Eldom Invest 30-150 Household Electric Water Heaters Instrucțiuni de utilizare

Tip
Instrucțiuni de utilizare
v221026
HOUSEHOLD ELECTRIC WATER HEATERS 30-150
designed for wall installation
MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE
EN
ÎNCĂLZITOARE DE APĂ ELECTRICE, DE UZ CASNIC 30-150
concepute pentru montarea pe pereţii încăperilor
INSTRUCŢIUNI DE MONTAJ, UTILIZARE ŞI ÎNTREŢINERE
RO
ВОДОНАГРЕВАТЕЛИ ЭЛЕКТРИЧЕСКИЕ, БЫТОВЫЕ 30-150
предназначенные для установки на стене помещения
ИНСТРУКЦИЯ ПО МОНТАЖУ, ПОЛЬЗОВАНИЮ И ОБСЛУЖИВАНИЮ
RU
S BOILERS ELEKTRISCH, VOOR HUISHOUDELIJK GEBRUIK, MET
EEN INHOUD 30-150 geschikt voor wandbevestiging
HANDLEIDING VOOR INSTALLATIE, GEBRUIK EN ONDERHOUD
NL
ELEKTRO-WARMWASSERSPEICHER FÜR DEN HAUSGEBRAUCH 30-150
wandhängend
MONTAGE-, BETRIEBS- UND WARTUNGSANLEITUNG
DE
CHAUFFE-EAUX ELECTRIQUES MENAGERS 30-150
destinés à monter sur le mur de la chambre
GUIDE D’INSTALLATION, UTILISATION ET ENTRETIEN
FR
NGROHES UJI ELEKTRIK 30-150L
Dizajnuar për montim në muri
MANUALI PËR INSTALIM, OPERACIONET DHE MIRËMBAJTJA
AL
SCALDABAGNI ELETTRICI, PER FABBISOGNO DOMESTICO, 30-150
Destinati per installazione a parete del locale
ISTRUZIONI DI INSTALLAZIONE, USO E SERVIZIO DI ASSISTENZA
IT
8
41
12
82
53
24
94
65
TERMOACUMULADORES ELÉTRICOS PARA USO DOMÉSTICO, 30-150
destinam-se para montagem à parede do compartimento
MANUAL DE INSTRUÇÕES DE MONTAGEM, USO E ASSISTÊNCIA TÉCNICA
PT
56
PODGRZEWACZE WODY ELEKTRYCZNE I UŻYTKOWE, 30-150
Przeznaczone do instalacji na ścianie pomieszczenia
INSTRUKCJA MONTAŻU, UŻYTKOWANIA I KONSERWACJI
PL
37
EЛЕКТРИЧНИ БОЈЛЕРИ ЗА ДОМАШНА УПОТРЕБА 30-150
Дизајнирани за инсталирање на ѕид
ПРИРАЧНИК ЗА ИНСТАЛАЦИЈА, РАБОТА И ОДРЖУВАЊЕ
MK
18
1c 4
1
3
5
8
2
1d
150l
240
Water inlet
Water outlet
Combined valve
Switch
Thermostat
Anode tester
Electronic control
Light indicator
EN DE
Wasseranschluss
Ablauf Wasser
Kombiniertes Ventil
Schalter
Thermostat
Anodentester
Elektronischen Steuereinheit
Leuchtanzeige
FR
Entrée de l'eau
Sortie de l'eau
Soupape combi
Bouton
Thermostat
Testeur anode
Unité de commande électroniques
Indicateur lumineux
Intrare apă
Ieşire apă
Supapă/valvă combinată
Cheie
Termostat
Tester anod
Bloc de comandă
Indicatorul luminos
RO
Вход вода
Выход вода
Комбинированный вентиль
Переключатель
Термостат
Анодный тестер
Электронным блоком управления
Световой индикатор
RUNL
1
2
3
4
5
6
7
8
Inlaat water
Uitlaat water
Gecombineerde klep
Schakelaar
Thermostaat
Anode tester
Digitaal bedieningspaneel
Licht indicator
Hyrja e ujit
Dalja e ujit
Ventili I kombinuar
Ndërprerësi
Termostati
Testeri I anodës
Kontrolli elektronik
Drita sinjalizuese
AL
1
2
3
4
5
6
7
8
IT
Ingresso, acqua fredda
Uscita, acqua calda
Valvola combinata
Chiave
Centralina di riscaldamento
Tester anodo
Blocco elettronico
Spia luminosa
PT
Entrada de água fria
Saída de água quente
Válvula combinada
Chave
Termorregulador
Prova de anódio
Unidade elétrica
Luz de sinalização
PL
Wlot, woda zimna
Wylot, woda ciepła
Zawór połączony
Przełącznik
Termostat
Tester anod
Elektroniczna kontrolująca
Lampa sygnalizacyjny
1003
MK
Влез на вода
Излез на вода
Комбиниран вентил
Прекинувач
Термостат
Тестер за Анода
Електронска Контрола
LED
3
/ Tabella / Tabela / Табла
/ Modello
Gruppo di capacità / Unidade de volume
Grupa pojemnościowa /
/ Dimensioni / Dimensões
Gruppo di capacità / Unidade de volume
Dimensioni /
Modelo / Модел
Modelo / Модел
Dimensões
/ Tabella / Tabela / Табла
Fig. / Afb. / Рис. / Rys. / Фиг.
Fig. / Afb. / Рис. / Rys.
