Beretta Ciao S 24 R.S.I. Installer And User Manual

Tip
Installer And User Manual

Acest manual este potrivit și pentru

EN
ES
PT
HU
RO
DE
SL
EN
ES
PT
HU
RO
DE
SL
0694
0694BT1921
F
Ciao S complies with the basic requirements of the following Directives:
- Gas Appliance Directive 2009/142/EEC;
- EfciencyDirective92/42/EEC;
- ElectromagneticCompatibilityDirective2004/108/EEC;
- Low Voltage Directive 2006/95/EEC
therefore t bears the EC marking
F
Installer manual-User manual......................................................................3
Technical data............................................................................................ 12
Control panel ............................................................................................. 91
Appliance functional elements ...................................................................93
Hydrauliccircuit .........................................................................................95
Wiring diagrams.........................................................................................99
Circulator residual head...........................................................................103
Ciao S est conforme aux prescriptions essentielles des Directives suivantes:
- Directive Gaz 2009/142/CEE;
- Directive Rendements 92/42/CEE;
- Directive Compatibilité électromagnétique 2004/108/CEE;
- Directive Basse tension 2006/95/CEE,
et peut donc être estampillée CE.
Manuel d’installation-Manuel de l'utilisateur .............................................. 14
Données techniques ..................................................................................23
Panneau de commande ............................................................................91
Éléments fonctionnels de la chaudière ......................................................93
Circuithydraulique .....................................................................................95
Schémas électriques ................................................................................. 99
Prévalence résiduelle du circulateur........................................................103
Ciao S es conforme a los requisitos esenciales de las siguientes Directivas:
- Directiva Gas 2009/142/CEE;
- Directiva Rendimientos 92/42/CEE;
- Directiva Compatibilidad Electromagnética 2004/108/CEE;
- Directiva baja tensión 2006/95/CEE
yporlotantoestitulardelmarcadoCE
Manual para el instalador - Manual para el usuario .................................. 25
Datos técnicos ........................................................................................... 34
Panel de mandos.......................................................................................91
Elementos funcionales del aparato ...........................................................93
Circuito hidráulico ...................................................................................... 95
Esquemas eléctricos .................................................................................99
Altura de carga residual del circulador .................................................... 103
A Ciao S é conforme aos requisitos essenciais das seguintes Directivas:
- Directiva gás 2009/142/CEE;
- Directiva Rendimentos 92/42/CEE;
- Directiva Compatibilidade Electromagnética 2004/108/CEE;
- Directiva baixa tensão 2006/95/CEE
portanto, é titular de marcação CE
Manual do instalador-Manual do utilizador ................................................ 36
Dados técnicos .......................................................................................... 45
Painel de comando ....................................................................................91
Elementos funcionais do aparelho ............................................................93
Circuito hidráulico ...................................................................................... 95
Esquemas eléctricos .................................................................................99
Prevalência residual do circulador...........................................................103
Ciao S megfelelazalábbiirányelveklényegikövetelményeinek:
- Gázirányelv2009/142/EGK
- Hatásfokirányelv92/42/EGK;
- Elektomágnesesösszeférhetőségirányelv2004/108/EGK;
- Kisfeszültségirányelv2006/95/EGK
ígyfeljogosítottaCEjelzésre
Telepítésikézikönyv-felhasználóikézikönyv............................................. 47
Műszakiadatok..........................................................................................56
Vezérlőpanel .............................................................................................91
A készülék funkcionális részei ................................................................... 93
Vízkeringetés .............................................................................................95
Elektromos rajzok ...................................................................................... 99
Keringetőszivattyúmaradékemelőmagassága ...................................... 103
Ciao S esteconformăcucerinţeleesenţialealeurmătoarelorDirective:
- Directiva gaze 2009/142/CEE;
- Directiva randament 92/42/CEE;
- DirectivadeCompatibilitateElectromagnetică2004/108/CEE;
- Directivajoasătensiune2006/95/CEE
şicaurmarebeneciazădemarcaCE
Manualdeinstalareşiutilizare .................................................................. 58
Date tehnice ..............................................................................................62
F Panoul de comenzi .................................................................................91
Elementelefuncţionalealeaparatului........................................................93
Circuitul hidraulic ....................................................................................... 95
Schemele electrice .................................................................................... 99
Prevalenţarezidualăacirculatorului........................................................103
Ciao S entspricht den grundlegenden Anforderungen der folgenden Richtlinien:
- Gas-Richtlinie 2009/142/EWG;
- Wirkungsgrad-Richtlinie 92/42/EWG;
- Elektromagnetischen Verträglichkeit 2004/108/EWG;
- Niederspannungsrichtlinie 2006/95/EWG
Deshalb trägt es die CE-Kennzeichnung.
Installateurshandbuch - Anwenderhandbuch ............................................ 69
Technische Daten ...................................................................................... 78
Bedienfeld..................................................................................................91
Kesselbestandteile ....................................................................................93
Wasserkreis ............................................................................................... 95
Schaltpläne ................................................................................................99
RestförderhöhederUmwälzvorrichtung .................................................. 103
Ciao S je skladen z bistvenimi zahtevami naslednjih direktiv:
- Plinska direktiva 2009/142/EGS,
- Direktiva o izkoristkih 92/42/EGS,
- Direktivaoelektromagnetnizdružljivosti2004/108/EGS;
- Direktiva o nizki napetosti 2006/95/EGS
zato ima pravico do oznake CE
Priročnikzamontažo-Priročnikzauporabo ............................................. 80
Tehničnipodatki ......................................................................................... 89
Krmilnaplošča ........................................................................................... 91
Sestavni deli naprave ................................................................................ 93
Hidravličnisistem.......................................................................................95
Električnesheme ....................................................................................... 99
Preostalačrpalnavišinačrpalke ..............................................................103
58
ROMANA
Înunelepărțialemanualuluisuntutilizatesimbolurile:
ATENŢIE=pentruintervenţiilecarenecesităoatenţiedeosebităşi
opregătirespecică
INTERZIS=pentruintervenţiilecareNUTREBUIEsăeexecutate
niciodată
ÎN ATENȚIA INSTALATORULUI
1 - MĂSURI FUNDAMENTALE DE SIGURANȚĂ
Centralelefabricateînunităţilenoastredeproducţiepunac-
centulpeecarecomponentă,pentruagarantasiguranţa
atâtautilizatoruluicâtşiainstalatorului,evitându-seastfel
eventualeleaccidente.Serecomandă aşadar persoanelor
calicatecadupăecareintervenţieasupraprodusului să
acordeoatenţiedeosebităconexiunilorelectrice,maialesîn
ceeacepriveşteparteaneizolatăarelorconductoare,care
nutrebuieniciodatăsăiasădinbornadeconexiuni,evitând
contactulcupărţilesubtensiunealeconductorului.
Prezentulmanualdeinstrucţiuni împreună cu manualul
utilizatorului,alcătuiescoparteintegrantăaacestuiaparat:
asiguraţi-văcăeleînsoţesc întotdeauna aparatul, chiar în
cazul în care acesta este cedat unui alt proprietar sau utilizator
sauestemontatpealteinstalaţie.Încazdedeterioraresau
pierderevărugămsăsolicitațiocopieCentruluideService
Autorizatdinzonaîncarevăaați.
Instalareacentraleişioricealtăintervenţiedeasistenţăsaude
întreţineretrebuieefectuatedepersonalulautorizatconform
indicaţiilorprevăzutedenormelenaţionaleşilocaleînvigoare.
Serecomandăaşadarinstalatoruluisăinformezeutilizatorul
cuprivirelafuncţionareaaparatuluişilamăsurifundamentale
înmateriedesiguranţă.
Centraladefaţăpoatefolositănumaiînscopulpentrucare
afostcreată.Producătorulnuîșiasumănicioresponsabilitate
contractualăsaunon-contractualăpentrudeteriorareabunuri-
lorsauvătămareaanimalelorsaupersoanelorcaurmarea
erorilordeinstalare,reglare,întreţineresauutilizareimproprie.
După dezambalare,vericaţidacăaparatuleste în stare
bunăşiaretoatecomponentele.Încazcontrar,adresaţi-vă
vânzătoruluidelacareațiachiziționataparatul.
Evacuareasupapeidesiguranţătrebuiesăeconectatăla
unsistemdecolectareşigolire.Producătoruldeclinăorice
răspunderepentrudaunele cauzate de intervenţiasupapei
desiguranţă.
Înlăturațiambalajeleîndispozitivelemenajereadecvatesau
ducându-le direct la centrele de colectare speciale.
Deşeuriletrebuieeliminateastfelîncâtsăevitațioricepericol
pentrusănătateaomuluişifărăautilizaprocedeesaumetode
care pot polua mediul.
Întimpulinstalării,informațiutilizatorulcuprivirelaurmătoarele
aspecte:
- încazdescurgereaapei,trebuiesăînchidărobinetuldealimen-
tareşisăapelezeimediatCentruldeServiceAutorizat.
- presiuneadefuncţionareainstalaţieihidraulicetrebuiesăeîntre
1şi2barşiînoricecaznutrebuiesădepăşească3bar.Încaz
denecesitate,trebuiesăcontactezepersonalulspecializatdela
Centrul de Service Autorizat.
- încazdeneutilizareacentraleipeoperioadălungădetimp,se
recomandăintervenţiaCentruluideServiceAutorizat pentru a
efectuacelpuţinurmătoareleoperații:
• poziţionareaîntrerupătoruluiprincipalalaparatuluişiacelui
generalpe“oprit”
• închiderearobinetelordecombustibilşiapă,atâtpecircuitul
deîncălzirecâtşipeceldeapăcaldămenajeră
• golireainstalaţieitermiceşimenajeredacăexistărisculdeîngheţ.
- întreţinereacentraleisevafaceminimodatăpean,programând
dintimpintervenţialaCentruluideServiceAutorizat.
2 - DESCRIEREA CENTRALEI
Ciao S C.S.I. esteocentralămuralădetipCpentruîncălzireși
producțiedeapăcaldămenajeră:înfuncțiedeaccesoriuldeevac-
uarefumutilizateaesteclasicatăîncategoriileB22P,B52P,C12,
C22,C32, C42,C52,C62, C82,C92,C12x, C32x,C42x,C52x,
C62x,C82x,C92x.
Ciao S R.S.I. este o centrală murală de tipC, cucapacităţi de
funcţionareîncondiţiidiferite:
MODUL A
doarîncălzirefărăniciunboilerexternconectat.
Centralanufurnizeazăapăcaldămenajeră.
MODUL B
doarîncălzire,curacordarelaunboilerexterncomandatdeunter-
mostat:înacestecondiții,laecarecereredecăldurădelatermo-
statulboileruluicentralafurnizează apă caldă pentru prepararea
apei calde menajere.
MODUL C
doar încălzire, cu racordare la un boiler extern (kit accesoriu
disponibilla cerere),gestionatdeo sondădetemperatură, pen-
trupreparareaapeicaldemenajere.Dacăvețiconectaunboiler
carenuestefurnizatdecătrenoi,asigurați-văcăsondaNTCare
următoarelecaracteristici:10kOhmla25°C,B3435±1%
ÎncongurațiaB23PșiB53P(cândesteinstalatălainterior),cen-
tralanupoatemontatăîndormitoare,băi,camerededușsauîn
încăperiundeseaășemineedeschisefărăunsistemadecvatde
circulațieaaerului.Încăpereaîncarevainstalatăcentralatrebuie
săaibăunsistemdeaerisireadecvat.
ÎncongurațiaC,centralapoateinstalatăînoricetipdeîncăpere,
fărăsăseimpunărestricțiicuprivirelaaerisiresaudimensiunile
încăperii.
3 - NORME DE INSTALARE
3.1 - Norme de instalare
Instalareatrebuieefectuatădepersonalautorizat:
Respectațiîntotdeaunanormeleînvigoarepeplanlocalşnaţional.
AMPLASARE
Ciao S poateinstalatălainterior(g.2).
Centralaestedotatăcuprotecţiicareasigurăfuncţionareacorectăa
întregiiinstalaţii,laoplajădetemperaturidela0°Cla60°C.
Pentrusiguranță,luațiîntotdeaunaînconsiderareurmătoarele:
Esteinterzisăutilizareacentraleide către copii sau persoane
handicapate, nesupravegheate.
Esteinterzisăacţionareadispozitivelorsauaaparatelorelec-
tricecaîntrerupătoare,electrocasnice, etc, dacă se simte
mirosul de combustibil sau de ardere. În caz de pierderi de gaz,
aerisiţiîncăpereadeschizândlarguşileşiferestrele,închideţi
robinetuldegazşiapelaţifărăîntârzierepersonalulautorizat
de la Centrul de Service Autorizat
Nuatingeţicentralacupicioarelegoalesaudacăavețipărţi
ale corpului umede sau ude
Înaintedeatrecelacurăţareaaparatului,decuplaţicentrala
delareţeauade alimentare cu curentelectric,poziţionând
întrerupătorulbipolaralinstalaţieişiîntrerupătorulprincipalal
panoului de comenzi pe OFF
Modicareadispozitivelordesiguranţăsaudereglare,fără
autorizaţiasauindicaţiileproducătoruluiestestrictinterzisă
Nutrageţi,desprindeţisaurăsucițicablurileelectricecareies
dincentralăchiardacăaceastaestedecuplatădelareţeaua
de alimentare cu curent electric
Nuacoperiţişinureduceţiînniciunfeloriciiledeaerisiredin
încăpereaundeseinstaleazăcentrala
NUlăsaţirecipientecusubstanţeinamabileînîncăperea
undeseinstaleazăcentrala
Nulăsaţiambalajelelaîndemânacopiilor.
RO
CIAO S C.S.I. - CIAO S R.S.I.
59
Pentruabeneciadeprotecţiileamintite,aparatultrebuiesăîntrunească
toatecondițiilecasăpoatăporni,deoareceoriceblocare(deex.lipsă
gaz,panădecurentelectric,intervenţiaunuidispozitivdesiguranţă)
dezactiveazăacesteprotecţii.
DISTANŢE MINIME
Pentru a permite accesul la interiorul centralei cu scopul de a executa
operaţiiledeîntreţinerecurente,estenecesarsărespectațispaţiile
minimeprevăzutepentruinstalare(g.3).
Pentruoamplasarecorectăaaparatuluireținețiurmătoarele:
-aparatulnupoateamplasatdeasupraunuiaragazsauaoricărui
altaparatdegătit.
-esteinterzisă depozitarea substanţelorinamabile în aceeași
încăperecucentrala
-părţilesensibilelacăldură(delemn,deexemplu)dinapropierea
centraleitrebuiesăeprotejatecuunstratdeizolareadecvat.
IMPORTANT
Înaintedeinstalare,serecomandăspălareaminuţioasăatuturor
conductelorinstalaţieipentruaeliminareziduurilecepotafectabuna
funcţionareaaparatului.
Amplasaţisubsupapadesiguranţăunrezervordecolectareaapei
cuevacuareadecvată,undesăseelimineapaîncazdescurgeri
cauzatedesuprapresiuneainstalaţieideîncălzire.Circuituldeapă
caldămenajerănunecesităniciunrobinetdesiguranţă,dareste
necesarsăvericaţipresiuneadinreţeasănudepăşească6bar.
Încazdeincertitudine,instalaţiunreductordepresiune.
Înaintedealimentareacentralei, vericaţi ca aceastasăe
compatibilăcugazulfurnizatdelareţea;acestlucruestemenţionat
peetichetadepeambalajşipeceaadezivă,specialăpentrutipul
degazindicatpentruaceastăcentrală.Esteextremdeimportant
săştiţicăînanumitecazuricoşuriledefumacumuleazăpresiune.
INSTALAȚIA ANTI-ÎNGHEȚ
Centralaestedotatăcuun sistem anti-îngheţ automat, care se
activeazăatuncicândtemperaturaapeiîncircuitulprimarscadesub
valoareade6°C.Acestsistemesteîntotdeaunaactivşigarantează
protecţiacentraleipânălaotemperaturăexternăde-3°C.Pentrua
beneciadeaceastăprotecţie,bazatăpefuncţionareaarzătorului,
centralatrebuiesăseaeîncondiţiidepornire;rezultăcăorice
staredeblocare(deex.absenţăgassaualimentareelectricăsau
ointervenţieaunuidispozitivdesiguranţă)dezactiveazăprotecţia.
