Sames Inocart NDT/HF Manual de utilizare

Categorie
Pulverizator de vopsea
Tip
Manual de utilizare
Instruction manual
DRT7161
B - 2023/10
Inocart NDT - Inocart HF
Cart for powder gun
2
Member of Exel group DRT7161
B - 2023/10
All communication or reproduction of this document, in any form whatsoever and all use or communication of its
contents are forbidden without express written authorisation from Sames.
The descriptions and characteristics mentioned in this document are subject to change without prior notice
© Sames 2020 - Translation of the original instruction manual
3
Member of Exel group DRT7161
B - 2023/10
Services
Certification and referencing
Sames is certified as a training center by the DIRRECTE of the Auvergne Rhône Alpes region under the number 84
38 06768 38.
Our company provides, throughout the year, training courses allowing you to acquire the essential know-how for the
implementation and maintenance of your equipment in order to guarantee its performance in the long term.
A catalog is available on request.
www.sames.com/france/en/services-training.html
Line audits
As part of a technical assistance program for our customers using Sames equipment, the line audits are intended to
help you optimize and control your production tool.
Our network of experts is continuously trained and qualified to provide our customers with technical expertise on the
liquid or powder installations in which our equipment is integrated. The global environment of the production lines is
taken into account during this technical audit.
A brochure is available for download:
www.sames.com/france/en/services-service-contract.html
Maintenance program
An annual maintenance program (including or not the consumables to be replaced during each intervention) can be
considered with the partnership of Sames. It is associated with a preventive maintenance plan established during a
first audit visit which details the control points necessary to guarantee the performance of the installed equipment.
www.sames.com/france/en/services-service-contract.html
Hotline
www.sames.com/france/en/services-service-contract.html
4
Member of Exel group
Inocart NDT - Inocart HF
1. Health and safety instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
1.1. Configuration of the certified equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2. Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3. Meaning of pictograms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4. Simplified analysis of potential ignition sources according to Standard
EN 80079-36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.5. Precautions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.6. Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.7. Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.1. Ventilation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.2. O-ring seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.3. Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.7.4. Sound level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.8. Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2. Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
2.1. General overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3. Characteristics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
3.1. General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2. Air compressed quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4. Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
5. Start up- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17
5.1. Specific tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3. Use of Inocart NDT or HF equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3.1. Powder application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6. Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19
6.1. Maintenance summary table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2. Preventive maintenance plan - See PMP 7161 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3.1. Procedure A: Cleaning the cart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3.2. Procedure B: Cleaning of the injection air check valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.3.3. Procedure C: Dump of tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.4. Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.4.1. Procedure D1: Replacement of filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.4.2. Procedure D2: Replacement of vibrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7. Spare parts list - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 24
7.1. Equipment Inocart NDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.2. Equipment Inocart HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.2.1. Inocart NDT/HF cart, Europe and US versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8. Revision index History - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29
9. Appendices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 30
5
Member of Exel group
9.1. Maintenance preventive plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.2. EU and UK declarations of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6
Member of Exel group DRT7161
B - 2023/10
1. Health and safety instructions
This manual contains links to the following operating instructions:
see DRT7132 for the Inogun M/M + spray gun.
see DRT7145 for the Inobox control module.
see DRT7169 for the NDT Pressure tank.
see DRT7170 for the HF Pressure tank.
1.1. Configuration of the certified equipment
All of these operating manuals define the configuration of the certified equipment.
1.2. Marking
The
Inocart NDT/HF
is classified as category 3 according to the ATEX 2014/34/EU and SI 2016 No. 1107 directives
and is designed for use in zone 22.
The mode of protection applied is "safety by design".