Wymiary / Димензии
Wymiary
Димензии
/
(SV15044)
1420 / 1415
185 / 175
462 / 435
96 / 85
484 / 457
Група на Волумен
The values in the tables are only approximate. / Die in der Tabelle angegebenen Werte sind Richtwerte. / Les valeurs des tableau sont approximatives. / De waarden in de tabellen zijn ongeveer. / Valorile din
tabele sunt aproximative. / Значения в таблицах являются приблизительными. / Vlerat në tabela janë përafërsisht./ I valori riportati nella tabella sono approssimativi. / Os parâmetros nas tabelas têm valores
aproximativos. / Wartości w tablicach są orientacyjne. / Вредностите во табелите се приближни
EN
Water inlet
Water outlet
Heat exchanger I
Heat exchanger II
Thermostat coupling
DE
Wasseranschluss
Ablauf Wasser
Wärmetauscher I
Wärmetauscher II
Thermostatmuffe
FR
Entrée de l'eau
Sortie de l'eau
Échangeur de chaleur I
Échangeur de chaleur II
Douille de thermostat
7a K
B
4
RO RU
NL
1
2
8
9
10
Inlaat water
Uitlaat water
Warmtewisselaar I
Warmtewisselaar II
Mof van thermostaat
Intrare apă
Ieşire apă
Schimbător de căldură I
Schimbător de căldură II
Cuplung termostat
Вход вода
Выход вода
Теплообменник I
Теплообменник II
Муфта для термостата
AL
Hyrja e ujit
Dalja e ujit
Spiralja I
Spiralja II
Lidhja e termostatit
1
2
8
9
10
IT
Ingresso, acqua fredda
Uscita, acqua calda
Scambiatore di calore I
Scambiatore di calore II
Boccola per termostato
PT
Entrada, água fria
Saída, água quente
Permutador de calor I
Permutador de calor II
Acoplamento de termóstato
PL
Wlot, woda zimna
Wylot, woda ciepły
Wymiennik ciepła I
Wymiennik ciepła II
Mufa termostatu
MK
Влез на вода
Излез на вода
Изменувач на топлина I
Разменувач на топлина II
Муф за термостат
I - Model / Modell / Modиle / Model / Model / Модель /
Modeli / Modello / МоделModelo /
II - Volume group / Volumengruppe / Volume /
Capaciteitsgroep / Grup volumetric / Объемная
группа / Grupi I vëllimit / Gruppo di capacità /
Unidade de volume / Grupa pojemnościowa / Група
на волумен
III - Fig. / Afb. / Фиг. / Figura nr. / Rys. / Фиг.
IV - Coil-pipes surface / Flдche der Heizschlangen /
Surface des йchangeurs / Oppervlakte van de
serpentines / Suprafaţa serpentinelor / Площадь
змеевиков / Siperfaqja e gypit spiral / Superficie
delle serpentine / / Superfície das serpentinas
Powierzchnia wężownic / Powierzchnia wężownicy /
Должина на изменувачот на топлина
V - Dimensions / Abmessungen / Dimensions /
Afmetingen / Dimensiuni / Размеры / Dimensionet /
Dimensioni / / Wymiary / ДимензииDimensões
/ Tabella / Tabela
/ Tabella / Tabela
Emalia
440 440 440 640 440 440 640 430 640 640 450 350 350 440 500
200
5
The values in the tables are only approximate. / Die in der Tabelle angegebenen Werte sind Richtwerte. / Les valeurs des tableau sont approximatives. / De waarden in de tabellen zijn ongeveer. / Valorile din
tabele sunt aproximative. / Значения в таблицах являются приблизительными. / Vlerat në tabela janë përafërsisht./ I valori riportati nella tabella sono approssimativi. / Os parâmetros nas tabelas têm valores
aproximativos. / Wartości w tablicach są orientacyjne. / Вредностите во табелите се приближни
8 9
ANODE
T E S T E R
( ) – Option
Thermal cut-out
Thermostat
Rocker switch
Heater
Anode
Anode tester
Light indicator
1
2
3
4
5
6
7
Interrupteur thermique
Thermostat
Bouton
Thermostat
Anode
Testeur anode
Indicateur lumineux
Temperatuurbegrenzer
Thermostaat
Schakelaar
Verwarmingsunit
Anode
Anode tester
Licht indicator
Termo-întrerupător
Termostat
Cheie
Încălzitor
Anod
Tester anod
Indicatorul luminos
Термовыключатель
Термостат
Выключатель
Нагреватель
Анод
Анодный тестер
Световой индикатор
EN FR
RO RUNL
1
3
8
2
5
6 4 7
ENfor water pressure in the mains above 0,5 MPa
DEbei Wasserleitungsdruck ab 0,5 MPa
FRlorsque la pression de l'eau dans le conduit
passe au-dessus de 0,5 MPa
NLwanneer de waterdruk van de waterleiding
meer dan 0,5 MPa is
ROla presiune în conducta de apă de peste 0.5 MPa
RUпри давлении воды в водопроводе свыше 0,5 MPa
AL – Për shtypjen e ujit më te madhe se 0.5 MPa
IT – A pressione all’interno della condotta idrica
superiore allo 0,5 MPa
PT – Com pressão no condutor de água superior a 0.5 MPa
PL Przy ciśnieniu podgrzewacza wody powyżej 0,5 MPa
МК за притисок на водата во мрежата над 0,5 MPa
10
230 V~
L
N
1 2 34
65
1 2 3
6
230 V~
L
N
L(A1) L(A2)
N(B1) N(B2)
5
11 4
L(A1) L(A2)
N(B1) N(B2)
230 V~
L
N
LL
N N
1 2
74
3
(B1) (B2)
(A1) (A2)
12
Water heater
Water inlet
Water outlet
Stop cock
Combined valve
Reducing valve
Cold water
Hot water
EN DE
Warmwasserspeicher
Wasseranschluss
Ablauf Wasser
Sperrhahn
kombiniertes Ventil
Reduzierventil
Kaltwasser
Warmwasser
FR
Chauffe-eau
Entrée de l'eau
Sortie de l'eau
Vanne d'arrêt
Soupape combinée
Soupape de réduction
Eau froide
Eau chaude
Wärmeauslöser
Thermostat
Schalter
Heizelement
Anode
Anodentester
Leuchtanzeige
DE
1
2
3
4
5
6
7
13
230 V~
L
N
12
34
5
L(A1) L(A2)
N(B1) N(B2)
1 2 3
230 V~
L
N
L(A1) L(A2)
N(B1) N(B2)
14 4
5
5
WVxxxyy(A)
WVxxxyyD(A)
722xxW(N)(D)(G);
SVxxxyyDG
SVxxxyy; SVxxxyyG
SVxxxyyD
Fig.