Protecţiaanti-îngheţesteactivă chiar şi cu centrala în modde
aşteptare.Încondiţiinormaledefuncţionare,centralaarecapacitate
deautoprotecţieîmpotrivaîngheţului.Încazulîncareaparatulnu
este alimentat pe perioade îndelungate de timp, în zonele în care
seatingvaloridetemperaturămaimicide0°Cşinusedoreşte
golireainstalaţieideîncălzire,vărecomandămsăintroducețiîn
circuitulprincipalunlichidantigeldedecalitate.Urmaţicustricteţe
instrucţiunileproducătoruluiînceeacepriveştecantitateadelichid
antigelnecesarăpentrutemperaturaminimăcaresedoreştea
menţinutăîncircuitulaparatului,durataşieliminarealichidului.În
ceeacepriveştecircuituldeapăcaldămenajeră,serecomandă
golireacircuitului.Materialeledincaresuntrealizatepărţilecompo-
nentealecentralelorrezistălalichideantigelpebazădeetilenglicol.
3.2 Fixarea centralei pe perete și conexiunile hidraulice
Pentruaxacentralapeperete,utilizațișablonuldepremontare
(g.4-5)dinambalaj.Pozițiașidimensiunileconexiunilorhidraulice
sunturmătoarele:
A Returîncălzire 3/4”
B Turîncălzire 3/4”
C Conexiunegaz 3/4”
D IeșireACM 1/2”(pentruC.S.I.)-3/4”(pentruR.S.I.)
E IntrareACM 1/2”(pentruC.S.I.)-3/4”(pentruR.S.I.)
În cazul înlocuirii unei centrale Beretta model anterior, este disponibil
un kit de adaptare conexiuni hidraulice.
3.3 Conexiuni electrice
Laieşireadinfabricăcentralelesuntcablatecompletşidotatecu
cabluldealimentareelectrică;elenecesitănumaiconexiuneala
termostatuldeambient(TA)caresevaefectualaconectoriispeciali.
Pentru a avea acces la borna de conexiuni:
-poziţionaţiîntrerupătorulgeneralalinstalaţieipe“oprit”
-deşurubaţişuruburile(A)dexareamantalei(g.6)
-deplasaţiînfaţăşiapoiînsusbazacarcaseipentruaodesprinde
de pe cadru
-deşurubaţişurubul(B)panouluidecomandă(g.7)
-rotiţipanoulspredvs
-scoateţicapaculborneideconexiuni(g.8)
-introduceţicabluleventualuluitermostatdeambient(g.9)
Termostatuldeambienttrebuieconectataşacumaparepeschema
electrică.
Intrare termostat de ambient de joasă tensiune (24 Vdc).
Conectarealareţeauaelectricătrebuiesăeefectuatăprintr-un
dispozitivomnipolarcaresăasigureseparareacontactelorlaminim
3,5mm(EN60335-1,categoriaIII).Aparatulfuncţioneazăcucurent
alternativde230Volt/50Hzșioputereelectricăde115Wpentru
Ciao24C.S.I.-24R.S.I.(șiesteînconformitatecustandardulEN
60335-1).
Este obligatorie totodată conectarealauncircuitde
împământareecient,conformnormelor în vigoare pe plan
naţionalşilocal.
Serecomandădeasemenearespectareaconectăriifază-nul
(L-N).
Cabluldeîmpământaretrebuiesăecuminim2cmmailung
decât celelalte.
Utilizarea conductelor de gaz sau apă pentru împământarea
aparatelor electrice este strict interzisă.
Producătorulnurăspundede daunele provocate ca urmare a
neîmpământăriiinstalaţiei.
Pentruconectareaelectricăutilizaţicabluldealimentaredindotare.
Dacădoriţisăînlocuiţicabluldealimentare,folosiţiuncabludetip
HAR H05V2V2-F, 3 x 0,75 mm2, cu diametrul maxim exterior de
7 mm.
3.4 Racordarea la gaz
Înaintede atrecela conectareaaparatuluila reţeauade
distribuţieagazelor,vericaţică:
-suntrespectatenormelenaţionaleşilocaleînceeacepriveşte
instalarea
-tipuldegazdelareţeaestecompatibilcucelpentrucarea
fost fabricat aparatul
- conductele sunt curate.
Ţeviledegazpentruracordareaaparatuluitrebuiesăeînexte-
rior.Dacăvanecesarătrecereauneiţeviprinperete,aceasta
vatrebuisătreacăpringauracentralăcareseaăînparteade
josaşablonuluidepremontare.
Serecomandăinstalareapecircuituldegazaunuiltrucudimen-
siuneadecvată,dacăgazeledelareţeaconţinparticulesolide.
Dupăinstalare,vericaţicaîmbinărilesăeetanşe,conform
dispoziţiilornormelorreferitoarelainstalare.
3.5 Evacuarea fumului şi absorbția aerului pentru ardere
Pentruevacuareaproduselordeardere,consultaţinormelelocale
şinaţionaleînvigoare.Deasemenea, respectaţi normele locale
stabilitedePompieri,deDirecţiadedistribuţieaGazelor,şieventual
dispoziţiileprimăriei.Evacuareagazelordeardereesteasigurată
deunventilatorcentrifugalamplasatîncameradeardere,acărui
funcţionarecorectăestecontrolatăprinintermediulunuipresostat.
Centralaestefurnizațăfărăki-tulpentruevacuareafumuluişipen-
truabsorbțiaaerului,deoareceexistănumeroaseaccesoriipentru
aparatelecucamerăetanşăşitirajforţat,carepotaleseînfuncţie
decaracteristicileşi tipulinstalaţiei.Pentruevacuarea fumului şi
alimentareacuaerproaspătacentraleiesteindispensabilăfolosirea
conductelorcerticateşiconectareacorectăaacestora,conform
instrucţiunilorconţinuteînkit-uldeaccesoriifumpentrucares-a
optat.Laacelaşicoşdefumsepotconectamaimulteaparate,cu
condiţiacaacesteasăetoatecutirajforțat.
INSTALAŢIE “FORŢAT DESCHISĂ” (TIP B22P-B52P) (g, 10a)
Tubuldeevacuareafumuluipoateorientatîndirecţiaceamai
potrivităexigenţelorinstalaţiei.
Pentruinstalare,urmaţiinstrucţiunilefurnizateîmpreunăcukitul.
Înaceastăconguraţie,centralaesteconectatălatubulde
evacuareafumuluicudiametruø80mmprintr-unadaptorcu
diametruø60-80mm.
Înaceastăconguraţie,aerulpentruardereestepreluatdin
încăpereaîncareesteinstalatăcentrala,caretrebuiesăe
oîncăpereadecvatădinpunctdevederetehnicșiprevăzută
cu aerisire.
Tuburiledeevacuareafumului,dacănusuntetanșe,consti-
tuiepotenţialesursedepericol.
60
ROMANA
Tuburi de evacuare coaxiale (ø 80/125)
Centralaestefurnizatăastfelîncâtsăpoatăcuplatălaconductele
deevacuare/absorbțiecoaxiale,cuoriciuldeabsorbțieaaerului
închis.Conducteledeevacuare coaxiale pot  orientate înmai
multedirecţii,înfuncţiedeîncăpereaîncareeamplasatăcentrala,
cucondiţiacalungimilemaximedintabelsăerespectate.Pentru
instalare,urmaţiinstrucţiunilefurnizateîmpreunăcukit-ul.Pentrutra-
versareapereţilor,faceţiogaurăcuØ140mm.Înfuncţiedelungimea
conductelor,estenecesarsăintroduceţioanşă,alegând-odintre
celedindotareacentralei(vezitabelul).Oatenţiedeosebitătrebuie
acordatătemperaturiiexterioareşilungimiiconductei.Analizaţi
graceleanexatepentruavedeadacăsunteţisaunuobligaţisă
folosiţiuncolectordecondens.Încazdefuncţionarelatemperaturi
maimicide60°C,folosireaacestuicolectoresteobligatorie.Dacă
montaţiuncolectordecondens,asiguraţi-văcăaţicreatoînclinare
a conductei de evacuare a gazelor de ardere de 1% spre colector.
Conectaţisifonulcolectoruluilaevacuareaapeideconsum.Con-
ducteledeevacuareneizolateconstituiesursepotenţialedepericol.
20 C.S.I.
20 C.S.I.
Lungime tub
ø 60-100 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
pânăla0,85
Ø 39
1 1,5
dela0,85la2,35
Ø41(**)
de la 2,35 la 4,25
Ø 43
(**)instalatăîncentrală
(**)instalatăîncentrală
24 C.S.I. - 24 R.S.I.
Lungime tub
ø 60-100 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
pânăla0,85
Ø 42
1 1,5
dela0,85la2,35
Ø44(**)
de la 2,35 la 4,25 neinstalata
Lungime tub
Ø 80 125 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
de la 0,96 la3,85
Ø 39
1,35 2,2
de la3,85la7,85
Ø41(**)
de la7,85la 12,40
Ø 43
(**)instalatăîncentrală
24 C.S.I. - 24 R.S.I.
Lungime tub
Ø 80 125 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
de la 0,96 la3,85
Ø 42
1,35 2,2
de la3,85la7,85 Ø 44 (**)
de la7,85la 12,4 neinstalata
TEMPERATURĂ EXTERNĂ (°C)
COLECTOR CONDENS
FACULTATIV
COLECTOR CONDENS
OBLIGATORIU
LUNGIME TUB (m)
LUNGIME MAXIMĂ CONDUCTE COAXIALE Ø 80/125
Dacă trebuie instalați centrala Ciao S pe o instalație deja
existentă (înlocuire gamă Ciao N/Mynute), există un kit “cot
coaxial redus” care permite poziționarea centralei păstrând
aceeași gaură pentru evacuarea fumului.
Lungime tub cu cot
redus [m]
pânăla1.85
de la1.85la 4.25
Ø 41
Ø 43
45°
1
90°
1.5
Pierderi de sarcină la
ecare cot (m)
separator
aer/fum
Pentruadirecționa evacuarea în
direcțiaceamai potrivită instalației
(intrareaeradecvată)estedisponibil
un kit separator aer/fum.

86,5
kit cot coaxial redus
Flanșă fum (F)
Ciao S
20 C.S.I.
Ø 44
neinstalata
Ciao S
24 C.S.I.
Diafragma de fum (F) trebuie înlăturată, în caz de necesitate,
făcândpârghiecuoșurubelniţă.Tabelulindicălungimilerectilinii
admise.Înfuncţiedelungimeatuburilorutilizate,poatenecesar
săintroduceţiodiafragmă,alegânddinceledindotareacentralei.
Lungime tub
ø 80 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
pânăla2
Ø 42
1,2 1,7
dela2la8
Ø44(**)
dela8la 25 neinstalata
24 C.S.I. - 24 R.S.I.
(**)instalatăîncentrală
(**)instalatăîncentrală
Lungime tub
ø 80 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
pânăla1,5
Ø 39
1,2 1,7
de la 1,5 la 5
Ø41(**)
de la 5 la 14
Ø 43
20 C.S.I.
(**)instalatăîncentrală
Tuburi de evacuare coaxiale (ø 60-100)
Centralaestefurnizatăastfelîncâtsăpoatăcuplatălaconductele
deevacuare/absorbțiecoaxiale,cuoriciuldeabsorbțieaaerului
(E)închis(g.10b).Conducteledeevacuarecoaxialepotorientate
înmaimultedirecţii,înfuncţiedeîncăpereaîncareeamplasată
centrala,cucondiţiacalungimilemaximedintabelsăerespectate.
Pentruinstalare,urmaţiinstrucţiunilefurnizateîmpreunăcukit-ul.
Înfuncţiedelungimeaconductelor, este necesar săintroduceţi
oanșăalegând-odintreceledindotareacentralei(a sevedea
tabeleledemaijos).Atuncicândestenecesar,anșadefum(F),
poatescoasăfăcândpârghiecuoşurubelniţă.Tabeluldemaijos
redălungimileliniarepermise.Înfuncţiedelungimeaconductelor
utilizate,estenecesarsăintroduceţioanșăalegând-odintrecele
dindotareacentralei(vezitabeluldemaijos).
CIAO S C.S.I. - CIAO S R.S.I.
61
B22P/B52PAbsorbțieaerlainteriorșievacuarelaexterior
C12-C12x Evacuare pe perete, concentrică. Tuburile pot pleca din
centralăînmodindependent,darieşiriletrebuiesăeconcentricesau
sucientdeapropiatepentruaexpuselaaceleașicondițiidevânt(dist
max50cm)
C22Evacuareconcentricăîncoşdefumcomun(absorbțieşievacuare
înacelaşicoş)
C32-C32x Evacuareconcentrică,prinacoperiș.IeşiricaîncazulC13
C42-C42xEvacuareşiabsorbțieaerîncoşuridefumcomunesausepa-
rate,darexpuselavântînaceeaşimăsură
C52-C52xEvacuareşiabsorbțieseparate,prinperetesauacoperiş,dar
înzonesupuseunorpresiunidiferite.Evacuareaşiabsorbțianutrebuie
săeniciodatăpoziţionatepepereţiopuşi
C62-C62x Evacuare şi absorbție realizate cu conducte din comerţ,
certicateseparat(1856/1)
C82-C82xEvacuareîntr-unsingurcoşdefum(independentsaucomun)
cuabsorbțieprinperete
C92-C92xEvacuareprinacoperiș(similarC32)șiabsorbțieaerdela
uncoșdefumunic









 






Rear outlet
Lungime tub
ø 80 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
2+2
Ø 42
1,2 1,7
>2+2 ÷ 6+6 Ø 44 (**)
>6+6 ÷ 16+16 neinstalata
20 C.S.I.
Lungime tub
ø 80 [m]
Flanșă fum (F)
Pierderi de sarcină la
ecare cot (m)
45° 90°
1+1
Ø 39
1,2 1,7
> 1+1 ÷ 4+4 Ø41(**)
> 4+4 ÷ 10+10 Ø 43
24 C.S.I. - 24 R.S.I.
(**)instalatăîncentrală
(**)instalatăîncentrală
TUBURI DE EVACUARE SEPARATE (ø 80) (g. 11)
Tuburileseparatepotorientateînmaimultedirecţii,înfuncţiede
cerințeleîncăperii.
ToPentruautilizatubuldeabsorbțieaertrebuiesăselectațiuna
dintreceledouăintrări(GșiH).Scoatețicapaculdeînchiderexat
cușuruburișiutilizațiadaptorulspecicintrăriiselectate.
Adaptorulpentruintrareaaeruluiø80(X)trebuiesăeorien-
tatcorect;astfel,estenecesarăxareasacuşuruburi,pentru
caaripadepoziţionaresănuloveascăcarcasa:Xadaptor
intrareaerø80-Yadaptorintrareaerdelaø60laø80.
Atuncicândestenecesar,anșadefum(F),poatescoasăfăcând
pârghiecuoşurubelniţă.
Tabelul de mai jos redă lungimile liniare permise. În funcţie de
lungimeaconductelorutilizate,estenecesarsăintroduceţioanșă
alegând-odintreceledindotareacentralei(vezitabeluldemaijos).
3.6 Umplerea instalației de încălzire (g. 13)
Dupăefectuareaconexiunilorhidraulice,sepoatetrecelaumplerea
instalaţiei de încălzire. Operaţia trebuie efectuată cu instalaţia
rece,executândoperaţiile:
-deschideţicapaculvaneideevacuareaerautomatăefectuând
2-3rotaţii(I)
-vericaţidacărobinetuldealimentarecuapăreceestedeschis
-deschideţirobinetuldeumplere(Lg.13pentruC.S.I.–extern
pentruR.S.I.)pânăcândpresiuneaindicatădemanometrueste
cuprinsăîntre1şi1,5bar.
Dupăumplere,închideţirobinetul.
Centralaestedotatăcuunseparatordeaeraşadarnuestenece-
sarsăinterveniţimanual.
Arzătorulseaprindenumaidacăfazadeevacuareaaeruluieste
terminată.
3.7 Golirea instalaţiei de încălzire
Pentruagoliinstalaţiaprocedaţiastfel:
-opriţicentrala
-deschideţirobinetuldegolireacentralei(M)
-goliţipunctelecelemaijoasealeinstalației.
3.8 Golirea instalației ACM (doar pentru modelul C.S.I.)
Atuncicândexistărisculdeîngheț,circuituldeapăcaldămenajeră
trebuiegolitdupăcumurmează:
-închidețirobinetulprincipalalrețeleideapă
-deschidețitoțirobinețiideapăcaldășirece
-goliţipunctelecelemaijoasealeinstalației.
ATENȚIE
Evacuareasupapeidesiguranţă(N)trebuiesăeconectatălaun
sistemadecvatdecolectareşigolire.Producătorulaparatuluinu
răspundededaunelecauzatedeintervenţiasupapeidesiguranţă.