DES07871
DES07872
7
Member of Exel group DRT7161
B - 2023/10
ATEX / UKCA Inocart NDT configurations
ATEX / UKCA Inocart HF configurations
Inocart NDT 6m Europe version - P/N 910030369
Inogun M 6m - P/N 910030034
NDT pressure tank - P/N 910030917
Vibrator - P/N 910030011
Inocart NDT 12m Europe version- P/N 910030369-12
Inogun M 12m - P/N 910030034-12
NDT pressure tank - P/N 910030917
Vibrator - P/N 910030011
Inocart NDT 6m US version - P/N 910030908
Inogun M 6m - P/N 910030034
NDT pressure tank - P/N 910031523
Vibrator - P/N 910030896
Inocart NDT 12m US version - P/N 910030908-12
Inogun M 12m - P/N 910030034-12
NDT pressure tank - P/N 910031523
Vibrator - P/N 910030896
Inocart NDT
P/N Inobox NF
P/N 910030576
X 910030369 X
X 910030369-12 X
X 910030908 X
X 910030908-12 X
Inocart HF 6m Europe version - P/N 910030367
Inogun M 6m - P/N 910030034
HF Pressure tank - P/N 910031405
Vibrator - P/N 910030011
Inocart HF 12m Europe version - P/N 910030367-12
Inogun M 12m - P/N 910030034-12
HF Pressure tank - P/N 910031405
Vibrator - P/N 91003001
Inocart HF 6m US version - P/N 910031513
Inogun M 6m - P/N 910030034
HF Pressure tank - P/N 910031512
Vibrator - P/N 910030896
Inocart HF 12m US version - P/N 910031513-12
Inogun M 12m - P/N 910030034-12
HF Pressure tank - P/N 910031512
Vibrator - P/N 910030896
P/N
Inocart HF
Inobox NF
P/N
910030576
X 910030367 X
X 910030367-12 X
X 910031513 X
X 910031513-12 X
8
Member of Exel group DRT7161
B - 2023/10
1.3. Meaning of pictograms
Warning
electricity
Warning
Automatic start-up
Warning
Hot surface
Warning
Explosive material
General warning
sign
Warning
High pressure
Warning
Crushing of hands
Warning for
explosive
atmospheres
Warning
Flammable
material
Warning
Corrosive
subtance
Warning
Toxic material
Warning
Harmful products
No access for
people with active
implanted cardiac
devices
Wear ear
protection
Wear a face
shield
Wear respiratory
protection
Wear safety
footwear
Wear protective
clothing
Wear protective
gloves
Wear head
protection
Opaque eye
protection must
be worn
General mandatory
action sign
Connect an
earth terminal
to the ground
Refer to
Instruction manual
9
Member of Exel group DRT7161
B - 2023/10
1.4. Simplified analysis of potential ignition sources according to EN 80079-36
1.5. Precautions for Use
This document contains information that all operators should be aware of and understand before using the carts
Inocart. This information highlights situations that could result in serious damage and indicates the precautions that
should be taken to avoid them.
Before any use of the Inobox control module, check that all operators:
• have previously be trained by the company Sames, or by their distributors registered by them for this
purpose.
• have read and understood the user manual and all rules for installation and operation, as laid out
below.
It is the responsibility of the operators’ workshop manager to ensure these two points and it is also his
responsibility to make sure that all operators have read and understood the user
manuals for any peripheral electrical equipment present in the powdering area.
1.6. Warnings
It is imperative that anyone wearing a pacemaker does not use the equipment and does not
enter the projection area.
High voltage can cause the pacemaker to malfunction.
This equipment may be hazardous if it is not used, disassembled and reassembled in
accordance with the rules indicated in this manual and in any applicable European Standard or
national safety regulations.
This equipment is intended for spraying powder paint only.
Risk of ignition Measures applied to prevent the source of
ignition from becoming effective
Potential source of
ignition
Description / Main cause (What are the conditions
causing the risk of ignition) Description of the measure applied
Hot surface Vibrator heating in vibrating table version Maximum vibrator surface temperature of
100°C
Static electricity
Internal electrostatic discharge in powder hose Antistatic hose
Electrostatic discharge on the cart Equipotentiality of the metal parts + earthing
Electrostatic discharge on the pressure tank Equipotentiality of the metal parts + earthing
10
Member of Exel group DRT7161
B - 2023/10
Equipment performance is only guaranteed if original spare parts distributed by Sames
are used.