10
11
Models
12
13
14
6
RO RU
NL
Boiler
Inlaat water
Uitlaat water
Afsluiter
Gecombineerde klep
Ontlastklep
Koud water
Warm water
Încălzitor de apă
Intrare apă
Ieşire apă
Robinet de oprire
Supapă/valvă combinată
Reductor de presiune
Apă rece
Apă caldă
Водонагреватель
Вход вода
Выход вода
Запорный кран
Комбинированный вентиль
Редукционный вентиль
Холодная вода
Горячая вода
1
2
3
4
5
6
7
8
AL
Ngrohës i ujit
Hyrja e ujit
Dalja e ujit
Ndales rubinete
Ventili I kombinuar
Ventili reduktues
Uji I ftohtë
Uji I ngrohtë
Ndërprerës termik
Termostat
Ndërpreres
Nxemsi
Anoda
Testeri I anodës
Drita sinjalizuese
1
2
3
4
5
6
7
AL
1
2
3
4
5
6
7
8
IT
Scaldabagno
Ingresso acqua
Uscita acqua
Rubinetto di arresto
Valvola combinata
Valvola di riduzione
Acqua fredda
Acqua calda
Interruttore termico
Centralina di riscaldamento
Chiave
Cartuccia riscaldante
Anodo
Tester anodo
Spia luminosa
1
2
3
4
5
6
7
IT
PT
Termoacumulador
Entrada de água
Saída de água
Válvula de corte
Válvula combinada
Válvula de redução
Água fria
Água quente
Interruptor térmico
Termorregulador
Chave
Aquecedor
Anódio
Prova de anódio
Luz de sinalização
PT
PL
Podgrzewacz wody
Wlot wody
Wylot wody
Kurek zamykający
Zawór połączony
Zawór redukcyjny
Woda zimna
Woda ciepła
Wyłącznik termiczny
Termostat
Przełącznik
Podgrzewacz
Anoda
Tester anod
Lampa sygnalizacyjna
PL
МК
Бојлер
Влез на вода
Излез на вода
Сигурносен вентил
Комбиниран вентил
Редуциран вентил
Ладна вода
Топла вода
Термички прекин
Термостат
Клуч
Грејач
Анода
Тестер за Анода
Сијаличка / LED
1
2
3
4
5
6
7
МК
A
1
2
3
4
A
15
16
B
6
1
B
5 - 50х50х5
A
B
7
1
2
3
4
A
EN Remark:
џPos. 1, 5 and 6 are welded.
џThe premise floor and
ceiling are made of
reinforced concrete.
FR Remarques:
џLes positions 1, 5 et 6 sont
soudées.
џLe plancher et le plafond de
la salle sont en béton armé.
NL Opmerkingen:
џDe posities 1, 5 en 6 zijn
gelast.
џDe vloer en het plafond van
de kamer zijn van
gewapend beton.
RO en iuni:M ţ
џPoziţiile 1, 5 şi 6 sunt
sudate.
џPodeaua şi tavanul
încăperii sunt din beton
armat.
DE Anmerkungen:
џPositionen 1, 5 und 6 sind
geschweißt.
џRaumdecke und -boden
aus Stahlbeton.
RU Примечания:
џПозиции 1, 5 и 6 сварные.
џПол и потолок
помещения из
железобетона.
1
2
3
4
5
6
7
EN DE FR
1
2
3
4
5
6
7
NL RO RU
Plate 4х60х360
Appliance plate
Bolt (stud) М10
Nut
Column (bracket)
Plate 4х100х100
Anchors for concrete
Platte 4х60х360
Platte des Geräts
Bolzen (Stiftschraube) М10
Mutter
Säule (Winkel 50х50х5)
Platte 4х100х100
Betondübel
Plaque 4х60х360
Tenon pour le dispositif
Boulon (tenon) М10
Écrou
Colonne (support 50х50х5)
Plaque 4х100х100
Chevilles d'ancrage pour le béton
Plaat 4х60х360
Plaat van het toestel
Bout (tapeind) М10
Moer
Kolom (profiel)
Plaat 4х100х100
Deuvels voor beton
Placă 4х60х360
Placa aparatului
Bolţ (ştift) М10
Piuliţă
Coloană (cot)
Placă 4х100х100
Ancoră pentru beton
Планка 4х60х360
Планка прибора
Болт (шпилька) М10
Гайка
Колонна (винкель)
Планка 4х100х100
Дюбель по бетону
Wall
Plate
Stud
Nut
Wand
Platte
Stiftschraube
Mutter
Perete
Placă
Ştift
Piuliţă
1
2
3
4
EN DE
Стена
Планка
Шпилька
Гайка
FR
1
2
3
4
NL RO RU
Mur
Plaque
Tenon
Écrou
Wand
Plaat
Tapeind
Moer
7
Muri
Tabela
Buloni
Dado
AL
AL Vërejtje:
џPoz. 1, 5, dhe 6 janë të
salduara
џBaza dhe tavani janë bërë
prej betoni të armuar.
AL
Pllaka 4х60х360
Tabela e pajisjeve
Buloni M10
Dado
Kolonat
Pllaka 4х100х100
Ankerat për beton
Parete
Piastra
Vite prigioniera
Rondella
IT
IT Osservazioni:
џPosizioni 1, 5 e 6 sono
saldate.
џIl pavimento e il soffitto del
locale sono in calcestruzzo
armato.
IT
Piastra 4х60х360
Piastra dell’apparecchio
Bullone (vite prigioniera) М10
Rondella
Colonna (profilo a L)
Piastra 4х100х100
Tassello per calcestruzzo
Wall
Placa
Espargos
Nut
PT
PT Notas:
џPosições 1, 5 e 6 - soldadas.
џO piso e o teto das instalações
são feitos de concreto reforçado
com aço.
Placa 4х60х360
Placa da equipe
Parafuso (prisioneiro) M10
Nut
Suporte (ferro perfilado)
4х100х100 prato
Concreto Armado Tarugo
PT
PL Uwagi:
џPozycje 1, 5 i 6
spawane.
џPodłoga i sufit
pomieszczenia są ze
wzmocnionego betonu.
Płyta 4х60х360
Płyta urządzeniaа
Śruba (kołek) М10
Nakrętka
Kolumna (uchwyt)
Płyta 4х100х100
Kołek do betonu
PL
PL
Ściana
Płyta
Kołek
Nakrętka
Стена
Планка
Шпилка
Гайка
MK
MK Забележки:
џПозиции 1, 5 и 6 са
заварени.
џПодът и таванът на
помещението са от
стоманобетон.