62
ROMANA
4 PUNERE ÎN FUNCȚIUNE ȘI FUNCȚIONARE
4.1 Vericări preliminarii
Primapunereînfuncţiunetrebuie să e efectuată de persoane
competente, trimise de Centrul de Service Autorizat Beretta.
Înaintedeapornicentrala,vericaţica:
a)caracteristicile reţelelor de alimentare (energie electrică, apă,
gaz)săcorespundădatelordepeplăcuțatehnică
b)tuburilecareiesdincentralăsăeacoperitecuunstratdeizolație
termică
c) conducteledeevacuareagazelordeardereşiabsorbțieaersă
eeciente
d)săegarantatetoatecondiţiilepentruaexecutaoperaţiilede
întreţinerecurentăîncazulîncarecentralaestemontatăîntre
piesedemobiliersaupereţiapropiaţi
e)circuituldealimentarecugazaaparatuluisăeetanş
f)debituldecombustibilsăcorespundăvalorilornecesareînfuncţie
de tipul centralei
g)instalaţiadealimentareaaparatuluicucombustibilsăcorespundă
cadimensiunişicaracteristicicudebitulpecaretrebuiesăîlasig-
ureşisăedotatăcutoatedispozitiveledesiguranţăşicontrol,
conform normelor în vigoare.
4.2 Punerea în funcțiune a centralei
Pentrupornireacentraleiestenecesarsă:
-alimentaţielectriccentrala
-deschideţirobinetuldegazalinstalaţiei,pentruapermitealimen-
tarea cu combustibil a aparatului
-rotiţiselectoruldefuncţie(1-g.1a)înpoziţiadorită:
Ciao S C.S.I.:
Modul vară:rotindselectorul pesimbolulvară (g. 2a)se
activează funcţia tradiţională doar apă caldă menajeră. În ca-
zuluneicererideapăcaldă menajeră,display-uldigitalindică
temperaturaapeicaldemenajereşisuntvizualizatesimbolulde
alimentarecuapăcaldăşisimbolulacără
Modul iarnă: rotind selectorul de funcţii în cadrul yonei mar-
catecu*şi-(g.2b),centralafurnizeazăîncălzireșiapăcaldă
menajeră.Încazuluneicereridecăldură,centralaporneșteși
display-uldigitalindicătemperaturaapeideîncălzireşisuntvi-
zualizatesimboluldeîncălzireşisimbolulacără(g.3a).Înca-
zuluneicererideapăcaldă menajeră,display-uldigitalindică
temperaturaapeicaldemenajereşisuntvizualizatesimbolulde
alimentarecuapăcaldăşisimbolulacără(g.4a)
Preîncălzire(apă caldă mairapid): rotiți butonul de reglarea
tempe-raturiiapeicaldemenajere (2 - g. 1a)pesimbolul
(g.5a),pentruaactivafuncțiadepreîncălzire.Aceastăfuncție
menținecaldăapadinschimbătoruldecăldurăsanitar,pentrua
reducetimpuldeașteptarepânălavenireaapeicalde.Display-
ul așează temperatura de tura apei de încălzire saua apei
caldemenajere,înfuncțiedecererea în curs. În timpul aprin-
deriiarzătorului,caurmareauneicereridepreîncălzire,pedis-
playesteașatsimbolul (g.5b).Pentruadezactivafuncția
depreîncălzire,rotițidinnoubutonuldereglareatemperaturii
apei calde menajere pe simbolul .Aducețibutonuldereglare
atemperaturiiapeicaldemenajereînpozițiadorită.Funcțianu
esteactivăcucentralaînpozițiaOFF:selectoruldefuncție(1
g.1a)on OFF.
Ciao S R.S.I.:
Modul vară (activ numai cu boilerul extern racordat): rotind
selectorul pe simbolul vară (g. 2a) se activează funcţia
tradiţionalădoarapăcaldămenajerășicentralafurnizeazăapă
latemperaturasetatăpeboiler.Încazuluneicererideapăcaldă
menajeră,display-uldigitalindicătemperaturaapeicaldemena-
jereşisunt vizualizate simboluldealimentarecu apă caldăşi
simbolulacără
Modul iarnă:rotindselectoruldefuncţiiîncadrulyoneimarcate
cu*şi-(g.2b),centralafurnizeazăapăpentruîncălzireși,dacă
esteconectatălaunboilerextern,apăcaldămenajeră.Înca-
zuluneicereridecăldură,centralaporneșteșidisplay-uldigital
indicătemperaturaapeideîncălzireşisuntvizualizatesimbolul
deîncălzireşisimbolulacără(g.3a).Încazuluneicereride
apă caldă menajeră, display-ul digital indicătemperatura apei
caldemenajereşisuntvizualizatesimboluldealimentarecuapă
caldăşisimbolulacără(g.4a).
Reglațitermostatuldeambientlatemperaturadorită(~20°C)
Ciao S C.S.I.: Reglarea temperaturii apei calde menajere
Pentruareglatemperaturaapeicaldemenajere(băi,duș,bucătărie
etc.),rotițibutonulmarcatcusimbolul (g.2b)încadrulzonei
marcatecu+și-.
Centralaseaăîntr-ostaredestand-bypânăcând,înurmaunei
cereride căldură,arzătorulseaprinde șidisplay-uldigital indică
temperaturaapei calde menajere şi sunt vizualizatesimbolul de
alimentarecuapăcaldăşisimbolulacără.Centralavarămâneîn
funcțiunepânăcândvoratinsetemperaturilereglate,dupăcare
vatrecedinnouînstareade“stand-by”.
Dacăseaprindeledulroșu,înconcordanțăcusimbolul pe pan-
ouldecomandăînseamnăcăcentralaseaăîntr-ostaredeoprire
temporară (vezi capitolulsemnalizări luminoase și anomalii). Pe
display-uldigitalesteașatcodulrespectiveianomalii(g.6a).
Ciao S R.S.I.: Reglarea temperaturii apei calde menajere
CAZUL A doarîncălzire–nuseaplicăcalibrarea
CAZUL Bdoarîncălzire+boilerexterncutermostat–nuseaplică
calibrarea.
CAZUL Cdoarîncălzire+boilerexterncusondă–pentruaregla
temperaturaapeicaldedinboiler,rotițibutonulînsensulacelorde
ceasornicpentruacreștetemperaturașiînsensinverspentruao
diminua.
Centralaseaăîntr-ostaredestand-bypânăcând,înurmaunei
cereride căldură,arzătorulseaprinde șidisplay-uldigital indică
temperaturaapei calde menajere şi sunt vizualizatesimbolul de
alimentarecuapăcaldăşisimbolulacără.
Centralavarămâneînfuncțiunepânăcândvoratinsetemper-
aturilereglate,dupăcarevatrecedinnouînstareade“stand-by”.
Dacăseaprindeledulroșu,înconcordanțăcusimbolul pe pan-
ouldecomandăînseamnăcăcentralaseaăîntr-ostaredeoprire
temporară (vezi capitolulsemnalizări luminoase și anomalii). Pe
display-uldigitalesteașatcodulrespectiveianomalii(g.6a)
Ciao S C.S.I. - Ciao S R.S.I.: Funcția Sistem Automat de
Reglare a Ambientului (S.A.R.A.) g. 7a
Poziționândselectoruldetemperaturăaapeideîncălzireînsec-
torulevidențiatprinscrisulAUTO–valoridetemperaturădela55la
65°C-theS.A.R.A.seactiveazăsistemuldeautoreglareS.A.R.A.:
în baza semnalului de închidere a contactului termostatului de am-
bientcentralavariazăautomattemperaturaapeideîncălzire.După
cetemperaturacareafostafostreglatăcuajutorulselectoruluide
temperaturăapădeîncălzireesteatinsă,începeonumărătoarede
20minute.Dacăînacesttimp,termostatuldeambientcontinuăsă
cearăcăldură,valoareadetemperaturăsetatăcreștecu5°C.
Dupăceafostatinsănouavaloare,începeoaltănumărătoarede
20 minute.
Dacă în acest timp, termostatul de ambient continuă să ceară
căldură,valoareadetemperaturăsetatăcreștecu5°C.
Aceastăvaloarenouădetemperaturăreprezintăsumatemperatu-
riisetatemanualcuselectoruldetemperaturăapădeîncălzireșia
creșteriide+10°CafuncțieiS.A.R.A.
După al doilea ciclu de creștere,temperatura estemenținută la
valoarea setată +10°C până când este satisfăcută cererea de
căldurădelatermostatuldeambient.
Oprirea temporară
Încazulabsențelortemporare,poziționațiselectoruldefuncție(1-
g.1a)pe (OFF).
Înacestmod,lăsândactivealimentareaelectricășialimentareacu
combustibil,centralaesteprotejatădesistemele:
- Anti-îngheț: atuncicândtemperaturaapei din centralăscade
sub5°,pompadecirculaţieseactiveazăși,dacăestenecesar,
șiarzătorullaputereminimă,pentruareaducetemperaturaapei
lavaloridesiguranţă(35°C).Întimpulcicluluianti-îngheț,pedis-
playaparesimbolul
- Anti-blocare pompă de circulație:uncicludefuncţionarese
activeazălaecare24oredepauză.
- Anti-îngheț ACM (doar când este conectat un boiler cu
sondă):funcțiaesteactivatăatuncicândtemperaturamăsurată
desondaboileruluiscadesub5°.Atunciestegeneratăocerere
decăldurăcupornirea arzătoruluilaputereminimă,careeste
menținutăpânăcândtemperaturaapeiatingevaloareade55°C.
Întimpulcicluluianti-îngheț,pedisplayaparesimbolul .
CIAO S C.S.I. - CIAO S R.S.I.
63
Oprirea pentru perioade lungi
Încazulabsențelortemporare,poziționațiselectoruldefuncție(1-
g.1a)pe (OFF).
Închidețirobineteledegazșideapăaleinstalațiilortermiceșisanitare.
Înacestcaz,funcțiaanti-înghețestedezactivată:golițiinstalațiile
dacăexistărisculdeîngheț.
4.4 Semnalizări luminoase și anomalii
Pedisplay-uldigitalesteindicatăstareadefuncționareacentralei.
Tipuriledeașaresuntdescriseîntabeluldemaijos.
4.5 Reglaje
Centralaeste dejareglatădinfabrică decătreproducător.Dacă
totuși este necesar să efectuați din nou reglajele, de exemplu
dupăoîntrețineredeexcepție,dupăînlocuireavaneidegazsau
dupătransformareadepegazmetanpeGPL,urmațiinstrucțiunile
prezentate mai jos.
Reglarea puterii maxime trebuie efectuată obligatoriu în
ordinea indicată și exclusiv de către personalul autorizat.
-scoateţicarcasadeşurubândşuruburiledexareA(g.6)
-deşurubaţi(2rotaţii)şurubulcarefaceprizadepresiunecarese
aăînavaldevanadegazşicuplaţimanometrul
-decuplaţiprizadecompensareacamereideaer
4.5.1 Ciao S C.S.I.: REGLAREA PUTERII MAXIME ȘI A MINIMU-
LUI SANITAR
- Deschidețilamaximrobinetuldeapăcaldă
-pepanouldecomandă:
-aducețiselectoruldefuncțiepe (vară)(g.2a)
-rotițiselectoruldetemperaturăACMlamaxim(g.8a)
-pornițicentralapoziționândîntrerupătorulprincipalpe“pornit”
- vericațicapresiuneacitităpemanometrusărămânăconstantă;
sau, cu ajutorul unui miliampermetru montat în serie cu modula-
torul,vericaţidacăpemodulatorseproducevaloareamaximă
disponibilădecurent(120mApentruG20și165mApentruGPL)
-înlăturațicapaculdeprotecțieașuruburilor de reglare, făcând
pârghiecuoșurubelniță(g.15)
-CuocheietipfurcăCH10interveniţiasuprapiuliţeidereglare
aputeriimaximepânăcândobţineţivaloareaindicatăîntabelul
"Date tehnice"
-Decuplaţiunconectorfastondepemodulator
-Aşteptaţi ca presiunea de pe manometru să se stabilizeze la
valoareaminimă
-CuocheieAllenacţionaţişurubulroşudereglareaputeriimin-
ime şi calibraţi până când pe manometru puteţi citi valoarea
indicatăîntabelul"Datetehnice"
-Cuplaţidinnouconectorulfastonalmodulatorului
-închidețirobinetuldeapăcaldămenajeră
-Puneţilaloccapaculdeprotecţieaşuruburilordereglare.
Ciao S R.S.I.: Reglarea puterii maxime și minime
-Setațiselectoruldefuncțiepeiarnă (g.2b)
-scoateţicarcasaşiaccesaţiplaca
-introduceţijumperiiJP1șiJP2
-Aducețitrimmer-ulP2lavaloaremaximăutilizândoșurubelniță
(rotițiînainte)
-pornițicentralapoziționândîntrerupătorulprincipalpe“pornit”
- vericațicapresiuneacitităpemanometrusărămânăconstantă;
sau, cu ajutorul unui miliampermetru montat în serie cu modula-
torul,vericaţidacăpemodulator se produce valoarea maximă
disponibilădecurent(120mApentruG20și165mApentruGPL).
-înlăturațicapaculdeprotecțieașuruburilordereglare,făcând
pârghiecuoșurubelniță
-CuocheietipfurcăCH10interveniţiasuprapiuliţeidereglare
aputeriimaximepânăcândobţineţivaloareaindicatăîntabelul
"Date tehnice "
-Decuplaţiunconectorfastondepemodulator
- Aşteptaţi ca presiunea depe manometru să se stabilizeze la
valoareaminimă
- CuocheieAllenacţionaţişurubulroşudereglareaputeriimin-
ime şi calibraţi până când pe manometru puteţi citi valoarea
indicatăîntabelul"Datetehnice"
-Cuplaţidinnouconectorulfastonalmodulatorului
-Oprițialimentareaelectricăacentralei
-ScoatețijumperiiJP1șiJP2
-Puneţilaloccapaculdeprotecţieaşuruburilordereglare.
4.5.2 REGLAREA ELECTRICĂ A MINIMULUI ȘI MAXIMULUI DE
ÎNCĂLZIRE
Funcţiade“reglareelectrică”seactiveazăşisedezactivează
numaiprinjumperul(JP1)(g.16).
PedisplayapareADJ carearatăcăproceduradecalibrareeste
în curs.
Abilitareafuncţieipoatefăcutăastfel:
-alimentândplacacujumperulJP1montatşiselectoruldefuncţii
înpoziţia“iarnă”,independentdeeventualaprezenţăaaltorcer-
eridefuncţionare.
STARE CENTRALĂ DISPLAY
Stand-by -
Stare OFF OFF
AlarmăblocaremodulACF
A01
AlarmăanomalieelectronicăACF
A01
Alarmătermostatlimită
A02
Alarmăpresostatdeaer
A03
AlarmăpresostatH2O
A04
AnomaliesondăNTCACM(C.S.I.șiR.S.Idoar
cuboilerexterncusondă)
A06
AnomalieNTCîncălzire
A07
Flacărăparazit
A11
Reglareelectricăminimșimaximîncălzire
ADJ
Tranzitoriuînașteptareapornirii 88
°C
intermitent
Intervențiepresostatdeaer
intermitent
IntervențiepresostatH2O
intermitent
FuncțiePreîncălzireactivă(doarC.S.I.)
CereredecăldurăPreîncălzire(doarC.S.I.)
intermitent
Prezențăsondăexternă
CereredecăldurăACM 60
°C
Cererdecăldurăîncălzire 80
°C
Cererdecăldurăanti-îngheț
Flacărăprezentă
Pentru a restabili funcționarea (deblocare alarme):
Anomalii A 01-02-03
Poziționațiselectoruldefuncțiepe (OFF),așteptați5-6secund
șireaduceți-lînpozițiadorită (modul vară) sau (modul
iarnă).
Dacătentativelededeblocarenureactiveazăfuncționarea,solicitați
intervențiaCentruluideServiceAutorizat.
Anomalia A 04
Pelângăcoduldeanomalie,pedisplayesteașatșisimbolul .
Vericațivaloareapresiuniiindicatedetermomanometru:
dacă este sub 0,3 bar, poziționați selectorul de funcție pe oprit
(OFF)șiacționațirobinetuldeumplere(Lg.13pentruC.S.I.
– extern pentru R.S.I.)pânăcând presiunea ajungelao valoare
cuprinsăîntre1și1,5bar.