To guarantee an optimal assembly, spare parts must be stored in a temperature close to their
temperature of use. Should the opposite occur, a sufficient waiting time must be observed
before the installation, so that all the elements are assembled in the same temperature.
Equipment should only be used in well-ventilated areas to reduce health, fire and explosion
hazards. The effectiveness of the exhaust ventilation system should be checked daily.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-
proof electrical equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation resistance measured
must not exceed 100 MΩ.
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the insulation resistance
measured must not exceed 100 MΩ.
3 Using individual protection equipment will limit the risks of contact and/or inhalation of toxic product, gas, va-
pours, fog or dusts that can be produced while using the equipment. The user has to follow the coating product
manufacturer’s recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for personnel (see: safety
data sheets for the products used). The pressure coating material or compressed air must not be directed at
people or animals.
5 All conductive structures such as floors, powder spray station walls, ceilings, barriers, barriers, parts to be paint-
ed, powder dispensing tank placed in or near the work area and the ground terminal of the electro-pneumatic
control module must be electrically connected to the grounding system for protecting the power supply.
6 The floor on which the operator works must be dissipative (bare concrete floor or metal grating). Never cover
the floor with an insulating covering. In potentially explosive locations, floor assemblies must be dissipative in
accordance with EN 61340-4-1.
7 Switch off the power supply to the Inobox before connecting the Inogun M gun.
Before disconnecting the gun, cut off the power supply to the Inobox (otherwise a malfunction may occur).
8 Never point the gun at a person or animal.
9 Powder spraying must be carried out in front of a ventilated station provided for this purpose. The activation of
the Inobox must be controlled by the operation of the ventilation system.
The correct operation of the drive must be checked once a week.
10The ambient operating temperature must be between 0 and 40°C.
11The electrostatic powder spraying equipment must be maintained regularly in accordance with the indications
and instructions given by Sames. Repairs must be carried out in strict accordance with these instructions.
11
Member of Exel group DRT7161
B - 2023/10
12 The electrostatic powder spraying equipment should only be operated if it is in perfect condition. Damaged
equipment must be removed from service immediately and repaired.
13 Before cleaning the projectors or doing any other work in the spray area, the power supply to the high-voltage
generator must be disconnected, protected against restarting and the HV circuit protected. (spray gun) dis-
charged to ground.
Cleaning must be carried out in mechanically ventilated areas.
14 In the explosive zone, it is forbidden to use non-certified electrical or non-electrical equipment such as elec-
trical extension cords, multi-sockets, switches, etc.
15 The cart as well as the tanks must obligatorily be placed and used outside the explosive zone.
16 It is imperative to connect the earth terminal of the cart to the earth terminal of the powder coating installation
(or of the powder coating booth) in order to ensure the safety of the operators and the correct operation of the
powder coating equipment.
17 Any filling of the tank with powder must be done in a ventilated area provided for this purpose and under no
circumstances in the vicinity of the cart.
18 The tank must be earthed at the terminal provided for this purpose.
19 If the tank is used outside the cart, it is imperative that it is electrically connected to earth via its body.
20 The cart must under no circumstances be used to carry or transport loads other than the pressure tank.
A warning sign in a language understood by the operator, summarising the safety rules described above, must be
prominently displayed in the vicinity of the powder spray station.
12
Member of Exel group DRT7161
B - 2023/10
1.7. Important recommendations
1.7.1. Ventilation
Do not start the powder application with the Inogun M spray gun until the spray booth ventilation system is
switched on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a
risk of fire, poisoning or irritation.
1.7.2. O-ring seals
Use the seals recommended in this manual.
1.7.3. Ambient temperature
The equipment is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C
(32 °F to 104 °F)
The storage temperature must never exceed +60°C.
1.7.4. Sound level
The sound pressure level generated by Inocart NDT / HF carts is equal to 70 dBA under the specified conditions of
use.