Планка 4х60х360
Планка на уреда
Болт (шпилка) М10
Гайка
Колона (винкел)
Планка 4х100х100
Дюбел за бетон
MK
WARNING! Before installation and operation with the appliance, read carefully the present manual!
KEY REQUIREMENTS FOR SAFETY
Before starting the installation of your appliance and its operation it
is compulsory to read carefully the text of the instructions booklet.
It is designed to familiarize you with the unit, with the rules for its
proper and safe use and the minimum activities necessary to
maintain and service it. Furthermore, you will need to provide this
guide for use by qualified persons who will install and repair the
unit in case of failure. Installation and commissioning of the unit is
not a warranty obligation of the seller and/or manufacturer.
Keep this guide in a suitable place for future reference.
Compliance with the rules helps for safety use of the appliance and
is one of the warranty terms and conditions.
ATTENTION! Installation of the water heater and connection to the water main system
should be performed only by qualified persons in accordance with the instructions in
present manual and local regulations in force. Installation of safety and other components
provided by the manufacturer is COMPULSORY!
ATTENTION! Connection of the water heater to the water main system should be
performed only by qualified persons in accordance with the instructions in present manual
and local regulations in force. The appliance should be properly connected to the current-
carrying wires and the protection grid! Do not connect the appliance to the electrical
installation before filling its water tank up with water! Failure to comply shall make the
appliance dangerous and in such state its use is strictly forbidden!
ATTENTION! Connecting the tank with integrated heat exchangers to a local heating system
(solar and/or other water heating systems using water or water solution as coolant) must be
carried out by qualified and competent persons in accordance with their design. The way of use
of such water heater when heating the water in its tank from an alternative electric coolant, as
well as compliance with safety measures must be carried out as described in the
supplementary instructions, regulations and requirements for use, servicing and maintenance.
Such additional instruction booklet is provided by the company responsible for the design and
installation works for connecting the tank to alternative heating sources.
WARNING! When using the appliance there is a risk of hot water scalding!
WARNING! Do not touch the appliance and its control panel with wet hands or if you are
barefoot or standing on a wet spot!
WARNING! This appliance may be used by children of age over 3 years old and persons with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, where
they are under supervision or instructed about the safe use of the appliance and understand
the dangers. Children must not be allowed to play with the unit! It is absolutely forbidden that
children undertake cleaning or servicing of this appliance! Children aged from 3 to 8 years are
only allowed to operate the tap connected to the water heater.
8
Dear clients, thank you for choosing device from ELDOMINVЕST LTD.- Bulgaria!
It will be trustworthy helper in your household for many years because in its production we have
combined high quality materials and innovative technologies.
To be sure of its hopeful and trouble-free operation, please read the installation and operating
instructions carefully.
EN EN
EN
ENVIRONMENTAL PROTECTION
This appliance is marked according the REGULATION concerning waste
electric and electronic equipment (WEEE). By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences
for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product.
The symbol on the product, or on the accompanying documents
indicates that this appliance may not be treated as household waste.
Instead it should be handed over to the applicable collection point for the
recycling of electrical and electronic equipment. Disposal must be carried
out in accordance with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of
this product, please contact your local city office, your household waste
disposal service or the shop where you purchased the product.
TECHNICAL DESCRIPTION
The water heater is intended for domestic purposes in households, and can
provide hot water from the common water main system simultaneously for a
few consumers kitchen, bathroom and etc.
The heated water should be correspond to the normative documents for
domestic water and, in particular: its chlorides composition should be less
than 250 mg/l and its electric conductivity should be more than 100 µS/cm,
while its pH within the limits of 6.5-8 for the water heaters with enameled
water tanks, and electric conductivity less than 200 µS/cm for the water
heaters with chrome-nickel steel water tanks. The water pressure in the
water supply system should be higher than 0.1 MPa and lower than 0.5
MPa. If the water pressure is higher than 0.5 MPa - please refer to the
instructions in the section for connection to the water supply network.
Special water heater models are in production (for regions where local
regulations require) with design to work in plumbing pressure up to 1 MPa.
The appliances water containers (water tanks) are properly protected
against corrosion by using high quality enameled coating, or are made of
high-range alloy chrome-nickel (corrosion resistant) steel. Water tanks with
enameled coating are equipped with built-in anodes made of special alloy
providing additional protection.
The outer casing of the appliances is made of epoxy-polymer coverage and
the heat insulation is made of CFC-free polyurethane foam.
Schematic views of the basic models with their modifications are shown in
Fig. 1-7, and technical specifications – in Tables 1, 1a, 2 and 2a. All figures
and tables are located at the beginning of this booklet.
The water heater models are marked with letters and digits as follow:
џThe first two letters and the following five digits indicate the device
base model.
џW/S the devices are designed for premise wall mounting.
џVthe water heater can be installed only in a vertical position.
џH the water heater can be installed only in a horizontal position.
џUthe water heater is with a universal mounting - can be installed in
a vertical or in a horizontal position.
џxxx – the first three digits after the letters „V“, „H“ or „U“, are code for
the water tank capacity range of the water heater.
џyy the next two digits are code of the device diameter.
џ„А“ – in the enameled water tank is built-in an anode tester indicating
the level of corrosion protection and anode wear, Fig. 1а, pos. 6
џIthe water tank of the appliance is made of chrome-nickel steel
alloy.
џS“, S2“, S21and „Т“ in the water heater are built-in one or two heat
exchangers for water heating from an alternative heat source (local
water heating, solar collector and any other similar sources), Fig. 4 for
SandS2“, Fig. 5 for „S21and Fig. 6 for „Т“. Water heaters with a
heat exchanger designed for horizontal installation, are shown in
Fig.7.
џL“ – the outlets of the heat exchanger and/or pipes for cold and hot
water of some vertical and horizontal water heaters are located on the
left side of the wall-mounted unit.
џR“ – the outlets of the heat exchanger and/or pipes for cold and hot
water of some vertical and horizontal water heaters are located on the
right side of the wall-mounted unit.
џBthe outlets of cold/hot water pipes of horizontal water heaters are
located below of the wall-mounted unit.
џD“, Cwithin the water heaters are built-in up to two electric heaters
located in special tubes on the water tank flange. It improves the
appliance safety of the device while increasing corrosion resistance.