Ulterior,aducețiselectoruldefuncțieînpozițiadorită (vară)
sau (iarnă).
Centralavaefectuauncicludeevacuareaaeruluicuduratăde
circa 2 minute.
În cazul în care căderile de presiune sunt frecvente, solicitați
intervențiaCentruluideServiceAutorizat.
Anomalia A 06 (C.S.I.)
Centralafuncționeazănormaldarnugaranteazăstabilitateatem-
peraturiiapeicaldemenajerecarerămânesetatălaotemperatură
deaproximativ50°C.EstenecesarăintervențiaCentruluideSer-
vice Autorizat.
Anomalia A 07
SolicitațiintervențiaCentruluideServiceAutorizat.
64
ROMANA
- inserând jumperulJP1,cuselectoruldefuncţiipe“iarnă”,fără
cereredecăldurăîncurs.
Activareafuncţieiprevedeaprindereaarzătoruluiprinsimu-
lareauneicereridecăldurăîncircuituldeîncălzire.
Pentruaefectuaoperaţiiledereglareprocedaţiastfel:
-opriţicentrala
-scoateţicarcasaşiaccesaţiplacadecomandă
-introduceţijumperulJP1(g.16)pentruaabilitaselectoarelede
pepanouldecomenziînvedereareglajelordeefectuat(minşi
maxîncălzire)
-asiguraţi-văcăselectoruldefuncţiiestepe“iarnă”(veziparagr.4.2).
-alimentaţielectriccentrala
Placaelectricăsubtensiune(230Volt)
-rotiţi selectorul de reglare a temperaturii apei din circuitul de
încălzire B (g. 17) până când obţineţi valoarea minimă de
încălzire,dupăcumseindicăîntabelulmultigaz
-montaţijumperulJP2(g.16)
- rotiţiselectoruldereglareatemperaturiiapeicaldemenajereC
(g.17)pânăcândobţineţi valoareaminimădeîncălzire,după
cumseindicăîntabelulmultigaz
- demontaţijumperulJP2pentruamemorizavaloareamaximăpe
circuituldeîncălzire
-demontaţijumperulJP1pentruamemorizavaloareaminimăîn
circuituldeîncălzireşipentruaieşidinproceduradereglare
-cuplaţidinnouprizadecompensarelacameradeaer
Decuplaţimanometrulşiînşurubaţişurubulprizeidepresiune
Pentruaterminafuncţiadereglarefărăamemorizavalorile
introduse,faceţiastfel:
a)aduceţiselectoruldefuncţiipe (OFF)
b)decuplaţiaparatuldelaalimentareaelectrică
c)scoateţiJP1/JP2
Funcţiadereglareseîncheieautomat,fărăcanoiledate(valo-
riminşimax)săememorate,la15minutedelaactivareasa.
Funcţia se încheie automat şi dacă intervine o blocare
denitivăsauseopreşteaparatul.
Şiînacestecazuri,noilevaloriNUsuntmemorizate.
Notă
Pentru a executa numai reglarea valorii maxime la încălzire se
poatedemonta jumperulJP2(ceeace introduceînmemorie val
max), apoi încheia funcţia (fără a memoriza aşadar valoarea
minimă)sauaducândselectoruldefuncţiipeOFFsaudecuplând
aparatuldelareţeauaelectrică.
După orice intervenţie asupra componentei de reglare a
valveidegaz,sigilaţidinnoucomponentaculacdesigilare.
Dupăreglare:
-setațipetermostatuldeambienttemperaturadorită
-mutaţiselectoruldetemperaturăapădeîncălzireînpoziţiadorită
-închideţicapaculpanouluidecomandă
-montaţilaloccarcasa
4.6 Gas conversion operations
Conversia de la un tip de gaz la altul estesimplăşisepoateface
şi cu centrala instalată. Centrala este livrată din fabrică pentru
funcţionareacugazmetan(G20)conformcelorindicatepeplaca
cudatetehnice.Existătotuţiposibilitateadeamodicaaparatele
pentrualucraşicualtetipuridegaze,folosindseturilespeciale,
carepotlivratelacerere:
- set de transformare pentru Metan
- set de transformare pentru GPL
Pentrudemontare,respectaţiinstrucţiuniledemaijos:
- decuplaţi aparatul de la reţeaua de alimentare cu curent şi
închideţirobinetuldegaz
- scoateţiînordine:carcasa,capaculcamereideaer,capaculca-
mereideardere(g.19)
-decuplaţicablulelectrodului
-extrageţicanaluldecabluinferiordinlocaşulcamereideaer
-scoateţişuruburiledexareaarzătoruluişiscoateţi-lîmpreună
cuelectrodulşicablurilerespective
-cuocheietubularăsaubifurcată,scoateţiduzeleşidistanţierele
şiînlocuiţitotulcucomponenteledinkit.
Utilizaţişimontaţidistanţiereledinkit-ulfurnizat,chiardacă
aveaţiuncolectorfărădistanţiere.
-introduceţiarzătorulîncameradeardereşiînşurubaţişuruburile
dexarelacolectoruldegaz
-poziţionaţicanaluldecablucucablulelectroduluiînlocaşulsău,
pe camera de aer
-refacețiconexiunilecabluluielectrodului
-montaţilaloccapaculcamereideardereşicapaculcamereideaer
-rabataţipanouldecomenzisprecentrală
-deschideţicapaculplăcii
-peplacadecontrol:(g.16):
-dacă modicaţi aparatul pentru a lucra cu GPL în loc de gaz
metan,montaţijumperulînpoziţiaJP3
-dacămodicaţiaparatulpentrualucracugazmetanînlocde
GPL,scoateţijumperuldinJP3
-montaţilaloctoatecomponentelescoaseanterior
-alimentaţicutensiunecentralaşideschideţirobinetuldegaz(cucen-
tralaînfuncţiune,vericaţietanşeitateaîmbinărilorcircuituluidegaz.
Modicarea trebuie e făcută numai de persoanele
calicate profesional.
După modicarea aparatului, reglaţi-l din nou urmând
indicaţiile din paragraful referitor la reglaje; aplicaţi pe
aparat eticheta cu noile date tehnice, din kit-ul furnizat.
5 ÎNTREȚINERE
Pentruagarantacaracteristicileaparatuluid.p.d.v.alecienţeişi
funcţionalităţii,precumşipentruarespectadispoziţiilelegilorîn
vigoare,estenecesarsăexecutaţioperaţiiledeîntreţinerelainter-
vale regulate de timp.
Frecvenţadeexecuţieacontroalelordepindedecondiţiiledeinsta-
lareşideutilizareaaparatului;totuşi,serecomandăminimuncontrol
pean,deefectuatdecătrepersoanelecalicatedelaCentrelede
Service Autorizat.
Dacăintervenţiilesauoperaţiiledeîntreţineresefacpestructuri
apropiate de conductele de gaze sau de dispozitivele de evacuare
fumsaudeaccesoriilelor,oprițiaparatul.
Lanalullucrărilorcereţipersoanelorcalicatesăvericeecienţa
centraleișiaconductelordeevacuare.
IMPORTANT:înainte de a trece la curăţarea sau întreţinerea
aparatului,oprițiîntrerupătorulacestuiaprecumşipecelalinstalaţiei,
pentruadecuplaaparatuldelareţeauadecurent;deasemenea,
închideţirobinetuldegazedepecentrală.
Nucurăţaţiaparatulsaucomponentelesalecusubstanţeuşor
inamabile(deex.benzină,alcool,etc.).
Nucurăţaţipanourile,componentele vopsite sau din plastic cu
diluanţipentruvopsele.
Curăţareapanourilorsevafacenumaicuapăcusăpun.
5.1 Vericarea parametrilor de ardere
Ciao S C.S.I.:
Pentruaefectuaanalizaarderiiprocedaţiastfel:
- deschidețilamaximrobinetuldeapăcaldă
-aducețiselectoruldefuncțiepe vară și selectorul de
temperaturăACMlavaloaremaximă(g.8a).
-scoatețișurubulcapaculprizeideanlizăfum(g.18)șiintroduceți
sondele
-alimentațielectriccentrala
Ciao S R.S.I.:
-oprițicentrala
-aducețiselectoruldefuncțiepeiarnă
-scoatețicarcasașiaccesațiplacadecomandă
-IntroduceţijumperiiJP1şiJP2
-facețipârghiecuoşurubelniţăpentruascoatecapaculpanoului
decomandă(g.22)
-aduceţipotenţiometruldereglareP2lavaloareamaximă,utilizând
oşurubelniţă(rotiţiînsensulacelordeceasornic)
-îndepărtaţişurubulcapaculuiprizeideanalizăaarderii(g.18)
şiintroduceţisondele
-alimentaţielectriccentrala.
Aparatulfuncţioneazălaputereamaximăşidecisepoateefectua
controlul arderii.
Lanalulanalizei:
-închideţirobinetuldeapăcaldă
-scoateţisondaanalizatoruluişiînchideţiprizadeanalizăaarderii
xândcugrijăşurubulpecapaculacesteia.
CIAO S C.S.I. - CIAO S R.S.I.
65
UTILIZATOR
1A MĂSURI FUNDAMENTALE DE SIGURANȚĂ
Prezentul manualdeinstrucţiuniconstituieparteintegrantăaaces-
tuiaparat:asiguraţi-văcăeleînsoţescîntotdeaunaaparatul,chiar
în cazul în care acesta este cedat unui alt proprietar sau utilizator
sauestemontatpealteinstalaţie.Încazdedeterioraresaupier-
derevărugămsăsolicitațiocopieCentruluideServiceAutorizat
dinzonaîncarevăaați.
Instalareacentraleişioricealtăintervenţiedeasistenţăsau
deîntreţineretrebuieefectuatedepersonalulautorizatcon-
formindicaţiilorprevăzute de normelenaţionaleşilocaleîn
vigoare.
Pentruinstalare,contactațipersonalulautorizat.
Centralapoatefolositănumaiînscopulpentrucareafost
creată. Producătorul nu își asumă nicio responsabilitate
contractualăsaunon-contractualăpentrudeteriorareabunuri-
lorsauvătămareaanimalelorsaupersoanelorcaurmareaero-
rilordeinstalare,reglare,întreţineresauutilizareimproprie.
Modicarea dispozitivelor de siguranţăsau de reglare, fără
autorizaţiasauindicaţiileproducătoruluiestestrictinterzisă.
Acestaparatserveştelaproducereadeapăcaldă,decitre-
buiesăe conectatlao instalaţiedeîncălzireşi launade
distribuţieaapeicaldemenajere,compatibilcuprestaţiileşi
puterea sa.
Încazdescurgereaapei,închidețirobinetuldealimentareşi
săapelezeimediatCentruldeServiceAutorizat.
În caz deabsenţă prelungită, închideţi robinetulde gaze şi
stingeţiîntrerupătorulgeneralalaparatuluipentrua-ldecupla
delareţeauadealimentareelectrică.Dacăexistăpericolulde
îngheţ,goliţiapadincentrală.
Vericatidincândîncândpresiuneadefuncţionaresănuco-
boare sub1 bar.
Încazdeanomaliesaufuncţionaregreşităaaparatului,opriţi-l
şi apelaţi persoanele calicate; repararea ca şi orice altă
intervenţiepersonalăesteinterzisă.
Întreţinerea aparatului se va face minim o dată pe an: pro-
gramarea intervenţiei la Centrul de Service Autorizat evită
pierderea de timp sau de bani.
Boileruserequirestostrictlyobservesomebasicsafetyrules:
Donotusetheapplianceinanymannerotherthanitsintended
purpose.
Itisdangeroustotouchtheappliancewithwetordampbody
parts and/or in bare feet.
Under no circumstances cover the intake grids, dissipation grids
and ventilation vents in the installation room with cloths, paper
oranyothermaterial.
Donotactivateelectricalswitches,telephoneoranyotherobject
that causes sparks if there is a smell of gas. Ventilate the room
byopeningdoorsandwindowsandclosethegascentraltap.
Donotplaceanythingintheboiler.
Donotperformanycleaningoperationiftheapplianceisnot
disconnectedfromthemainpowersupply.
Do not cover or reduce ventilation opening of the room where
the generator is installed.
Do not leave containers and inflammable products in the
installation room.
Do not attempt to repair the appliance in case of failure and/or
malfunctioning.
It is dangerous to pull or twist the electric cables.
Children or unskilled persons must not use the appliance.
Do not intervene on sealed elements.
Pentruautilizaîncelmaibunmodaparatul,amintiţi-văcă:
- spălarea în exterior aaparatului cu apă şi săpunameliorează
aspectul estetic şi împiedică ruginirea panourilor, prelungind
aşadarduratadeviaţăaaparatului;
-încazulîncarecentralamuralăsemonteazăîntrepiesedemo-
biliersuspendate,estenecesarsălăsaţiminim5cmpeecare
partepentruapermiteaerisireaaparatuluişiîntreţinerea;
- instalarea unui termostat de ambient va asigura un confort optim,
vapermiteutilizarearaţionalăa căldurii şi va economisi ener-
gia;centralapoatecuplatălaunprogramatorcarevacoman-
da aprinderea şi stingerea centraleila anumite ore din zisau
săptămână.
2A PORNIREA CENTRALEI
Prima punere în funcţiune trebuie să e efectuată de persoane
competente, trimise de Centrul de Service Autorizat Beretta. Ulte-
rior,dacăvanevoiesărepuneţiînfuncţiunecentrala,procedaţi
astfel.
Pentrupornireacentraleiestenecesarsă:
-alimentaţielectriccentrala
-deschideţirobinetuldegazalinstalaţiei,pentruapermitealimen-
tarea cu combustibil a aparatului
-rotiţiselectoruldefuncţie(1-g.1a)înpoziţiadorită:
Ciao S C.S.I.:
Modul vară: rotind selectorul pe simbolul vară (g. 2a) se
activează funcţia tradiţională doar apă caldămenajeră. Încazul
unei cereri de apă caldămenajeră, display-uldigitalindicătem-
peraturaapeicaldemenajere şi sunt vizualizatesimboluldeali-
mentarecuapăcaldăşisimbolulacără
Modul iarnă:rotindselectoruldefuncţiiîncadrulyoneimarcatecu
*şi-(g.2b),centralafurnizeazăîncălzireșiapăcaldămenajeră.
Încazuluneicereridecăldură,centralaporneșteșidisplay-uldigi-
talindicătemperaturaapeideîncălzireşisuntvizualizatesimbolul
deîncălzireşisimbolulacără(g.3a).Încazuluneicererideapă
caldă menajeră, display-ul digital indică temperatura apei calde
menajereşisuntvizualizatesimboluldealimentarecuapăcaldăşi
simbolulacără(g.4a)
Preîncălzire (apăcaldămairapid):rotițibutonuldereglareatem-
pe-raturiiapeicaldemenajere(2-g.1a)pesimbolul (g.5a),
pentru a activa funcția de preîncălzire.Această funcție menține
caldăapadinschimbătoruldecăldurăsanitar,pentruareducetim-
puldeașteptare până la venireaapeicalde.Display-ulașează
temperaturadeturaapeideîncălziresauaapeicaldemenajere,
în funcție de cererea încurs. În timpul aprinderii arzătorului,ca
urmareauneicereridepreîncălzire,pedisplayesteașatsimbolul
(g.5b).Pentruadezactivafuncțiadepreîncălzire,rotițidinnou
butonul de reglare a temperaturii apei calde menajere pe simbolul
.Aducețibutonuldereglareatemperaturiiapeicaldemenajere
înpozițiadorită.FuncțianuesteactivăcucentralaînpozițiaOFF:
selectoruldefuncție(1g.1a)on OFF.
Ciao S R.S.I.:
Modul vară: activ numai cu boilerul extern racordat: rotind se-
lectorulpesimbolulvară (g.2a)seactiveazăfuncţiatradiţională
doarapăcaldămenajeră și centrala furnizeazăapălatempera-
turasetatăpeboiler.Încazuluneicererideapăcaldămenajeră,
display-uldigital indică temperatura apei calde menajereşi sunt
vizualizatesimboluldealimentarecuapăcaldăşisimbolulacără
Modul iarnă:rotindselectoruldefuncţiiîncadrulyoneimarcate
cu*şi-(g.2b),centralafurnizeazăapăpentruîncălzireși,dacă
este conectată la un boiler extern, apă caldă menajeră. În ca-
zul unei cereri de căldură,centrala pornește și display-ul digital
indicătemperaturaapeideîncălzireşisuntvizualizatesimbolulde
încălzireşi simbolulacără(g.3a).Încazuluneicereri deapă
caldă menajeră, display-ul digital indică temperatura apei calde
menajereşisuntvizualizatesimboluldealimentarecuapăcaldăşi
simbolulacără(g.4a).