Conditions of measurement:
The equipment was put into operation at maximum characteristics, the measurements were carried out at different
positions at 1 m from the cart without powder in the Powder laboratory at the Sames site in Meylan, France.
Method of measurement:
The acoustic pressure level, continuous, equivalent, weighted (70 dBA) is given in LEQ value, measured for
observation periods of at least 30 seconds.
13
Member of Exel group DRT7161
B - 2023/10
1.8. Guarantee
Under the guarantee, which applies only to the buyer, Sames agrees to repair operating faults resulting from a de-
sign fault, materials or manufacture, under the conditions set out below.
The guarantee claim must define the exact nature of the fault concerned, in writing.
The Sames guarantee only covers equipment that has been serviced and cleaned according to standard procedures
and our own instructions, that has been fitted with parts approved by Sames or that has not been modified by the
customer.
More precisely, the guarantee does not cover damage resulting from:
the customer's negligence or inattention,
incorrect use,
failure to follow procedures,
use of a control system not designed by Sames or a Sames control system modified by a third party without
written permission from an authorized Sames technical agent,
accidents such as: collision with external objects, or similar events,
flooding, earthquake, fire or similar events,
use of seals not complying with Sames recommendations,
pollution of air circuits by fluids or substances other than air.
The Sames carts type Inocart NDT and Inocart HF are covered by a warranty (refer to the general sales conditions
for its application).
The guarantee does not apply to wearing parts such as electrode supports, deflectors, powder tube, seals, etc...
The guarantee will take effect from the date of the first start-up or of the provisional acceptance report.
Under no circumstances, either in the context of this guarantee or in other contexts, will Sames be held responsible
for physical injury or intangible damage, damage to brand image and loss of production resulting directly from its
products.
14
Member of Exel group DRT7161
B - 2023/10
2. Introduction
2.1. General overview
The Inocart is a space-saving and easy-to-handle cart designed for manual powder application.
The Inocart cart is equipped with the Inobox control module at the ideal height and with a inclination that can be
customized by the operator for a perfect reading of the information, as well as the Inogun M gun that is installed at
the right height on either side of the cart.
Equipped with several air quick couplers, its use and maintenance are optimized compared to previous generations.
Available in two versions:
Inocart NDT: Equipped with a NDT pressure tank with a capacity of 15 litres. It is used for very low flow rates
(maximum 30 gr/min with dry penetrant powder).
Inocart HF: Equipped with an NDT pressure tank with a capacity of 24 litres, it is used for high flow rates.
Inocart NDT / HF equipment
1 Inobox NF control module
2 NDT or HF pressure tank
3Pressure tank support
4Vibrator
5 Inogun M spray gun
1
3
4
5
2
15
Member of Exel group DRT7161
B - 2023/10
3. Characteristics
3.1. General characteristics
The structure of the cart makes it possible to place:
•In the NDT version: a pressure tank that can hold approximately 15 liters of fluidised powder (i.e. approximate-
ly 5 to 7 kg of powder depending on density).
•In HF version: a pressure tank that can contain about 24 liters of fluidised powder (i.e. about 10 to 12 kg of
powder depending on density).
3.2. Air compressed quality
Characteristics of compressed air supply according to the standard NF ISO 8573-1:
*: Values are given for a temperature of 20 °C (68 °F) at an atmospheric pressure of 1 013 mbar
The filter installed on the Inocart NDT/HF is used to guarantee the correct operation of the equipment, in case of
accidental non-compliance with the network compressed air filtration recommendations.
(*) A pressure higher than 8 bar can cause malfunctions.
Total equipment consumption:
4. Operation
The NDT and HF carts mainly consist of a cart, an Inobox NF module, an NDT or HF pressure tank depending on
the version and an Inogun M gun.
The Inogun M gun allows to:
spray powder paint on an earthed part.
electrically charge the powder so that it adheres to the part to be powdered.