"D" - with tubular metal heating element, to 1,6 kW for units with a
capacity up to 50 l (volume groups 30 and 50), up to 2 kW for units with
a capacity of up to 100 l (vol. groups 80 and 100) and up to 2,2 kW for
all others. "C" - with ceramic heating element, 1,5 kW for units in
volume group 50, and up to 2,2 kW for the remaining.
џ„Е“, „Еxy the water heater is equipped with electronic control unit for
the heater or for water heaters with heat exchangers - for the heater
and the devices for coolant flow control, Fig. 1b. These appliances are
accompanied by additional instructions describing how to use the
digital control unit.
џThe units with model numbers 722xxW(WN;WG;WNG;
WD;WND)/SVxxxyy have a reshaped design of the lower cover and
control, Fig. 1+1c/1+1d.
The hot and cold water pipes are marked with colored pointers, respectively
red and blue.
The water heater power (excluding those with letters "D" and "C") is 1,5 kW
for the units in volume group 30, up to 2 kW for the units in group 50 and 3 kW
for the rest.
The exact and complete model number, nominal operating parameters and
serial number of purchased water heater are marked on manufacturer plate
affixed on its body.
Water heaters for vertical installation. These models of heaters are
designed for mounting only in a vertical position with cold and hot water
pipes downward, Fig. 1 Fig. 4-6.
Water heaters for horizontal installation. These models of heaters are
designed for mounting only in a horizontal position in accordance with the
schema designed for each model number, Fig. 2 Fig. 3 Fig. 7
Water heaters for universal installation. These models water heaters are
designed for optional vertical (Fig. 1), or horizontal installation (Fig. 2).
WARNING! When the water heater with universal installation is mounted
in a horizontal position IT IS MANDATORY that the pipes for hot and cold
water, and its electric control be on its left side, see Fig. 2. Failure to do so
will make the unit dangerous and the manufacturer and / or the trader
shall not assume any responsibility for occurrence of any adverse effects
and damages!
Water heaters with heat exchanger. The water heaters of these models
secure an energy efficient operation thanks to their built-in heat exchangers.
The heat exchanger(s) outlets locations and their basic installation
distances are shown on Fig. 4, 5, 6, 7 and Tables 2 and 2a. By using a heat
exchanger bigger quantities of water inside the water container can be
heated through an additional alternative energy source, i.e. local or central
heating system, solar collectors and other similar sources. For more
efficient heat exchanger use it is recommended to move the heat-transfer
liquid with a circulation pump. For heat-transfer liquid can be used water with
composition and index values within the levels laid down in the regulations
related to water or a dedicated aqueous solution which is not aggressive to
heat exchanger material. The heat-transfer liquid must be with temperature
not higher than 85 °С and in its circuit must be installed a control device set
at this temperature in order not to allow thermal cut-out of the electrical
heating element during normal operation. The pressure of the heat-transfer
liquid in the heat exchangers must not exceed the stated working pressure
of the heater.
WATER HEATER INSTALLATION ON THE WALL
OF THE PREMISE
The water heater can be installed only in normal fire safeguarded premises
and where temperature cannot fall under 0 °C. The availability of a siphon
on the installation for waste waters as during normal usage of the water
heater, water may leak from the safety valve aperture. At the same time the
siphon will facilitate the water tank maintenance, prevention and servicing
operations when water needs to be drained out of the water tank.
The type and nature of wall construction material, the appliance dimensions,
9
EN
the way of fixing it, the location of its fixing elements and tubes, its protection
against dripping water must be taken into account when choosing the proper
place for installation. The protection against dripping water is marked on the
appliance production plate with its serial number. The appliance must be
mounted where it is protected against water dispersion or water pouring
over. In order to reduce heat loss it is recommended to keep minimum
distance between the heater and the places where the hot water is used.
If you purchased a water heater with factory-fitted power cord with plug, the
unit cannot be installed in a wet premise! The location of the device must
comply with the requirements for the electric installation and its contact.
Refer to the electrical connection of this instruction.
It is obligatory that there are spaces provided between the appliance and the
surrounding walls and the ceiling of the premise, as follow:
џFor vertical water heaters at least 70 mm between the appliance and
the ceiling; at least 50 mm between the appliance and the side wall; at
least 350 mm below the appliance to facilitate servicing and possible
repair.
џFor horizontal water heaters at least 70 mm between the unit and the
ceiling; at least 70 mm between the side cover (outlets excluded) and
the wall; at least 350 mm between the electric part plastic cover and
the wall to facilitate the servicing and possible repair, and a sufficient
distance below the unit for installation of water connections and drain
the water from the tank.
џIn tanks with heat exchangers must be kept a distance from the coil
terminals side and the joints for additional thermostats necessary to
connect the additional control and safety units.
Water heater should be installed steadily on the wall of the premises. For this
purpose steel bolts (studs), tightly fixed in the wall, with diameter 10-12 mm
are used. The fixing elements should be secured against pulling aside the
wall they should be anchor or passage bolts (depending of the wall
construction material). It is recommended that the elements on which the
heater will be suspended are designed for three times greater loads than the
appliance total weight and located in the water therein. Installation of the
water heater on decorative walls (made of single bricks or of other light
materials) is strictly forbidden. On Fig. 1,2,3,7 and in the tables are shown
the distances between the bolts (studs) for mounting the units. Vertical water
heaters of 150 liters are equipped with special type of suspension plates and
correspondingly the distance between the bolts (studs) differs from that of
other models and modifications, please refer to Fig. 1.
WARNING! The bearing plates of horizontal water heaters must be
securely clamped to the premise wall. Under the bolts heads (nuts on
studs) must be placed support washers!
Given the greater weight for water heaters of 150 liters there are higher
requirements for fixing to the premise wall and to the wall itself:
џGiven the wall type, material and strength, in order to provide secure
attachment for vertical water heaters it is necessary to build an
additional structure or to take adequate measures to strengthen an
existing one. Samples of such constructions are shown on Fig. 15 for
reinforced concrete wall thick 25 cm and more, and on Fig. 16 - for
brick wall and others materials.
WARNING! Non observance of the requirements for fixing the water
heater on the wall may cause damages of the appliance, damages on
other appliances and the premises, where the device is located, as well
as corrosion of the casing or even more serious failures and damages. In
such cases eventual failures and damages are not a subject to
manufacturer and seller warranty liabilities and will be at the expense of
the party which has not observed the present manual instructions.