Reglațitermostatuldeambientlatemperaturadorită(~20°C)
Ciao S C.S.I.: Reglarea temperaturii apei calde menajere
Pentruareglatemperaturaapeicaldemenajere(băi,duș,bucătărie
etc.),rotițibutonulmarcatcusimbolul (g.2b)încadrulzonei
marcatecu+și-.
Centralaseaăîntr-ostaredestand-bypânăcând,înurmaunei
cereride căldură,arzătorulseaprinde șidisplay-uldigital indică
temperaturaapei calde menajere şi sunt vizualizatesimbolul de
alimentarecuapăcaldăşisimbolulacără.Centralavarămâneîn
funcțiunepânăcândvoratinsetemperaturilereglate,dupăcare
vatrecedinnouînstareade“stand-by”.
Dacăseaprindeledulroșu,înconcordanțăcusimbolul pe pan-
ouldecomandăînseamnăcăcentralaseaăîntr-ostaredeoprire
temporară (vezi capitolulsemnalizări luminoase și anomalii). Pe
display-uldigitalesteașatcodulrespectiveianomalii(g.6a)
Ciao S R.S.I.: Reglarea temperaturii apei calde menajere
CAZUL Adoarîncălzire–nuseaplicăcalibrarea
CAZUL Bdoarîncălzire+boilerexterncutermostat–nuseaplică
calibrarea.
CAZUL Cdoarîncălzire+boilerexterncusondă–pentruaregla
66
ROMANA
temperaturaapeicaldedinboiler,rotițibutonulînsensulacelorde
ceasornicpentruacreștetemperaturașiînsensinverspentruao
diminua.
Centralaseaăîntr-ostaredestand-bypânăcând,înurmaunei
cereride căldură,arzătorulseaprinde șidisplay-uldigital indică
temperaturaapei calde menajere şi sunt vizualizatesimbolul de
alimentarecuapăcaldăşisimbolulacără.
Centralavarămâneînfuncțiunepânăcândvoratinsetemper-
aturilereglate,dupăcarevatrecedinnouînstareade“stand-by”.
Dacăseaprindeledulroșu,înconcordanțăcusimbolul pe pan-
ouldecomandăînseamnăcăcentralaseaăîntr-ostaredeoprire
temporară (vezi capitolulsemnalizări luminoase și anomalii). Pe
display-uldigitalesteașatcodulrespectiveianomalii(g.6a)
Ciao S C.S.I. - Ciao S R.S.I.: Funcția Sistem Automat de
Reglare a Ambientului (S.A.R.A.) g. 7a
Poziționândselectoruldetemperaturăaapeideîncălzireînsec-
torul evidențiat prin scrisulAUTO – valori de temperatură de la
55la 65°C-the S.A.R.A.seactivează sistemuldeautoreglare
S.A.R.A.: în baza semnalului de închidere a contactului termo-
statuluideambientcentralavariazăautomattemperaturaapeide
încălzire.Atuncicândtemperaturareglatăcuajutorulselectorului
detemperaturăapădeîncălzireesteatinsă,începeonumărătoare
de20minute.Dacăînacesttimp,termostatuldeambientcontinuă
săcearăcăldură,valoareadetemperaturăsetatăcreștecu5°C.
Dupăceafostatinsănouavaloare,începeoaltănumărătoarede
20minute.Dacăînacesttimp,termostatuldeambientcontinuăsă
cearăcăldură,valoareadetemperaturăsetatăcreștecu5°C.
Aceastăvaloarenouădetemperaturăreprezintăsumatemperatu-
riisetatemanualcuselectoruldetemperaturăapădeîncălzireșia
creșteriide+10°CafuncțieiS.A.R.A.
După al doilea ciclude creștere,temperatura estemenținută la
valoarea setată +10°C până când este satisfăcută cererea de
căldurădelatermostatuldeambient.
3A OPRIREA CENTRALEI
Oprirea temporară
Încazulabsențelortemporare,poziționațiselectoruldefuncție(1-
g.1a)pe (OFF).
Înacestmod,lăsândactivealimentareaelectricășialimentareacu
combustibil,centralaesteprotejatădesistemele:
- Anti-îngheț: atuncicând temperatura apeidin centrală scade
sub5°,pompadecirculaţieseactiveazăși,dacăestenecesar,
șiarzătorullaputereminimă,pentruareaducetemperaturaapei
lavaloridesiguranţă(35°C).Întimpulcicluluianti-îngheț,pedis-
playaparesimbolul .
- Anti-blocare pompă de circulație:unciclu de funcţionare se
activeazălaecare24oredepauză.
- Anti-îngheț ACM (doar când este conectat un boiler cu
sondă):funcțiaesteactivatăatuncicândtemperaturamăsurată
desondaboileruluiscadesub5°.Atunciestegeneratăocerere
decăldurăcupornirea arzătoruluilaputereminimă,careeste
menținutăpânăcândtemperaturaapeiatingevaloareade55°
C.Întimpulcicluluianti-îngheț,pedisplayaparesimbolul .
Oprirea pentru perioade lungi
Încazulabsențelortemporare,poziționațiselectoruldefuncție(1-
g.1a)pe (OFF).
Închidețirobineteledegazșideapăaleinstalațiilortermiceșisanitare.
Înacestcaz,funcțiaanti-înghețestedezactivată:golițiinstalațiile
dacăexistărisculdeîngheț.
4A VERIFICĂRI
Vericaţilaînceputulsezonuluicaşiîntimpulutilizăriicahidrome-
trulsăindicevaloridepresiune(cuinstalaţiarece)cuprinseîntre
0,6şi1,5baR:acestlucruevităzgomotulîninstalaţieprovocatdeaer.
Dacăcirculaţia apeiesteinsucientă,centralase opreşte.Înniciun
cazpresiuneaapeinutrebuiesăcoboaresub0,5bar(zonaroşie).
Încazcontrar,estenecesarsărestabiliţipresiuneaapei,astfel:
- poziţionaţiselectoruldefuncţii(2-g.1a)pe OFF
- deschideţirobinetuldeumplere(Lg.13pentruC.S.I.–extern
pentruR.S.I)pânăcândvaloareapresiunii este cuprinsă între
1 - 1,5 bar.
Închideţibinerobinetul.
Aduceţidinnouselectorulînpoziţiainiţială.
Dacăscădereapresiuniiestefrecventă,apelaţiCentruldeService
Autorizat.
5A SEMNALIZĂRI LUMINOASE ȘI ANOMALII
Pedisplay-uldigitalesteindicatăstareadefuncționareacentralei.
Tipuriledeașaresuntdescriseîntabeluldemaijos.
STARE CENTRALĂ DISPLAY
Stand-by -
Stare OFF OFF
AlarmăblocaremodulACF
A01
AlarmăanomalieelectronicăACF
A01
Alarmătermostatlimită
A02
Alarmăpresostatdeaer
A03
AlarmăpresostatH2O
A04
AnomaliesondăNTCACM(C.S.I.șiR.S.Idoar
cuboilerexterncusondă)
A06
AnomalieNTCîncălzire
A07
Flacărăparazit
A11
Reglareelectricăminimșimaximîncălzire
ADJ
Tranzitoriuînașteptareapornirii 88
°C
intermitent
Intervențiepresostatdeaer
intermitent
IntervențiepresostatH2O
intermitent
FuncțiePreîncălzireactivă(doarC.S.I.)
CereredecăldurăPreîncălzire(doarC.S.I.)
intermitent
Prezențăsondăexternă
CereredecăldurăACM 60
°C
Cererdecăldurăîncălzire 80
°C
Cererdecăldurăanti-îngheț
Flacărăprezentă
Pentru a restabili funcționarea (deblocare alarme): Anomalii
A 01-02-03
Poziționațiselectoruldefuncțiepe (OFF),așteptați5-6secund
șireaduceți-lînpozițiadorită (modulvară)sau
(moduliarnă).
Dacă tentativele de deblocare nu reactivează funcționarea,
solicitațiintervențiaCentruluideServiceAutorizat.
Anomalia A 04
Pelângăcoduldeanomalie,pedisplayesteașatșisimbolul .
Vericațivaloareapresiuniiindicatedetermomanometru:
dacă este sub 0,3bar, poziționați selectorul de funcție pe oprit
(OFF)șiacționațirobinetuldeumplere(Lg.13pentruC.S.I.
–extern pentru R.S.I.)pânăcândpresiunea ajungelaovaloare
cuprinsăîntre1și1,5bar.
Ulterior,aducețiselectoruldefuncțieînpozițiadorită (vară)sau
(iarnă).
Centralavaefectuauncicludeevacuareaaeruluicuduratăde
circa 2 minute.
În cazul în care căderile de presiune sunt frecvente, solicitați
intervențiaCentruluideServiceAutorizat.
Anomalia A 06
Centralafuncționeazănormaldarnugaranteazăstabilitateatem-
peraturiiapeicaldemenajerecarerămânesetatălaotemperatură
deaproximativ50°C.EstenecesarăintervențiaCentruluideSer-
vice Autorizat.
Anomalia A 07
SolicitațiintervențiaCentruluideServiceAutorizat.
CIAO S C.S.I. - CIAO S R.S.I.
67
DATE TEHNICE
DESCRIERE CIAO 20 S C.S.I. CIAO 24 S C.S.I. CIAO 24 S R.S.I.
Încălzire Puteretermicănominală kW
22,20 25,80 25,80
kcal/h 19.092 22.188 22.188
Puteretermicăutilă(80/60°) kW 20,60 23,94 23,94
kcal/h 17.717 20.590 20.590
Puteretermicăutilăredusă kW 7,00 8,90 8,90
kcal/h 6.020 7.654 7.654
Puteretermicăredusă(80°/60°) kW 5,88 7,52 7,52
kcal/h
5.057 6.468 6.468
ACM Puteretermicănominală kW
22,20 25,80 -
kcal/h 19.092 22.188 -
Puteretermicăutilă(*) kW 20,60 23,94 -
17.717 20.590 -
Puteretermicăredusă kW 7,00 8,90 -
kcal/h 6.020 7.654 -
Puteretermicăutilăminimă(*) kW 5,88 7,52 -
kcal/h 5.057 6.468 -
(*)valoaremedieîntrediversecondițiidefuncționareACM
Randament util Pn max - Pn min % 92,8-84,0 92,8-84,5 92,8-84,5
Randamentutil30%(47°retur) % 91,9 91,8 91,8
Randament de ardere % 93,2 93,2 93,2
Putereelectrică W
100 115 115
Categorie
II2H3B/P II2H3B/P II2H3B/P
Țarădedestinație RO RO RO
Tensiune de alimentare V - Hz 230-50 230-50 230-50
Graddeprotecție IP X5D X5D X5D
Pierderilacoșcuarzătorulpornit % 6,85 6,84 6,84
Pierderilacoșcuarzătoruloprit % 0,09 0,08 0,08
Încălzire
Presiune-Temperaturămaximă bar 3 - 90 3 - 90 3 - 90
Presiuneminimăpentrufuncționarestandard bar 0,25 - 0,45 0,25 - 0,45 0,25 - 0,45
CâmpdeselecțieatemperaturiiH2Oîncălzire °C 40/80 40/80 40/80
Pompă:sarcinămaximădisponibilăpentruinstalație mbar 300 300 300
la un debit de l/h 1.000 1.000 1.000
Vasdeexpansiunecumembrană l 7 8 8
Presarcinăvasdeexpansiune bar 1 1 1
ACM
Presiunemaximă bar 6 6 -
Presiuneminimă bar 0,15 0,15 -
Cantitatedeapăcaldăcu∆t25°C l/min
11,8 13,7 -
cu∆t30°C l/min 9,8 11,4 -
cu∆t35°C l/min 8,4 9,8 -
Debit minim ACM l/min 2 2 -
CâmpdeselecțieatemperaturiiH2Osanitare °C 37/60 37/60 -
Regulator de debit l/min 8 10 -
Presiune gaz
Presiunenominalăgazmetan(G20) mbar 20 20 20
PresiunenominalăgazlichidG.P.L.(G30/G31) mbar
30 30 30
Conexiuni hidraulice
Tur-returîncălzire Ø
3/4" 3/4" 3/4"
Intrare-ieșiresanitar Ø
1/2" 1/2" -
Tur-retur boiler Ø
- - 3/4"
Intrare gaz Ø 3/4" 3/4" 3/4"
Dimensiuni centrală
Înălțime mm 715 715 715
Lățime mm 405 405 405
Adâncimecarcasă mm
248 248 248
Greutatecentrală kg 29 31 28
Debit (G20)
Debit aer Nm
3/
h 36,875 39,743 39,743
Debit fum Nm
3
/h
39,101 42,330 42,330
Debitmasicfum(max-min) gr/s 13,310 - 14,540 14,360 - 15,600 14,360 - 15,600
Debit (G30)
Debit aer Nm
3/
h 35,328 38,545 38,545
Debit fum Nm
3
/h 36,955 40,436 40,436
Debitmasicfum(max-min) gr/s 13,100 - 14,030 14,330 - 15,730 14,330 - 15,730
68
ROMANA
DESCRIERE CIAO 20 S C.S.I. CIAO 24 S C.S.I. CIAO 24 S R.S.I.
Debit (G31)
Debit aer Nm
3/
h 36,405 39,385 39,385
Debit fum Nm
3
/h 38,119 41,378 41,378
Debitmasicfum(max-min) gr/s 13,480-14,280 14,620 - 16,210 14,620 - 16,210
Prestații ventilator
Sarcinărezidualăcentralăfărătuburi Pa 43 95 95
Tuburi evacuare fum concentrice
Diametru mm 60-100 60 - 100 60 - 100
Lungimemaximă m 4,25 4,25 4,25
Pierderiînurmainserăriiunuicotde45°/90° m 1 - 1,5 1 - 1,5 1 - 1,5
Orificiudetrecereprinperete(diametru) mm 105 105 105
Tuburi evacuare fum concentrice
Diametru mm
80-125 80-125 80-125
Lungimemaximă m 12,40 12,4 12,4
Pierderiînurmainserăriiunuicotde45°/90° m 1,35 - 2,2 1,35 - 2,2 1,35 - 2,2
Orificiudetrecereprinperete(diametru) mm 130 130 130
Tuburi evacuare fum separate
Diametru mm 80 80 80
Lungimemaximă m
10 + 10 16 + 16 16 + 16
Pierderiînurmainserăriiunuicotde45°/90° m
1,2 - 1,7 1,2 - 1,7 1,2 - 1,7
Instalație B22P-B52P
Diametru mm 80 80 80
Lungimemaximădeevacuare m 14 25 25
ClasăNOxe 3 3 3
Valori emisii la debit maxim și minim cu gaz G20*
Maxim-Minim CO mai mic de ppm 100-180 120 - 160 120 - 160
CO
2
% 7,1 - 2,0 7,3 - 2,3 7,3 - 2,3
NOx mai mic de ppm 180-100 160 - 100 160 - 100
FlueTemperaturăfum °C
127 - 97 141-108 141-108
Tabel multigaz
*VericareefectuatăcutubconcentricØ60-100-lungime0,85m–temperaturăapă80-60°C
DESCRIERE Gaz metan (G20) Butan (G30) Propan (G31)
IndiceWobbeinferior(la15°C-1013mbar) MJ/m
3
S 45,67 80,58 70,69
Presiunecaloricăutilă MJ/m
3
S 34,02 116,09 88
Presiunenominalădealimentare
mbar
(mmW.C.)
20
(203,9)
30
(305,9)
30
(305,9)
Presiuneminimădealimentare
mbar
(mmW.C.)