The electric charge of the powder is ensured by an electrode located at the end of the nozzle. This electrode is
brought to high voltage by a high voltage unit integrated in the gun barrel. The high-voltage unit is even supplied
with low-voltage current by the Inobox NF control module.
Inocart NDT Inocart HF
Dimensions of the cart (H x W x D) 1230 x 490 x 720 mm 1230 x 490 x 720 mm
Approximate weight (without powder) 40 kg 45 kg
Maximum dew point at 6 bar (87 psi) Class 4 i.e + 3°C (38°F)
Maximum particle-size of solid pollutants Class 3 i.e 5 μm
Maximum oil concentration Class 1 i.e 0,01 mg / m03 *
Maximum concentration of solid pollutants Class 3 i.e 5mg / m03 *
Inocart" equipment air supply pressure 7 bar +/- 1 bar (*)
NDT version Injection from 0 to 100 and fluidisation at 50 85 l/min max
HF version Injection at 80 and fluidisation at 43 on Inobox 85 l/min whatever the position of the shutter
16
Member of Exel group DRT7161
B - 2023/10
The powder paint is deposited in the NDT or HF pressure tank:
The injection air (check valve Item 5) is used to pressurize the NDT or HF pressure tank.
The powder contained in the tank (Item 3) is fluidized at the fluidizing cup by means of air (fitting on the
fluidizing cup 6) passing through the porous cone 7).
The electric vibrator (4) prevents powder accumulation in the porous cone.
The air jet from the injector carries the powder towards the ejector tube.
In NDT version: The shutter (2) which more or less closes the powder ejector tube must be set to "0" at start-
up. The dry developer flow rate is adjusted using the injection air on the Inobox control module or directly on
the gun using the + and - keys. If the flow rate is not sufficient when the injection parameter is at 100, it can be
increased by opening the shutter (2) slightly using the lever (1) located on the cover.
In the HF version: On the Inoboxcontrol module, the injection setpoint must be set to 80 and the fluidisation
to 43. The powder flow rate is adjusted using the lever (1) on the cover. This pilots the shutter (2) which more
or less closes the powder ejector tube. The adjustment can be refined by changing the injection air set point on
the Inobox module or directly on the gun.
In no case should the maximum filling height of the tank exceed a threshold of 10 cm below
the end of the ejector tube.
10 cm
2
4
5
3
1
6
7
17
Member of Exel group DRT7161
B - 2023/10
5. Start up
5.1. Specific tool
None.
5.2. Installation
The Inocart NDT or HF carts are delivered assembled.
Step 1: Connect the ground cable of the cart to a
conductive and earthed part of the spray booth; the
ground potential must be identical to that of the part
to be powdered.
Step 1:: Attach the tank support to the base of the
cart using the 4 screws 8 x 25 provided.
Step 2: Connect the air supply and ground wire to
the tank:
Gun powder supply hose (1)
Green/yellow wire: ground (2).
Hose 4/6: dilution air for fluidization (3)
Hose 6/8: injection air (4).
Step 3: Connect the 5 m earthing cable to an
electrically earthed part of the application booth.
Step 4: Connect the Inobox's power supply plug.
Step 5: Connect the electrode blowing hose on
the Inobox module side and on the gun side.
The cart is ready to start the powder application.
2
3
4
1
18
Member of Exel group DRT7161
B - 2023/10
5.3. Use of Inocart NDT or HF equipment
5.3.1. Powder application
As the equipment has already been installed according to the safety rules (see § 1 page 6) and the instructions given
(see § 5.2 page 17), follow the steps described below:
Step 1: Connect the ground cable of the cart to a conductive and earthed part of the spray booth; the ground
potential must be identical to that of the part to be powdered.
Step 2: Electrically and pneumatically power the equipment.
Step 3: Put powder in the pressure tank and close the lid with the clamps.
Tank under pressure in operation.
Step 4: Switch on the Inobox control module (see DRT7145) (ON button on the front of the module.
Configure the Inobox NF control module (see DRT7145), for pressure tank operation.
The fluidizing outlet at the rear of the module must be plugged.
