressed quality
Characteristics of compressed air supply according to the standard NF ISO 8573-1:
*: Values are given for a temperature of 20 °C (68 °F) at an atmospheric pressure of 1 013 mbar.
Non-compliance with these characteristics may result in incorrect operation of the
Inocontroller or Inobox control modules.
A 5 μm filter must be installed upstream of the compressed air supply of the Inocontroller or
Inobox control modules. This filter is sized according to the size of the installation.
Sames recommends using a filter of the type indicated in the section (see § 8.7 page 59). In the
event of damage to the equipment due to the use of polluted air, the warranty may not be
applied.
Inogun M / M+ spray guns
Ambient temperature during operations 0° to 40°C
Maximum operating altitude 2000 m
Weight of the gun (without cable and hose) 565 g
Maximum output voltage negative HVU -100 kV (0 kV, -10 kV)
Maximum output voltage positive HVU +100 kV (0 kV, -10 kV)
Max. output current 110 μA (+ or - 10 μA)
High voltage unit capacity 60 pF
Supply pressure 7 bar +/- 1 bar
Maximum powder flow rate 24 kg/h
Maximum relative humidity of 80% for temperatures up to 31°C, and
linear decrease to 50% relative humidity at 40°C. maximum 80% non-condensing
Storage / Transport
Storage duration Max. 2 years
Minimum/maximum storage temperature -10°C + 45°C
Humidity 95% non-condensing
Min. pressure 750 mBar
Exposure to UV radiation Stored away from light
Exposure to ionizing radiation Not admitted
Maximum dew point at 6 bar (87 psi) Class 4 i.e + 3°C (37°F)
Maximum particle-size of solid pollutants Class 3 i.e 5 μm
Maximum oil concentration Class 1 i.e 0,01 mg/m03 *
Maximum concentration of solid pollutants Class 3 i.e 5 mg/m03 *
17
DRT7132
D - 2022 /09
Member of Exel group
3.4. Operating principle
By pulling the gun trigger, the power supply and electrical charging of the powder is triggered.
Keys et on the back keyboard are used to adjust:
Powder flow when simultaneously pressing the trigger and the keyboard.
The current or change of the program according to the selection on the Inobox module (see DRT7145) when
pressing the keyboard.
18 Member of Exel group
DRT7132
D - 2022 /09
4. Diagrams
Synoptic of an installation with Inogun M and Inobox
Synoptic of an installation with Inogun M and Inocontroller
Inogun MPowder suctionAir supply
Vibrator Power fluidisationSupply
Module of
network communication
PLC + 24VDC LPS
Inogun MPowder suctionAir supply
19
DRT7132
D - 2022 /09
Member of Exel group
The Inogun M guns are connected to the Inobox or Inocontroller control module.
This module provides the low-voltage and high-frequency power supply necessary for the operation of the
integrated high-voltage unit and the air distribution and regulation.
4.1. Electrical connections
Pin
10-pin
connector
Inobox side
Pin
3-pin
connector
Inogun M side
Pin
5-pin
connector
Inogun M side
1HVU 1-Primary 1 HVU 1-Primary
2Trigger 1Trigger
3HVU 2-Primary 2 HVU 2-Primary
4Anode LED 2 Anode LED
5Ground 4 Ground
6+ Button 3+ Button
7I HVU return 3 I HVU return
8- Button 5- Button
9 10kW resistor
10
HVU 1-Primary
+ Button
HVU 2-Primary
-
Button
Ground
Anode Led
I HVU return
Trigger
1
2
6
5
4
7
3
9
8
10
10 - pin male connector
M16
1
2
3
1
3
2
4
5
Yellow
Red
White
Grey
Green
Black
Brown
5- pin female
connector
3- pin female
connector
Blue
Yellow
Red
White
Grey
Green
Black
Brown
Blue
360° shielding connection
through the ferrule of
the M16 connector
HVU
Control Box
DES07803
The 2 screws will be
connected by a screw
in the base plate.
Shield to be soldered
on lug
20 Member of Exel group
DRT7132
D - 2022 /09
5. Startup
5.1. Tools
Additional tools and accessories required:
The tools listed below should be available for product installation and maintenance operations.
Flat screwdriver (0.6x3.5).
2- Pozidriv screwdriver.
Torque wrench.
Open-end wrench (15 mm).
Multigrip pliers.
P/N Description Qty Unit of sale
240000301 Seal extractor tool 1 1
P/N Description Qty Unit of sale
H1GMIN017 White Vaseline (100 ml) 1 1
H1GSYN037 Dielectric grease for high voltage unit (100 ml) 1 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69

Sames Inogun M Manual de utilizare

Tip
Manual de utilizare

în alte limbi