13,5
(137,7)
- -
Diafragmă(numărgăuri) 11 11 11
20 S C.S.I. 24 S C.S.I. 24 S R.S.I. 20 S C.S.I. 24 S C.S.I. 24 S R.S.I. 20 S C.S.I. 24 S C.S.I. 24 S R.S.I.
Diafragmă(diametrugăuri) mm 1,30 1,35 1,35 0,75 0,78 0,78 0,75 0,78 0,78
Debitgazmaximîncălzire Sm
3
/h 2,35 2,73 2,73
kg/h 1,75 2,03 2,03 1,72 2,00 2,00
Debit gaz maxim ACM Sm
3
/h 2,35 2,73 -
kg/h 1,75 2,03 - 1,72 2,00 -
Debitgazminimîncălzire Sm
3
/h 0,74 0,94 0,94
kg/h 0,55 0,70 0,70 0,54 0,69 0,69
Debit gaz minim ACM Sm
3
/h 0,74 0,94 -
kg/h 0,55 0,70 - 0,54 0,69 -
Presiunemaximăînjosulvaneideîncălzire mbar 10,40 11,80 11,80 28,00 27,80 27,80 36,00 35,80 35,80
mm W.C. 106,05 120,33 120,33 285,52 283,48 283,48 367,10 365,06 365,06
PresiunemaximăînjosulvaneideACM mbar 10,40 11,80 - 28,00 27,80 - 36,00 35,80 -
mm W.C. 106,05 120,33 - 285,52 283,48 - 367,10 365,06 -
Presiuneminimăînjosulvaneideîncălzire mbar 1,20 1,5 1,5 3,00 3,30 3,30 3,90 4,30 4,30
mm W.C. 12,24 15,30 15,30 30,59 33,65 33,65 39,77 43,85 43,85
PresiuneminimăînjosulvaneiACM mbar 1,20 1,5 - 3,00 3,30 - 3,90 4,30 -
mm W.C. 12,24 15,30 - 30,59 33,65 - 39,77 43,85 -
92
[HU] F Vezérlő panel
1 Funkciókapcsoló: Kikapcsolás(OFF)/Riasztó Reset
(újraindítás),
Nyár,
Tél/Fűtésihőmérsékletvizénekbeállítása
2 Használatimelegvízhőmérsékleténekbeállítása
Előmelegítőfunkció(gyorsabbmelegvíz-előállítás)(csakaC.S.I.
modellekesetén)
3 Víznyomásmérő
4 Dbdigitáliskijelző,amelyekrőlleolvashatóazüzemihőmérsékletés
a hibakódok
Azikonokmagyarázata
Berendezéstöltése:azikonazA04-eshibakóddalegyüttjelenikmeg
Hőszabályozás:akülsőérzékelőhözvalókapcsolódástjelzi
Lángőr:azikonazA01-eshibakóddalegyüttjelenikmeg
Hiba:üzemhibátjelez;ariasztáskóddalegyüttjelenikmeg
Fűtésüzemmód
Használati meleg víz üzemmód
Fagymentesítés:jelzi,hogyafagymentesítőfunkcióbevankapcsolva
Előmelegítés(gyorsabb melegvíz-előállítás): jelzi,hogy azelőmelegítő
funkcióbevankapcsolva(azégőfejüzemel)(csakaC.S.I.modellekesetén)
Fűtési/használatimelegvízhőmérsékletevagyüzemhiba
[RO] Panoul de comenzi
1 Selectordefuncţii: Stins(OFF)/Resetalarme,
Vară,
Iarnă/Reglareetemperaturăapă
încălzire
2 Reglaretemperaturăapămenajeră
Funcţiepreîncălzire(moddeproducereapăcaldămairapid)(doar
pentrumodeleleC.S.I.)
3 Hidrometru
4 Vizualizatordigitalcaresemnalizeazătemperaturadefuncţionareşi
codurile anomalie
Descrierea pictogramelor
Încărcareinstalaţie,aceastăpictogramăestevizualizatăîmpreună cu
codul anomalie A 04
Termoreglare:aşeazăconectarealaosondăexternă
Blocare acără,această pictogramăeste vizualizată împreunăcu
codul anomalie A 01
Anomalie: indicăorice anomalieîn funcţionareşi estevizualizată
împreunăcuuncoddealarmă
Funcţionareînmoddeîncălzire
Funcţionareapăcaldămenajeră
Anti-îngheţ:indicăfaptulcăesteînfuncţiuneciclulanti-îngheţ
Preîncălzire(moddeproducereapăcaldămairapid):indicăfaptul
căesteîndesfăşurareuncicludepreîncălzire(arzătorulesteaprins)
(doarpentrumodeleleC.S.I.)
Temperaturăîncălzire/apăcaldămenajerăsauanomalieînfuncţionare
[SL] Krmilna plošča
1 Izbirno stikalo funkcij: Izklop(OFF)/Resetiranjealarmov,
Poletje,
Zima/Regulacijatemperature
vode za ogrevanje
2 Regulacija temperature sanitarne vode
Funkcija predgrevanja(hitrejšapripravatople vode)(samopri
C.S.I.modelih)
3 Hidrometer
4 Digitalni prikazovalnik za prikaz delovne temperature in kod napak
Opis ikon
Polnjenje sistema, ta ikona se pojavi skupaj s kodo napake A 04
Toplotnaregulacija:označujepovezavozzunanjimtipalom
Prekinitev plamena, ta ikona se pojavi skupaj s kodo napake A 01
Napaka:označujevsakonapakovdelovanjuinsepojaviskupajs
kodo alarma
Delovanju ogrevanja in
Delovanju priprave sanitarne vode
Zaščitapredzamrznitvijo:označuje,dadelujezaščitapredzamrznitvijo
Predgrevanje(hitrejšapripravatoplevode):označuje,dajevteku
cikluspredgrevanja(gorilnikdeluje)(samosC.S.I.modeli)
Temperatura ogrevanja/sanitarne vode ali napaka v delovanju
[DE] Bedienfeld
1 Funktionswahlschalter: Aus(OFF)/ResetAlarme,
Sommer,
Winter/Einstellung der
Wassertemperatur der Heizung
2 Einstellung der Temperatur des Sanitärwassers
Vorwärm-Funktion(schnellerwarmes Wasser) (nurbei C.S.I.
Modellen)
3 Hydrometer
4 DigitaleAnzeigefürBetriebstemperaturundStörungscodes
BeschreibungderSymbole
Befüllen derAnlage: diesesSymbol wird zusammenmit dem
StörungscodeA04angezeigt
Temperaturregelung: gibt die Verbindung zu einem externen Fühler
StörabschaltungderFlamme:diesesSymbolwirdzusammenmitdem
StörungscodeA01angezeigt
Störung:bezeichnet einebeliebige Funktionsstörungund wird
zusammen mit einem Alarmcode angezeigt
Heizbetrieb
Sanitärbetrieb
Frostschutz:gibtan,dasseinFrostschutzzyklusläuft
Vorwärmung(schnellerwarmesWasser):gibtan,dasseinVorrmzyklus
läuft(derBrenneristeingeschaltet)(nurbeiC.S.I.Modellen)
TemperaturHeizung/SanitäroderFunktionsstörung
92
[DE] FUNKTIONELLE ELEMENTE DES
KESSELS
1 Füllventil
2 Abussventil
3 3-Wege-Ventil
4 Sicherheitsventil
5 Fühler NTC Sanitär
6 Umwälzpumpe
7 Entlüftungsventil
8 Brenner
9 Zündelektrode-Flammenermittlung
10 Grenzthermostat
11 Primärer Fühler NTC
12 Gebläse
13 Unterdruckmessrohr
14 Rauchansch
15 Differential-Druckwächter Rauch
16 Ausdehnungsgefäß
17 Wärmetauscher
18 DruckwächterHeizung
19 Gasventil
20 Wärmetauscher für Sanitärbereich
21 Flusswächter
[SL] FUNKCIONALNI ELEMENTI KOTLA
1 Ventil za polnjenje
2 Izpustni ventil
3 Trismerni ventil
4 Varnostni ventil
5 NTC tipalo sanitarne vode
6 Pretočnačrpalka
7 Odzračevalniventil
8 Gorilnik
9 Elektrodazavžig-zaznavanjeplamena
10 Mejni termostat
11 Primarna NTC tipalo
12 Ventilator
13 Cev za zaznavanje podtlaka
14 Dimniška prirobnica
15 Diferenčnitlačniventiladimnihplinov
16 Ekspanzijska posoda
17 Toplotni izmenjevalnik
18 Tlačniventilogrevanja
19 Ventil plina
20 Toplotni izmenjevalnik sanitarne vode
21 Pretočniventil
[PT] ELEMENTOS FUNCIONAIS DA CALDEIRA
1 Válvula de enchimento
2 Válvula de descarga
3 Válvula 3 vias
4 Válvula de segurança
5 Sonda NTC sanitário
6 Bomba de circulação
7 Válvuladedesgasicação
8 Queimador
9 Eléctrodo acendimento-observação da chama
10 Termóstato de limite
11 Sonda NTC primário
12 Ventilador
13 Tubovericaçãodedepressão
14 Flange de fumos
15 Pressostato fumos diferencial
16 Vaso de expansão
17 Permutador
18 Pressostatodeaquecimento
19 Válvula do gás
20 Intercambiador sanitário
21 Fluxostato
[HU] KAZÁN FUNKCIONÁLIS RÉSZEI
1 Vízfeltöltőcsap
2 Leeresztőcsap
3 Háromutas szelep
4 Biztonsági szelep
5 HasználatimelegvízNTCérzékelő
6 Cirkulációsszivattyú
7 Légtelenítőszelep
8 Égő
9 Gyújtó-lángőrelektróda
10 Határoló termosztát
11 PrimérNTCérzékelő
12 Ventillátor
13 Depresszióérzékelőcső
14 Füstgáz csatlakozó perem
15 Differenciális füstgáz presszosztát
16 Tágulásitartály
17 Hőcserélő
18 Fűtésipresszosztát
19 Gázszelep
20 Használatimelegvízhőcserélője
21 Áramlásszabályozó
[RO] ELEMENTE FUNCŢIONALE CAZAN
1 Robinet umplere
2 Robinet golire
3 Vanăcu3căi
4 Valvăsiguranţă
5 SondăNTCcirc.menajer
6 Pompăcirculaţie
7 Supapăsuprapresiune
8 Arzător
9 Electrodaprindere-detectareacără
10 Termostat limitator
11 SondăNTCcirc.primar
12 Ventilator
13 Tub detectare depresurizare
14 Flanşăgazeardere
15 Presostatgazediferenţialù
16 Vas expansiune
17 Schimbător
18 Presostatîncălzire
19 Valvăgaz
20 Schimbătorcircuitdeapăcaldămenajeră
21 Fluxostat
92
[SL] HIDRAVLIČNI SISTEM
A Povratni vod ogrevanja
B Dvižnivodogrevanja
C Voda iz grelnika sanitarne vode
D Voda v grelnik sanitarne vode
E Izhod tople vode
F Vhod hladne vode
1 Vstop sanitarne vode
2 Izstop sanitarne vode
3 Izstop ogrevalne vode
4 Povrat ogrevalne vode
5 Protipovratni ventil
6 Izpustni ventil
7 Varnostni ventil
8 By-pass
9 Trismerni ventil
10 Pretočnačrpalkazodzračevanjem
11 Odzračevalniventil
12 Ekspanzijska posoda
13 Primarna NTC tipalo
14 Toplotni izmenjevalnik
15 Tlačniventilvode
16 Gorilnik
17 Toplotni izmenjevalnik sanitarne vode
18 NTCtipalosanitarnevode
19 Ventil za polnjenje
20 Omejevalnik pretoka
21 Pretočniventil
22 Filter
23 Grelniksanitarnevode(dodatnaoprema)
[DE] WASSERKREIS
A Heizungsrückkehr
B Heizungsdruckleitung
C Boilerrückkehr
D Boilerdruckleitung
E Ausgang warmes Wasser
F Eingang kaltes Wasser
1 Eingang Sanitär
2 Ausgang Sanitär
3 Vorlauf Heizung
4 Rücklauf Heizung
5 Rückschlagventil
6 Abussventil
7 Sicherheitsventil
8 Bypass
9 3-Wege-Ventil
10 Umwälzvorrichtung mit Entlüftung
11 Entlüftungsventil
12 Ausdehnungsgefäß
13 Primärer Fühler NTC
14 Wärmetauscher
15 Druckwächter Wasser
16 Brenner
17 Wärmetauscher für Sanitärbereich
18 FühlerNTCSanitär
19 Füllventil
20 Durchsatzbegrenzer
21 Flusswächter
22 Filter
23 Kessel(aufAnfragelieferbar)
[PT] CIRCUITO HIDRÁULICO
A Retorno do aquecimento
B Descarga do aquecimento
C Retorno do boiler
D Descarga do boiler
E Saída da água quente
F Entrada da água fria
1 Entrada sanitário
2 Saída sanitário
3 Envio aquecimento
4 Retorno aquecimento
5 Válvula de não retorno
6 Válvula de descarga
7 Válvula de segurança
8 By-pass
9 Válvula de 3 vías
10 Circulador com respiro
11 Válvuladedesgasicação
12 Vaso de expansão
13 Sonda NTC primário
14 Permutador
15 Pressostato da água
16 Queimador
17 Intercambiador sanitario
18 SondaNTCsanitário
19 Válvula de enchimento
20 Limitador de vazão
21 Fluxostato
22 Filtro
23 Boiler(quepodeserfornecidoapedido)
[HU] VÍZKERINGETÉS
A Fűtésvisszatérőág
B Fűtéselőremenőág
C Tárolóvisszatérőág
D Tárolóelőremenőág
E Meleg víz kimenet
F Hideg víz bemenet
1 Használati melegvíz bemenet
2 Használati melegvíz kimenet
3 Fűtéselőremenőága
4 Fűtésvisszatérőága
5 Visszacsapó szelep
6 Leeresztőcsap
7 Biztonsági szelep
8 By-pass
9 Háromutas szelep
10 Keringetőszivattyúszellőzőnyílással
11 Légtelenítőszelep
12 Tágulásitartály
13 PrimérNTCérzékelő
14 Hőcserélő
15 Víz presszosztát
16 Égő
17 Használatimelegvízhőcserélője
18 HasználatimelegvízNTCérzékelő
19 Vízfeltöltőcsap
20 Hozam limiter
21 Áramlásszabályozó
22 Szűrő
23 Tároló(különmegrendelésre)
[RO] CIRCUIT HIDRAULIC
A Retur incalzire
B Tur incalzire
C Retur boiler acumulare
D Tur boiler acumulare
E Iesire apa calda
F Intrare apa rece
1 Intrare circ. menajer
2 Ieşirecirc.menajer
3 Turîncălzire
4 Returîncălzire
5 Valvăunidirecţională
6 Robinet golire
7 Valvăsiguranţă
8 By-pass
9 Vanăcu3căi
10 Circultorcuvalvăpurjare
11 Supapăsuprapresiune
12 Vas expansiune
13 SondăNTCcirc.primar
14 Schimbător
15 Presostatapă
16 Arzător
17 Schimbătorcircuitdeapăcaldămenajeră
18 SondăNTCcirc.menajer
19 Robinet umplere
20 Limitator de debit
21 Fluxostat
22 Filtru
23 Boileracumulare(disponibillacerere)
91
CIAO S C.S.I. - CIAO S R.S.I.
[F] PLAQUE D'IMMATRICULATION
Fonction sanitaire
Fonction chauffage
Qn Débit thermique
Pn Puissance thermique
IP Degré de protection
Pmw Pression d'exercice maximum sanitaire
Pms Pression maximum chauffage
T Température
η Rendement
D Débitspécique
NOx Classe NOx
[ES] TARJETA DE LA MATRÍCULA
Función sanitaria
Función calefacción
Qn Potencia máxima nominal
Pn Potenciamáximaútil
IP Grado de protección
Pmw Presión máxima agua sanitaria
Pms Presión máxima calefacción
T Temperatura
η Rendimiento
D Caudalespecíco
NOx Clase NOx
[PT] ETIQUETA MATRÍCULA
Função sanitária
Função aquecimento
Qn Capacidade térmica
Pn Potência térmica
IP Grau de protecção
Pmw Máxima pressão de exercício sanitário
Pms Máxima pressão de aquecimento
T Temperatura
η Rendimento
D Vazãoespecíca
NOx Classe NOx
[HU] REGISZTRÁCIÓS CÍMKE
Használati melegvíz funkció
Fűtésifunkció
Qn Hőterhelés
Pn Hőteljesítmény
IP Védelmi fok
Pmw Használatimelegvízmaximálisnyomása
Pms Fűtésmaximálisnyomása
T Hőmérséklet
η Hatásfok
D Specikusterhelés
NOx NOxosztály
[RO] ETICHETĂ MATRICOLĂ
Funcţieapămenajeră
Funcţieîncălzire
Qn Capacitatetermică
Pn Puteretermică
IP Graddeprotecţie
Pmw
Presiunemaximădefuncţionarecirc.menajer
Pms Presiunemaximăîncălzire
T Temperatură
η Randament
D Capacitatespecică
NOx ClasăNOx
[DE] KENNSCHILD
Funktion Sanitär
Funktion Heizung
Qn Wärmedurchsatz
Pn Wärmeleistung
IP Schutzart
Pmw Maximaler Betriebsdruck Sanitär
Pms Maximaler Druck Heizung
T Temperatur
η Leistung
D SpezischerDurchsatz
NOx Klasse NOx
[SL] TABLICA SERIJSKE ŠTEVILKE
Funkcija sanitarne vode
Funkcija ogrevanja
Qn Toplotna zmogljivost
Pn Toplornamoč
IP Stopnjazaščite
Pmw Maksimalni delovni tlak sanitarne vode
Pms Minimalni tlak ogrevanja
T Temperatura
η Izkoristek
D Specičnazmogljivost
NOx Razred NOx
[EN] SERIAL NUMBER PLATE
Domestic hot water operation
Heating function
Qn Nominalcapacity
Pn Nominal power
IP Protection level
Pmw Domestic hot water maximum pressure
Pms Heating maximum pressure
T Temperature
η Workingefciency
D Speciccapacity
NOx NOx Value class
Qn =
Ciao S 24 R.S.I.