The water heater mounting to the premise wall must be completed only by a
specialist.
WATER HEATER CONNECTION TO THE WATER
SUPPLY NETWORK
The plumbing to which the water heater will be connected, as well as any other
elements included in it shall have to withstand sustained water temperatures
above 80°C and for short periods - above 100°C, as well as to pressure at least
twice high the appliance working pressure.
Upon connection of the water heater to the water supply grid, the arrows and
indication rings around the water heater pipes for hot and cold water must be
observed (inlet and outlet pipes). With an arrow towards the pipe and blue
color is marked the cold water pipe and an arrow starting from the pipe in red
color - the hot water pipe. Some appliances pipes are additionally marked
with badges. The pipes outlets are with threading 1/2". A schematic diagram
for water heater connection is shown on Fig 8. When the water heater works
at the water pipe tank pressure and that of the safety valve. In the event
where the conduit pressure is greater than 0,5 MPa it shall be required the
installation of reduce valve (pressure-reducing valve). Where local
regulations require use of additional devices that are not included with the
unit supply set and are not placed in the packaging, these must be
purchased and installed according to regulations.
The water heater is equipped with a combined non-return-safety valve. The
latter is factory-fitted on the cold water pipe or is located in the packaging of
the appliance. The combined non-return-safety valve located in the
packaging of the appliance MUST OBLIGATORY be mounted on the cold
water pipe. During that installation the arrow on its hull showing the direction
of water flow through the valve must be followed.
WARNING! The absence or improper installation of the combined valve
supplied with the product is grounds for voiding the product warranty.
WARNING! It is FORBIDDEN to install any kind of shut-off fittings
between the combined valve and the water heater! It is absolutely
forbidden to obstruct the lateral opening of the combined valve and/or to
block its lever!
Where the plumbing pipes are copper or of another metal, other than that of
the water tank, or where brass fasteners are used, to install on it is obligatory
the water tank inlet and outlet non-metallic couplings (dielectric fittings).
ATTENTION! For units with heat exchangers. Any additional tubular
outlets (excluding those of the serpentines) that will be connected with the
plumbing, and the holes for additional thermostats and / or
thermomanometer must be closed with a package insert or other suitable
for the purpose. The connections must be sealed for a water pressure of at
least 1.6 MPa.
It is recommended to set up a draining system for any dripping from the
combined valve side opening. The draining pipe must have a constant
downward slope and located in frost secure environment and its ends to be
constantly kept open to the atmosphere.
Once the water heater is connected to the water supply main, its water tank
should be filled up with water. It is carried out in the following order:
џOpen completely the turn-cock for hot water of the most distant mixing
tap.
џOpen the stop valve on pos. 4 from Fig. 8.
џWait for the air from the system to come out and over half a minute
from the fitting outlet to flow out a thick and strong water stream.
џClose the turn-cock for hot water of the mixing tap.
џlift the lever of the combined valve on pos. 5 from Fig. 8 and wait for
about 30-60 seconds until a thick and powerful stream of water runs
out from the valve side opening.
џLoose the lever of the combined valve.
WARNING! If no water is coming out of the opening of the combined
valve or the flow is weak (during normal water pressure), this should be
considered as a malfunction indicating that impurities from the plumbing
or caused by sewage connections have blocked the safety valve of the
combined valve.
IT IS FORBIDDEN to proceed with appliance electric connection before
eliminating the reason for malfunction!
WARNING! Failure to comply with the requirements for connection to
the water supply system may cause partial filling up of the water tank and
malfunction of the heating element, or when the combined valve is not
installed at all or has been improperly installed this may even cause
destruction of the water tank, the room and/or other damages to tangible
and intangible property. Such consequences are not within the scope of
manufacturer or seller warranty liabilities and shall be at the expense of
the party, which has not observed the present manual instructions.
WARNING! The combined reciprocating safety valve is one of the unit
safety components ensuring security for water heater users. It is
specifically FORBIDDEN to use the water heater with a defective or
removed/unmounted combined safety valve!
The water heater connection to the water supply system must be performed
only by qualified persons.
10
EN EN
Where necessary the safety valve may serve for draining the water out of the
water tank. It is carried out the following order:
џDisconnect the heater from the electrical power supply network with
the optional device and for greater security disconnect the fuse in the
heater phase circuit.
џCut the cold water access to the appliance - close the stop cock, pos. 4
from Fig. 8.
џOpen the hot water cock on the tap or disconnect the tank hot water
pipe (outlet pipe) connection.
џLift the lever of the combined valve 5 in Fig. 8 and wait until the water
stops flowing out of the valve opening.
These steps do not still secure the complete draining of the water out of the
tank. It is completed only by a qualified person because it requires complete
disconnection of the appliance electric circuit and dismantling the water tank
flange.
WARNING! IT IS STRICTLY PROHIBITED to turn on the heater power
while the water tank is partially or completely emptied of water! Do not
forget to fill the tank with water before putting it back into operation.
WARNING! The coolant circulation through the heat exchanger of a
water heater equipped with such device is PROHIBITED when the water
tank is partially or completely emptied of water.
WARNING! When draining the water out of the water tank all necessary
precautions must be taken to prevent damages from flowing out water.
CONNECTING THE HEAT EXCHANGER OF
WATER HEATER TO THE ALTERNATIVE HEAT
SOURCE CIRCUIT
The water heater with heat exchanger must be connected to the alternative
heat source in accordance with the special additional instructions provided
by the company responsible for the installation and connection of the heater
design. It is mandatory to install all supplied and/or recommended by this
company safety, control and coolant movement management devices.
WARNING! It is prohibited to fit stop valves on heat exchanger both ends
(inlet and outlet) simultaneously. In cases where the water heater heat
exchanger shall not be used and is not connected to the heat source
circuit, it must be filled with propylene glycol solution suitable for heating
systems.
Connecting the heat exchanger of the water heater to an alternative heat
source circuit must be completed only by qualified technicians in the field
from a company specializing in such services and in accordance with the
design.
WATER HEATER CONNECTION TO THE POWER
SUPPLY NETWORK
WARNING! Do not proceed to connect the water heater to the power
supply network unless you have made sure that its water tank is full with
water! Check!