Step 5: Choose the appropriate high-voltage feature or create a custom program.
Step 6: Point the gun nozzle towards the booth and the part to be powdered and press the trigger.
5.3.1.1. In Non destructive Testing Powder (NDT) use
The NDT pressure tank is equipped with 2.7mm injector, 2.7mm ejector and 6mm inner diameter hose.
Close the NDT tank shutter fully (position 0).
Set the fluidization to setpoint 50. The dry developer flow rate can then be adjusted on the Inobox module or
directly on the gun by varying the injection parameter (0 to 100). If the flow rate is not sufficient, the control
shutter can be opened slightly.
5.3.1.2. In powder coating (HF) use
This equipment can be used for the application of difficult powders, very high flow rates can then be achieved.
However, the acceptable use limit of a conventional electrostatic gun (charge capacity) is reached at 15kg/h of
powder (250g/min).
The HF pressure tank is equipped with an ejector D: 1.7 mm, a 9/13 EVA hose and a suitable powder fitting
(see DRT7170).
Set the injection parameter (on the Inobox module or directly on the gun) to 80 and the fluidization to 43.
Then adjust the powder flow rate by adjusting the position of the shutter on the pressure tank.
As an indication, with 6 m of 9mm hose and with a standard powder:
Shutter position 123 4 5
Powder flow rate (kg/h) 61444 70 80
19
Member of Exel group DRT7161
B - 2023/10
6. Maintenance
Note: This paragraph applies only to the maintenance of the Inocart cart.
For specific maintenance of the gun (see DRT7132) and the Inobox control module (see DRT7145).
Disconnect the power supply to the control module before connecting the gun. Before
disconnecting the gun, switch off, cut off the power supply to the control module (otherwise
a malfunction may occur).
6.1. Maintenance summary table
The soiling and wear of the different elements of the Inocart carriage caused by the passage of the powder depends
on the nature of the powder and the operating conditions.
Therefore, the periodicity of maintenance indicated in the procedures below is only indicative. The user will have to
create his own maintenance range as he uses the Sames equipment.
Procedure Detail Duration Frequency
Cleaning
ACleaning of the cart 2 min 8 Hours
BCleaning of the injection air check valve 2 min -
CDump of tank 5 min 8 Hours or at each
color change
Replacement
DD1 Replacement of filter 10 min -
D2 Replacement of vibrator 30 min -
20
Member of Exel group DRT7161
B - 2023/10
6.2. Preventive maintenance plan - See PMP 7161
The objective of the proposed preventive maintenance plan is to define in an exhaustive way, the verification,
replacement and cleaning actions of the installed Sames equipment.
In order to anticipate breakdowns and malfunctions that may be due to technical deviations of the installation, the
preventive maintenance plan attached to the user manual lists the routine maintenance operations necessary for
better comfort in the use of the production tool.
Depending on the skills, area of responsibility and accreditation of each person involved, the preventive maintenance
plan can be divided into two distinct levels: level 1 and level 2:
Level 1: first level maintenance is essentially composed of visual control and cleaning operations of some
elements of the equipment. To limit this level, only the specific tools supplied with the equipment will be used.
This first level of maintenance is generally taken care of by paint operators or installation managers.
Level 2: second level maintenance completes the first level by more complex dismantling operations requiring
electrical engineering tools.
This second level is generally handled by the factory maintenance department.
6.3. Cleaning
6.3.1. Procedure A: Cleaning the cart
Before any intervention, refer to the health and safety instructions (see § 1.6 page 9).
Always wear safety glasses.
When handling powder, wear gloves of a suitable resistant material
Work in a well ventilated area.
All cleaning operations should only be carried out using compressed air at a maximum pressure
of 2.5 bar, a cloth or possibly a brush.
Never use water or solvents to clean the equipment.
Clean the complete Inocart cart with compressed air every 8 hours.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Sames Inocart NDT/HF Manual de utilizare

Categorie
Pulverizator de vopsea
Tip
Manual de utilizare

în alte limbi