N.
00000000000
230 V ~ 50 Hz W
****
NOx:
IP
Pms = T= °C
Pn =
η
set at:
calibrado:
engestellt auf:
réglage:
dostosowane do:
Pmw = bar T= °C
Qn =
Ciao S 20 C.S.I.
0694/00
N.
00000000000
230 V ~ 50 Hz W
****
NOx:
D: l/min
IP
Pms = bar T= °C
Pn =
B22P-B52P-C12-C22-C32-C42-
C52-C62-C82-C92-C12x-C32x-
C42x-C52x-C62x-C82x-C92x
η
set at:
calibrado:
engestellt auf:
réglage:
dostosowane do:
92
[EN] AMBIENT THERMOSTAT CONNECTION
T.A. Ambient thermostat
A The ambient thermostat (24Vdc) should be
connected as indicated in the diagram once the
U-boltonthe2-wayconnector(CN5)hasbeen
removed.
Warning
TAinputinsafetylowvoltage.
B Low voltage devices should be connected to
connectorCN6-M4,asshowninthegure.
C.R. Remote control
SE External probe
TBOLL Boiler thermostat or domestic water
timeprogrammer(POS)
SBOLL Storage tank
A
B
T.A.
[F] BRANCHEMENT DU THERMOSTAT D'AM-
BIANCE
T.A. Thermostat d'ambiance
A Le thermostatd'ambiance (24Vdc) sera
inséré,comme indiqué dans le schéma, après
avoir enlevé le cavalier présent sur le connec-
teurà2voies(CN5).
Attention
Entrée TA à basse tension de sécurité.
B Les dispositifs de basse tension seront bran-
chés sur le connecteur CN6-M4, comme
indiquésurlagure.
C.R. commande à distance
SE sonde externe
TBOLL Thermostat chaudière ou program-
mateurhoraired'eausanitaire(POS)
SBOLL Sonde du chauffe-eau
[ES] CONEXIÓN DEL TERMOSTATO AMBIENTE
T.A. Termostato ambiente
A Eltermostatoambiente(24Vdc)seinstalará
como se indica en el esquema después de
quitarelpuentedelconectorde2vías(CN5).
Atención
Entrada TA con baja tensión de seguridad.
B Los dispositivos de baja tensión se conec-
tarán en el conector CN6-M4, como indica
lagura.
C.R. mando a distancia
SE sonda exterior
TBOLL Termostato de caldera o programa-
dordetiempodeaguasanitaria(POS)
SBOLL Sonda interacumulador
[PT] CONEXÃO TERMÓSTATO AMBIENTE
T.A. Termóstato ambiente
A Iltermóstatoambiente(24Vdc)seráactivado
como indicado pelo esquema depois de ter
tirado a forquilha presente no conector 2 vias
(CN5).
Atenção
Entrada TA em baixa tensão de segurança.
B As utilizações de baixa tensão serão ligadas
comoindicadonaguranoconectorCN6-M4.
C.R. comando remoto
SE sonda externa
TBOLL Termóstato de caldeira ou programa-
dordetempodeáguasanitária(POS)
SBOLL Sonda do boiler
T. BOLL.
O POS
−t°
S.
BOLL.
M4
[HU] SZOBATERMOSZTÁT CSATLAKOZTATÁSA
T.A. Szobatermosztát
A Aszobatermosztátot(24Vdc)arajzonlátható
módon kell csatlakoztatni, miután a kétutas
csatlakozóról(CN5)levetteabilincset.
Figyelem
Szobatermosztát (TA) bemenetbiztonsági
alacsonyfeszültségbe.
B Az alacsonyfeszültségű alkalmazásokat,
az ábrán látható módon kell csatlakoztatni
a CN6-M4 csatlakozáshoz.
C.R. távvezérlés
SEkülsőérzékelő
TBOLL Kazántermosztát vagyhasználati
vízidőprogramozója(POS)
SBOLLTárolóérzékelő
[RO] CUPLAREA TERMOSTATULUI DE
AMBIANŢĂ
T.A. Termostatambianţă/climă
A Termostatuldeclimă(24Vdc)sevacuplaaşa
cumreiese dinschemă, dupăîndepărtarea
puncţiidepeconectorulcu2căi(CN5).
Atenţie
IntrareaTAîntensiunemică,desiguranţă.
B Consumatoriicutensiunemicăvorcuplaţi
aşacumsearatăîng.conectoruluiCN6-M4.
C.R.telecomandă
SEsondăexternă
TBOLL Termostar boiler sau programator
orarACM(POS)
SBOLL Sonda boiler
[DE] ANSCHLUSS DES RAUMTHERMOSTATS
T.A. Raumthermostat
A Das Raumthermostat(24Vdc) wird wieim
Schema angegeben eingefügt, nachdem der
Bügelbolzenam 2-Wege-Verbinder(CN5)
entfernt wurde.
ACHTUNG
Eingang des TA für Sicherheits-Niederspan-
nung
B Niederspannungsgeräte müssen an den
Verbinder CN6-M4 wie in der Abbildung
gezeigt angeschlossen werden.
C.R. Fernsteuerung
SE Außenfühler
TBOLL Kesselthermostat oder Brauchwas-
ser-Timer(POS)
SBOLL Wasserspeicher
[SL] POVEZAVA S TERMOSTATOM OKOLJA
T.A. Termostat okolja
A lTermostatokolja (24Vdc)sepriklopi kotje
prikazanonashemi,kosteodstranilimostiček,
kisenahajanadvosmernemspojniku(CN5).
Popzor
Nizkonapetostni varnostni vhod TA.
B Nizkonapetostni porabnikisepovežejo s
spojnikom CN6-M4 kot je prikazano na sliki.
C.R. daljinski upravljalnik
SE zunanja tipalo
TBOLLTermostatgrelnikavodealičasovni
programatortoplesanitarnevode(POS)
SBOLL Tipalo grelnika sanitarne vode
CIAO S C.S.I.
CIAO S R.S.I.
CIAO S C.S.I.
CIAO S R.S.I.
CIAO S R.S.I.
92
[PT] A polarização “L-N” é recomendada
Blu=Blue / Marrom=Brown / Preto=Black /
Vermelho=Red/ Branco=White / Violeta=Violet /
Cinza=Grey/
A = Conexão termóstato ambiente baixa tensão 24V
B = Válvula do gás
C = Eléctrodo A/R
D = Fusível 3.15A F
MP Cartão de controlo com mostrador digital e transfor-
mador de ignição integrado
P1 Potenciómetro selecção off - verão - inverno – reset
/ temperatura aquecimento
P2 Potenciómetro selecção set point sanitário
P3 Potenciómetro selecção curvas termo-regulação
JP1 Ponte habilitação manípulo para a calibragem
JP2 Ponte zeramento timer aquecimento e memorização
máximo eléctrico aquecimento em calibragem
JP3 Ponte selecção MTN - GPL
JP4 Selector termóstatos sanitário absolutos
JP5 Ponte selecção e funcionamento somente aqueci-
mento(nãoutilizado)
JP6Habilitaçãogestãouxostato(nãoutilizado)
CN1÷CN13
Conectores de conexão
F1 Fusível 2A T
F Fusível externo 3.15A F
M3 Régua de terminais para conexões externas
T.A. Termóstato ambiente
E.A./R. Eléctrodo acendimento / observação
TR1 transformador de acendimento remoto
V Ventilador
P.F. Pressostato fumos
S.R.Sonda(NTC)temperaturacircuitoprimário
T.L. Termóstato limite
OPE Operador válvula gás
P Bomba
3V Servomotor válvula 3 vias
F.L. Fluxostato sanitário
S.S.Sonda(NTC)temperaturacircuitosanitário
PAPressostatoaquecimento(água)
MOD Modulador
[HU] Ajánlatos az “L-N” (fázis-semleges) polarizáció
Kék=Blue / Barna=Brown / Fekete=Black / Piroa=Red
/Fehér=White/Lila=Violet/Szürke=Grey/
A= 24V alacsonyfeszültségű szobatermosztát
áthidalása
B = Gázszelep
C=A/R(Gyújtó-lángőr)elektróda
D = Olvadóbiztosíték 3.15A F
MPVezérlőkártya digitáliskijelzéssel és integrált
gyújtástranszformátorral
P1kikapcsolva(off)- nyár -tél –reset / hőmérséklet
fűtéskiválasztásánakpotenciométere
P2 Használati melegvíz set point kiválasztásának a
potenciométere
P3Hőmérsékletszabályozásigörbe kiválasztásának a
potenciométere
JP1 Kalibráló gomb jumperje
JP2Fűtésidőlenullázóésmaximáliselektromosfűtés
tárolás kalibrálásának jumperje
JP3Metángáz-GPL(cseppfolyósítottszénhidrogén-gáz)
kiválasztás jumperje
JP4 Teljes használati melegvíz termosztátok szelektor
jumperje
JP5csak a fűtésfunkciókiválasztás jumperje (nincs
használatban)
JP6
Áramlásszabályozó
vezérlésénekjumperje(nincs
használatban)
CN1÷CN13
csatlakozók a csatlakozáshoz
F1 Olvadóbiztosíték T 2A
FKülsőolvadóbiztosítékF3.15A
M3 Kapocsléc külsőcsatlakozáshoz
T.A. Szobatermosztát
E.A./R.Gyújtó-lángőrelektróda
TR1Távgyújtástranszformátora
V Ventillátor
P.F. Füstgáz preszosztát
S.R.Primérhőmérsékletérzékelő(NTC)
T.L. Határoló termosztát
OPE Gázszelep
PSzivattyú
3VSzervomotorháromágúszelepe
F.L.Használatimelegvízáramlásszabályozója
S.S.Használatimelegvízhőmérsékletérzékelője(NTC)
PAFűtéspresszosztátja
MODModulátor(szabályozó)
[RO] Se recomandă polarizarea "L-N”
Bleumarin=Blu / Maron=Brown / Negru=Black /
Roşu=Red/Alb=White/Violet=Violet/Gri=Grey/
B=Valvăgaz
A=Puntetermostatambianţăjoasătensiune24V
C = Electrod A/R
D=Rezistenţă3.15AF
MP Placădecomandăcuaşajdigitalşitransformator
de aprindere integrat
P1Potenţometruselectareoff-vară-iarnă–reset/
temperaturăîncălzire
P2Potenţometruselectaresetpointcircuitmenajer
P3Potenţometruselectarecurbetermoreglare
JP1Punteabilitaremanete/buşoaneptrcalibrare
JP2Punte resetare timerîncălzireşi memorizare
valoareamaximă electrică laîncălzire înmomentul
calibrării
JP3 Punte selectare MTN - GPL
JP4 Selector termostate circuit menajer absolute
JP5Punte selectare funcţionarenumai încălzire
(neutilizată)
JP6Abilitaregestiuneuxostat(neutilizată)
CN1÷CN13
Conectori ptr conectare
F1Rezistenţă2AT
FRezistenţăexternă3.15AF
M3 Cutie borne ptr conexiuni externe
T.A.Termostatambianţă/climă
E.A./R. Electrod aprindere / detectare
TR1 Transformator aprindere telecomandat
V Ventilator
P.F. Presostat gaze
S.R.Sondă(NTC)temperaturăcircuitprimar
T.L. Termostat limitator
OPEOperatorvalvăgaz
PPompă
3VServomotorvanăcu3căi
F.L. Fluxostat circ. menajer
S.S.Sondă(NTC)temperaturăcircuitmenajer
PAPresostatîncălzire(apă)
MOD Modulator
[DE] “L-N” Die Polarisierung “L-N” wird empfohlen
Blau=Blue / Braun=Brown / Schwarz=Black /
Rot=Red/ Weiß=White / Violett=Violet /
Grau=Grey/
B = Gasventil
A = Übebrückung f. Raumthermostat Niederspannung 24V
C = Elektrode A/R
D = Sicherung 3.15A F
MP Steuerplatine mit Digitalanzeige und integriertem
Zündtransformator
P1 Potentiometer zur Auswahl Off - Sommer - Winter –
Reset / Heiztemperatur
P2 Potentiometer zur Auswahl des Sanitär-Sollwerts
P3 Potentiometer zur Auswahl der Kurven der Tempe-
raturregelung
JP1 Überbrückung zur Aktivierung der Kugelgriffe zum
Einstellen
JP2 Überbrückung zum Nullsetzen des Timers für Hei-
zung und Speicherung maximale elektrische Heizung
in Einstellung
JP3 Überbrückung zur Auswahl von MTN - Flüssiggas
JP4 Wahlschalter der Sanitär-Absolutthermostate
JP5 Überbrückung zur Auswahl des reinen Heizbetriebs
(nichtverwendet)
JP6 Aktivierung der
Flusswächter
(nichtverwendet)
CN1÷CN13
Anschlussverbinder
F1 Sicherung 2A T
F Externe Sicherung 3.15A F
M3 Klemmleiste für externe Anschlüsse
T.A. Raumthermostat
E.A./R.Zündelektrode/Messung
TR1FerngesteuerterZündtransformator
V Gebläse
P.F. Druckwächter Rauch
S.R.Fühler(NTC)TemperaturPrimärkreis
T.L. Grenzthermostat
OPE Bediener Gasventil
P Pumpe
3V Stellmotor Des 3-Wege-Vetils
F.L. Flusswächter Sanitär
S.S.Fühler(NTC)TemperaturSanitärkreis
PADruckwächterHeizung(Wasser)
MOD Modulator
[SL] Polarizacija “L-N” je priporočljiva
Modra=Blue/Rjava=Brown/Črna=Black/Rdeča=Red/
Bela=White/Vijolična=Violet/Siva=Grey/
B = Ventil plina
A=Mostičeknizkonapetostnegatermostataprostora
24V
C = Elektroda A/R
D = Varovalka 3.15A F
MP Krmilna kartica z digitalnim prikazovalnikom in
vgrajenimtransformatorjemvžiga
P1 Potenciometer izbire off - poletje - zima – reset /
temperatura ogrevanja
P2 Potenciometer izbire nastavitve sanitarne vode
P3 Potenciometer izbire krivulje toplotne regulacije
JP1Mostičekzavklopnastavitvenihgumbov
JP2Mostičekzaizbrisčasovnikaogrevanjainpomnilnika
maksimalne porabe toka ogrevanja med umerjanjem
JP3MostičekizbireMETAN-UTEKOČINJENI
JP4 Izbira termostatov sanitarne vode
JP5Mostiček zaizbirodelovanja samoza ogrevanje
(niuporabljen)
JP6 Vklop upravljanja
pretočniventil
(niuporabljen)
CN1÷CN13
Spojniki za povezavo
F1 Varovalka 2A T
FZunanjavarovalka3.15AF
M3 Spojna letev za zunanje povezave
T.A. Termostat v prostoru
E.A./R.Elektrodazavžig/zaznavanje
TR1Transformatorzadaljinskivžig
V Ventilator
P.F.Tlačniventildimnihplinov
S.R.tipalo(NTC)temperatureprimarnegakrogotoka
T.L. Mejni termostat
OPE Krmilnik plinskega ventila
PČrpalka
3V Servomotor 3 smernega ventila
F.L.Pretočniventilsanitarnevode
S.S.Tipalo(NTC)temperaturekrogotokasanitarnevode
PATlačniventilogrevanja(voda)
MOD Modulator
CIAO S R.S.I.