The water heater is an appliance with protection degree against current
damages Class I, which requires its compulsory connection to the earthling
circuit of the power supply installation.
The water heaters models electric circuit schema are shown on Fig. 10-14.
The electric power supply of the water heater is 230 V~ and is performed by a
separate current circuit of insulated three-core supply cable with a cross-
2
section of each of the wires of 2,5 mm (phase, neutral and grounding).
Therefore if the in-wall cable is two-wire, a qualified electrician must add a
third, protective conductor with no interruption on its track from the
switchboard to the water heater. If the earthling conductor/wire has
intermediate connections, latter must be secured against loosening.
Otherwise the appliance shall not be correctly earthed and it shall reduce its
safety.
WARNING! IT IS COMPULSORY that in the electric circuit feeding the
heater is installed such a device which in the conditions of over voltage
category III provides full disconnection of all poles. The conductors
between the circuit and the device incoming electrical terminals must not
be interrupted by any circuit breaker or fuse. Should the water heater be
installed in premise with shower cubicle and/or bath the disconnecting
device must be located outside.
All the extremities of wires in the appliance circuit must be properly
connected to the main power switchboard and in the heater connection point
to the power supply grid. In the phase circuit it is obligatory to install an
electric fuse 10 А for water heater electric capacity up to 2 kW and 16 A for
electric capacity of 3 kW. The electric installation to which the heater will be
connected must be built in accordance with the requirements of the
applicable statutes and local regulations in force. Where the regulations in
force do not require that in the water heater circuit be installed an automatic
breaker against leakage of current (residual current protection device), we
recommend to install such a device.
The connection of the cables from the mains switchboard to the unit
terminals shall be carried out after carefully removing the plastic cover so
that the electrical wiring in the unit does not disengage. In accordance with
electric circuit schema glued on the cover connect the phase conductor of
the power wire to the terminal marked L (or A1 depending on the version),
the neutral wire to the terminal marked N (or B1) and the earthling - to the
security terminal (screw or stud) marked for safety grounding. The power
cord must be secured against displacement by using the cable clamp
located next to the cable entry in the plastic cover. After connecting and
attaching the power cable, put the plastic cover into place and secure it with
screws, taking care for free movement of cables, thermostat capillary tube
and the control switch.
If you have purchased water heater with pre-installed power cord with a plug,
the electric connection shall be carried out as the plug in put directly in a
functioning and grounded socket of the premise electric installation. The
socket should be on a separate, dedicated only for the water heater circuit
and located so as to be easily accessible after the unit installation. The
section of the electric installation wires in which the socket is placed must be
suitable for the water heater electric power consumption. On the phase line
must be installed a fuse (10 A for a capacity of 2 kW and 16 A for 3 kW). The
installation must be carried out in compliance with the regulations in force.
Taking out the power cord plug from its socket shuts down the water heater.
Faulty and / or inappropriate electric installation and / or socket are high-risk
conditions for accidents with damages to the product and possible damages
to the environment, objects and living species.
Once the appliance is connected to the power supply grid check its
functionality.
WARNING! Failure to comply with the requirements concerning
connection to the mains shall impede the appliance safety, in which it is
prohibited to use. Adverse effects occurring as a result of non-compliance
with requirements concerning the appliance electric connection are not
covered by the manufacturer and seller warranty liabilities and are at the
expense of the party violating the requirements of this instruction manual.
The water heater connection to the power supply and checks of its
functionality shall be performed only by specialists and are not manufacturer
or seller obligations and are not subject to warranty service.
HOW TO USE THE APPLIANCE
The water heater is switched on operative mode by switching the light key by
pressing its extremity marked „І”. With the knob you may adjust to desired
water temperature. Lighting of the key when in switched on position
indicates that the water heater is operating and water is heating, while when
the light is off it indicates that the water has reached adjusted temperature
and the heater is switched off. You may switch off the appliance by pressing
the end of the button of the glowing key marked "0". The water heater
complete disconnection from power supply takes place from the additional
disconnecting device.
For models marked with the letter "D" each key on the two-buttons light key
located on the control dashboard serves to switch on / off one of the heaters.
Thus you may use appliance half or full electric power depending on the
specific needs and desired time for water heating.
The models 722xxW(WN;WD;WND) (Fig. 1c) are provided with a switch,
and next to the thermostat knob – with a light indicator. The latter shows the
water heater operation. The 722xxWG(WNG) models do not have a switch
and are therefore switched on/off operating mode with the additional device
to disconnect the unit from power supply.
11
EN EN
The chart around the thermostat knob has a distinct sector marked ECO.
When the cursor of the knob is in the sector, the water is warmed to an
optimum temperature at which the heat losses of the device are reduced
and the reduced use of electric energy. At the same time, the warm water is
sufficient for normal households. When a need for a large amount of mixed
water is required the thermostat knob is rotated in the direction of travel
counterclockwise to its maximum position, to reach the higher temperature
of the water in the tank. We recommend to keep the knob in the sector ECO,
when the heater is left on for long periods without use of hot water and only to
store heated water.
The appliance built-in thermostat unit has antifreeze function. When the
thermostat knob is to the extreme left, at the scale beginning, the heater
shall switch on at ambient temperature around 8-10°C and shall switch off at
about 12-15°C. Thus in case of air temperature fall in the room, the water in
the tank will be protected from freezing. ATTENTION! This feature shall not
prevent the water in the room plumbing from freezing!
Switching on and off, set up and using water heaters equipped with
electronic control board takes place in accordance with the instructions and
requirements listed in the additional manual supplied with the appliance -
instruction how to connect and use an appliance with electronic control
board. For such appliances the additional instruction manual is an integral
part of the present installation and operation manual.
The temperature indicator installed on the appliance external coating
indicates the process of water heating. It is not a device for control
measurement and indicates only the approximate temperature and quantity
of hot water within the water tank.
WARNING! Do never switch the appliance if there is a chance that the
water in the water tank is frozen! This shall damage both heater and the
tank.
WARNING! This appliance may be used by children of age over eight
years old and persons with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, where they are under
supervision or instructed about the safe use of the appliance and
understand the dangers. Children must not be allowed to play with the
unit! It is absolutely forbidden that children undertake cleaning or
servicing of this appliance!