92
[PT] “L-N” - A polarização “L-N” é recomendada
Blu=Azul escuro / Marrone=Marrom / Nero=Preto /
Rosso=Vermelho/ Bianco=Branco / Viola=Violeta /
Grigio=Cinza / Arancione=Laranja
A = Jumper do termóstato ambiente de baixa tensão 24 V
B = Válvula de gás
C = Eléctrodo I/D
D = Fusível 3,15 A F
MP Placa de controlo
P1 Potenciómetro para seleccionar - verão - inverno –
desbloqueio / aquecimento de temperatura
P2 Potenciómetro para seleccionar o ponto de ajus-
te da água quente sanitária
P3 Potenciómetro para seleccionar a curva de regu-
lação de temperatura
JP1 Ponte para habilitar os manípulos para calibragem
JP2 Ponte para desbloquear o temporizador de
aquecimento e registar o aquecimento eléctrico má-
ximo na calibragem
JP3 Ponte para seleccionar MTN - LPG
JP4 Selector termóstato água quente sanitária ab-
soluto
JP5 Selecção de função de somente aquecimento
da ponte com provisão para caldeira externa com
termóstato ou sonda
JP6 não utilizado
F1 Fusível 2 A T
F Fusível externo 3.15A F
Régua de terminais M3 para conexões externas: 230 V
M4 Régua de terminais para conexões externas:
sonda da caldeira/termóstato da caldeira ou progra-
madorhoráriosanitário(POS)
T.A. Termóstato ambiente
E.A./R. Eléctrodo de acendimento/detecção
TR1 Transformador de ignição remoto
V Ventilador
P.F. Pressostato de gás da chaminé
S.R.Sondadetemperaturadocircuitoprimário(NTC)
T.L. Termóstato de limite
OPE Operador da válvulas do gás
P Bomba
3 V Válvula do servomotor de 3 vias
T.BOLL Termóstato do depósito de água
POS programador de tempo de água sanitária
S.BOLL. Reservatório de armazenamento
PAPressostatodeaquecimento(água)
Modulador MOD
Conectores CN1÷CN13
[DE] Die “L-N” Polarisierung wird empfohlen
Blu=Blau / Marrone=Braun / Nero=Schwarz /
Rosso=Rot/ Bianco=Weiß / Viola=Violett /
Grigio=Grau
/ Arancione=Orange
A = 24V Niederspannung Drahtbrücke für Raumther-
mostat
B = Gasventil
C=Zünd/Flammenerkennungselektrode
D = Sicherung 3.15A F
MP Steuerplatine
P1 Potentiometer für Auswahl Aus - Sommer - Win-
ter – Rückstellung / Heizungstemperatur
P2 Potentiometer für die Auswahl des BWW-Sollwerts
P3 Potentiometer für die Auswahl der Temperatur-
regelungskurve
JP1DrahtbrückefürdieAktivierungderStellknöpfe
JP2 Drahtbrücke für die Rückstellung der Heizungs-
zeitschaltuhr und Speicherung der Höchstleistung
der Elektroheizung in der Einstellphase
JP3 Drahtbrücke für Auswahl MTN - FLÜSSIGGAS
JP4 Wahlschalter für absoluten Brauchwarmwasser-
thermostat
JP5 Drahtbrücke für Auswahl nur Heizbetrieb mit Vor-
rüstung für externen Kessel mit Thermostat oder Fühler
JP6 nicht verwendet
F1 Sicherung 2A T
F Externe Sicherung 3.15A F
M3 Klemmleiste für externe Anschlüsse 230V
M4 Klemmleiste für externe Anschlüsse: Kessel/
ThermostatfühlerKesseloderBWW-Timer(POS)
T.A. Raumthermostat
E.A./R.Zünd-/Flammenerkennungselektrode
TR1FerngesteuerterZündtransformator
V Gebläse
P.F. Abgasdruckwächter
S.R.-Primärkreis-Temperaturfühler(NTC)
T.L. Grenzthermostat
OPE Stellantrieb Gasventil
P Pumpe
3V 3-Wege Ventil des Stellantriebs
T.BOLL Wasserspeicherthermostat
POS Brauchwasser-Timer
S.BOLL. Wasserspeicher
PA Heizwasserdruckwächter
MOD Modulator
CN1÷CN13 Verbinder
[HU] Ajánlott az „L-N” - „L-N” polarizáció
Blu=Kék / Marrone=Barna / Nero=Fekete /
Rosso=Piros/ Bianco=Fehér / Viola=Lila /
Grigio=Szürke / Arancione=Narancs
A=24Valacsonyfeszültségűszobatermosztátáthi-
dalása
B = Gázszelep
C = I/D elektróda
D = Olvadóbiztosíték, 3,15 A F
MPVezérlőkártya
P1Ki–nyár–tél–visszaállítás/fűtésihőmérséklet
választó potenciométer
P2 A használati melegvíz alapérték választásának
potenciométere
P3Ahőmérséklet-szabályozásigörbeválasztásának
potenciométere
JP1 Kalibráló gombok jumperje
JP2 Fűtés időlenullázó és maximális elektromos
fűtéstároláskalibrálásánakjumperje
JP3Metángáz-GPL(cseppfolyósítottszénhidrogén-
gáz)választásjumperje
JP4 Abszolút használati melegvíz termosztátok
választókapcsolója
JP5Jumperacsakfűtésfunkcióválasztásához,ha
vankülsőkazántermosztáttalvagyérzékelővel
JP6 nincs használatban
F1 2A T olvadóbiztosíték
F3,15AFkülsőolvadóbiztosíték
M3Sorkapocskülsőcsatlakozásokhoz:230V
M4 Morsettiera per collegamenti esterni: sonda bol-
litore/termostato bollitore o programmatore orario
sanitario(POS)
T.A. Szobatermosztát
E.A./R.Gyújtó-lángőrelektróda
TR1Távgyújtástranszformátora
V Ventilátor
P.F.Füstgáznyomáskapcsoló
S.R.Primeráramkörhőmérsékletérzékelő(NTC)
T.L. Határoló termosztát
OPEGázszelep-kezelő
PSzivattyú
3VHáromjáratúszervomotorszelep
T.BOLLVíztartály-termosztát
POS használativízidőprogramozója
S.BOLL.Tárolótartály
PAFűtésnyomáskapcsolója(víz)
MOD Modulátor
CN1÷CN13 Csatlakozók
[SL] “L-N” - Priporoča se “L-N” polarizacija
Blu=Modra / Marrone=Rjava / Nero=Črna /
Rosso=Rdeča / Bianco=Bela / Viola=Vijolična /
Grigio=Siva/Arancio=Oranžna
A=24VMostičeknizkonapetostnegasobnegater-
mostata
B = Ventil plina
C = I/D elektroda
D = Varovalka 3.15A F
MP Krmilna kartica
P1 Potenciometer za izbiro off – poletje – zima – re-
set / temperatura ogrevanja
P2 Potenciometer izbire nastavitve tople sanitarne
vode
P3 Potenciometer izbire krivulje toplotne regulacije
JP1Mostičekzavklopnastavitvenihgumbov
JP2Mostiček za izbrisčasovnikaogrevanja in po-
mnilnika maksimalne porabe toka ogrevanja med
umerjanjem
JP3MostičekizbireMETAN-UNP
JP4 Izbirno stikalo absolutnih termostatov sanitarne
vode
JP5Mostičekzaizbirodelovanjasamozaogrevanje
s pripravo za zunanji kotel s termostatom ali tipalom
JP6 Ni uporabljen
F1 Varovalka 2A T
FZunanjavarovalka3.15AF
M3 Spojni blok za zunanjo povezavo 230V
M4 Spojni blok za zunanje povezave: tipalo grelni-
ka/termostatagrelnikaaličasovniprogramatorsani-
tarnevode(POS)
T.A. Sobni termostat
E.A./R.Elektrodazavžig/zaznavanje
TR1Transformatorzadaljinskivžig
V Ventilator
P.F.Tlačniventildimnihplinov
S.R.Tipalo(NTC)temperatureprimarnegakrogotoka
T.L. Mejni termostat
OPE Krmilnik plinskega ventila
PČrpalka
3V Servomotor tripotnega ventila
T.BOLL Termostat bojlerja
POS Aličasovniprogramatortoplesanitarnevode
S.BOLL. Hranilnik
PATlačniventilogrevanja(voda)
MOD Modulator
CN1÷CN13 Spojniki
[RO] Se recomandă polarizarea "L-N”
Albastru=Blue / Maro=Brown / Negru=Black /
Roşu=Red / Alb=White / Mov=Violet / Gri=Grey /
Portocaliu=Orange
A=Jumpertermostatdeambientdejoasătensiune24V
B=Vanăgaz
C = Electrod I/D
D=Siguranţăfuzibilă3.15AF
MPPlacădecomandă
P1Potenţometruselectareoff-vară-iarnă–reset/
temperaturăîncălzire
P2PotenţometruselectarepunctsetatcircuitACM
P3Potenţometruselectarecurbetermoreglare
JP1 Jumper abilitare butoane pentru calibrare
JP2Jumperresetaretimerîncălzireşimemorizare
valoareamaximăelectricălaîncălzireînmomentul
calibrării
JP3 Jumper selectare MTN - GPL
JP4 Selector termostat absolut circuit ACM
JP5Jumperselectarefuncţionaredoarîncălzirecupre-
dispoziţiepentruboilerexterncutermostatsausondă
JP6 neutilizat
F1Siguranţăfuzibilă2AT
FSiguranţăfuzibilăexternă3.15AF
M3Bornăpentruconexiuniexterne:230V
M4 Morsettiera per collegamenti esterni: sonda
bollitore/termostato bollitore o programmatore orario
sanitario(POS)
T.A. Termostat de ambient
E.A./R.Electrodaprindere/relevareacără
TR1Transformatordeaprindereladistanţă
V Ventilator
P.F. Presostat fum
S.R.Sondă(NTC)temperaturăcircuitprincipal
T.L.Termostatlimită
OPEOperatorvanăgaz
PPompă
3VServomotorvanăcu3căi
T.BOLL Termostat boiler
POS programator orar ACM
S.BOLL.Sondăboiler
PAPresostatîncălzire(apă)
MOD Modulator
CN1÷CN13 Conectori
91
CIAO S C.S.I. - CIAO S R.S.I.
[EN] Circulator residual head
A= Capacity (l/h)
B= Head (m A.C)
Theresidualheadfortheheatingsystemisrep-
resented,accordingtocapacity,inthenextgraph.
Heatingsystempipingdimensioningmustbecar-
ried out bearing in mind the value of the available
residual head.
Bearinmindthattheboileroperatescorrectlyif
watercirculationintheheatexchangerissufcient.
To this aim, the boiler is equipped with an auto-
maticby-passthatadjustswatercapacityproperly
intheheatexchangerinanysystemconditions.
First speed
Second speed
Third speed
[F] Prévalence résiduelle du circulateur
A= Débit (l/h)
B= Prévalence (m C.A)
La prévalence résiduelle pour l'installation de
chauffage est représentée en fonction du débit
dans le graphique ci-contre.
Ledimensionnementdestuyauxdel'installation
de chauffage doit être effectué en considérant
la valeur de la prévalence résiduelle disponible.
Il faut prendre en compte que la chaudière fonc-
tionnecorrectements'ilyaunecirculationd'eau
sufsantedans l'échangeurde l'installationde
chauffage.
Danscebut,lachaudièreestéquipéed'unby-
pass automatique qui règle un débit d'eau correct
dans l'échangeur de chauffage, dans n'importe
quelle condition de l'installation.
First speed = première vitesse
Second speed = deuxième vitesse
Third speed = troisième vitesse
[ES] Altura de carga residual del circulador
A= Caudal (l/h)
B= Altura de carga (m C.A)
La altura de carga residual para la instalación
de calefacción está representada, en función del
caudal,porelgrácodeallado.
El tamaño de las tuberías de la instalación de
calefacción debe calcularse considerando el valor
de la altura de carga residual disponible.
Se debe tener presente que la caldera funciona
correctamente si el intercambiador de la calefac-
cióntienesucientecirculacióndeagua.
Porello,lacalderaestáequipadaconunby-pass
automático que regula el caudal correcto de agua
en el intercambiador de calefacción en cualquier
condición de la instalación.
First speed = primera velocidad
Second speed = segunda velocidad
Third speed = tercera velocidad
[PT] Prevalência residual do circulador
A= Vazão (l/h)
B= Prevalência (m C.A)
A prevalência residual para a instalação de aque-
cimento é representada, em função da vazão, pelo
grácoaolado.
O dimensionamento das tubagens da instalação
de aquecimento deve ser executado conside-
rando o valor da prevalência residual disponível.
Considere-se que a caldeira funciona correcta-
mente se no permutador do aquecimento existe
umacirculaçãodeáguasuciente.
Paraessanalidadeacaldeirapossuiumby-pass
automático que regula uma correcta vazão de
água no permutador de aquecimento em qualquer
condição da instalação.
First speed = primiera velocidade
Second speed = segunda velocidade
Third speed = terceira velocidade
[HU] Keringetőszivattyú maradék emelő
magassága
A= Hozam (áramlási mennyiség) (l/h)
B= Emelő magasság (m C.A)
Afűtőrendszermaradékemelőmagasságátaho-
zamfüggvényébenazoldalsógrakonszemlélteti.
Afűtőrendszer csöveinek améretezését aren-
delkezésreállómaradékemelőmagasságértékét
szemelőtttartvakellmeghatározni.
Vegyegyelembe,hogyakazánakkorműködik
megfelelően,haahűtőrendszerhőcserélőjébena
keringővízmennyiségeelegendő.
Éppezért,akazánelvanlátvaegyautomataby-pass
szeleppel, ami a rendszer bármiféle állapotában gon-
doskodikfűtőrendszer hőcserélőjébena megfelelő
vízhozam biztosításáról.
First speed = hamadik sebességfokozat
Second speed = második sebességfokozat
Thirdspeed=elsősebességfokozat
[RO] Prevalenţă reziduală circulator
A= debit (l/h)
B= prevalenţă (m C.A)
Prevalenţarezidualăîninstalaţiade încălzire
estereprezentată-înfuncţiededebit-îngracul
alăturat.
Dimensiuneatuburilor instalaţiei deîncălzire
trebuiesăealeasăavândînvederevaloareade
prevalenţărezidualădisponibilă.
Amintiţi-văcăinstalaţiafuncţioneazăcorectdacă
înschimbătoruldecăldurăcirculareaapeiseface
înmodcorect,ecient.
Înacest scop,cazanul estedotat cuun by-
passautomat carereglează debitulde apăîn
schimbătoruldecăldură,înoricesituaţies-araa
instalaţia.
First speed = a treia viteza
Second speed = a doua viteza
Third speed = prima viteza
[DE] Restförderhöhe der Umwälzvorrichtung
A= Durchsatz (l/h)
B= Förderhöhe (m C.A)
DieRestförderhöhefürdieHeizanlagewirdinAb-
hängigkeit vom Durchsatz in der nebenstehenden
Grakdargestellt.
Die Bemessung der Leitungen der Heizanlage
muss unter Berücksichtigung des Wertes der
verfügbarenRestförderhöheausgeführtwerden.
Man beachte, dass der Kessel richtig funktioniert,
wenn im Wärmetauscher der Heizung eine aus-
reichende Wasserzirkulation erfolgt.
Zudiesem Zweckist derKesselmit einem
automatischenBypass ausgestattet,der die
Einstellung des richtigen Wasserdurchsatzes
im Wärmetauscher der Heizung bei beliebigen
BedingungenderAnlageermöglicht.
First speed = erste Geschwindigkeit
Second speed = zweite Geschwindigkeit
Third speed = dritte Geschwindigkeit
[SL] Preostala črpalna višina črpalke
A= Zmogljivost (l/h)
B= Črpalna višina (m C.A)
Preostalačrpalnavišinaogrevalnegasistemaje
glede na zmogljivost predstavljena z diagramom
ob strani.
Dimenzioniranje cevi ogrevalnega sistema se
mora izvesti z upoštevanjem vrednosti preostale
črpalnevišine,kijenavoljo.Upoštevajte,dakotel
delujepravilno,čejevtoplotnemizmenjevalniku
kotla zadosten pretok vode.
Zata namenjekotel opremljensa samodejnim
obtočnimvodom,kiposkrbizareguliranjepravilnega
pretoka vode v toplotnem izmenjevalniku ogrevanja
ne glede na stanje sistema.
Firstspeed=prvárýchlosť
Secondspeed=druhárýchlosť
Thirdspeed=tretiarýchlosť
PORTATA (l/h)
PREVALENZA RESIDUA (mbar)
PRIMA VELOCITÀ
SECONDA VELOCITÀ
TERZA VELOCITÀ
A
B
1st speed
2nd speed
3rd speed
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

Beretta Ciao S 24 R.S.I. Installer And User Manual

Tip
Installer And User Manual
Acest manual este potrivit și pentru