Within the combined valve is built a special valve which during water heater
normal operation allows the expanded during heating water not to leak
through the valve side hole, but to pass into cold water plumbing. The
quantity of this water is negligible and usually is with low temperature.
During normal operation of the water heater, as well as in present of
additional return valve, it is possible that through the valve side opening leak
some water drops. This should not be perceived as defect and the side hole
of combined valve should not be blocked because it shall cause destruction
of the tank. The built-in non-return valve in the combined valve prevents, in
case of cutting water supply, the water in the water tank to return to cold
water pipeline.
Using the built-in heater exchangers (for appliances equipped with) to heat
the water in the tank must take place in accordance with the instruction
provided for by the persons who carried out the design and installation of the
system for heating water from alternative electric sources. Compliance with
the instruction in such guides is mandatory.
When the appliance is used in areas with water rich in limestone it is possible
to hear some noises during water heating. The noise is due to the limestone
deposition on the heater and in the tank. The quantity of limestone contained
depends of the type of water and its heating temperature. When the latter is
higher than 60°С the quantity of separate limestone increases.
Accumulated limestone impedes the heater efficiency and may even cause
its failure, while increasing the time for water heating.
When using the appliance it is possible to hear some weak noise due to the
water flow through the pipelines and the appliance, as well as to the natural
process of expanding and heating.
When the heater is regularly used to heat water to a lower temperature, it is
recommended to turn the thermostat knob at least once monthly to its
maximum position, then to heat the water to maximum degrees and keep it
such at least for 24 hours. The purpose it to prevent bacteria growth.
ADDITIONAL CORROSION PROTECTION
Enameled water heater tanks. In each water heater with enameled tank is
installed additional corrosion protection. It consists of an anode of special
alloy operating only when the water tank is full. The anode is a consumable
(i.e. a device with normal wear during the appliance operation) and its
average operational life is up to 3 (three) years. This period depends much
of the type of operating the appliance and the characteristics of the heated
water. After the period of operational life, a manufacturer authorized
specialist or dealer service company must check the conditions of the
anode. Where necessary it should be replaced with new one. Compliance
with the inspection deadline and timely replacement of the anode is
important for the effective protection of the tank from corrosion. Both the
assessment and replacement of the anode are not subject of manufacturer
and seller warranty liabilities.
Water heater with enamel tank and anode tester. The availability of the
anode tester as control device is essential for the heater operation. Some
water heater modifications with traditional thermostat are equipped with
electromechanical anode tester (Fig. 9). It consists of a arrow-indicating
system with a scale and switch (button). The scale has two sections - red
and green. In tank normal operating condition the tester pointer is in the red
section - the tester is not switched on and the anode is working properly.
Checking the anode efficiency is carried out when the water is fully heated
(switched off thermostat, i.e. the key is not lit) by pressing for few seconds
the button on the tester. The arrow shall depart in the direction of the scale
green sector. The magnitude of the variation is strongly affected by the
parameters of the water and its temperature, as the boundary between the
two sectors correspond to the water average values. The anode efficiency
criterion is its arrow deflection. When at the time of pressing the tester
button, the arrow does not divert or is hold at the beginning of the red
section, you should contact the specialists at your nearest manufacturer or
vendor authorized service company. Their specialist shall review the tank
corrosion protection and repair, if necessary. In some water heaters
modifications the electronic control board indicates the anode efficiency and
degree of wear with periodic regular display blinking. With advanced wear
the size of lighted part decreases. More specifically the process is described
in the additional instruction manual concerning the electronic control board
functions. Once the lighted part of the display switches off completely you
may contact the closest service company to review and eventually replace
the anode.
Water tanks of high quality chrome-nickel steel. Corrosion protection and
guaranteed long life are secured by correct choice of steel, adequate design
and engineering construction during tank manufacture process.
SERVICE, PREVENTION, MAINTENANCE
In order to secure reliable operation of the water tank in areas with highly
calcareous water it is recommended to clean the limestone accumulated
within. This operation should take place at least once every two years, while in
areas with higher limestone content even more frequently. The depositions
on the enamel coating should not be removed otherwise than wiped with dry
cotton cloth and without using hard tools. Regular limestone removal and
cleaning is particularly important for appliance reliable operation. It is
recommended that during this maintenance operation you carry out a review
of the enameled tank anode condition. These services are not subject to
warranty coverage and must be performed only by qualified person.
WARNING! In order to ensure safe and trouble-free operation of the water
heater, the combined valve should be checked regularly for reduction of its
permeability. This is done by lifting the lever, and wait for 30-60 seconds
from the side opening the valve to flow thick and strong jet of water. This
operation must be carried out after connecting the heater to the plumbing
and when filling of the tank with water, in the process of using the heater
not less than once every two weeks, as well as eventually after stop and
start of water supply. When at full tank by opening the valve does not leak
or water flow is weak, there is a failure and probably the valve is clogged
by impurities in the sewage. Using water heater combined with a defective
valve is strictly prohibited. Switch off immediately the appliance from the
power supply and contact the nearest authorized by manufacturer service
company. Otherwise, it will cause damage to the water tank, and could
cause tangible and intangible damages in the room where the water
heater is located.
12
EN EN
When you are not certain about the temperature in the room where the water
heater is installed, i.e. that it may fall below 0°C, the water from the water
tank MUST be drained - please refer to section 'CONNECTION TO THE
WATER SUPPLY NETWORK’
The water heater outer shell and plastic parts can be cleaned using only a
slightly damp soft cotton cloth and never with invasive and/or abrasive
substances and preparations. Before cleaning the appliance, it MUST be
disconnected from the power supply with the additional disconnection device
or by unplugging the plug on the power cord. IT IS FORBIDDEN to clean the
appliance with steam generator. Particular attention should be paid to prevent
wetting of the appliance light switch on its control panel. The water heater may
be switched on in operation only after complete removal of moisture.
The rules for checking the corrosion protection and anode replacement
(please refer to previous section), as well as removal of the accumulated
limestone, must be strictly observed both during and after the appliance
warranty period.
During the appliance usage and maintenance do not damage the metal
plate with its technical data and serial number. Should you take it off, keep it
with the warranty form because it is the document serving to identify the
water heater.
FAILURES
When the heater does not heat the water, check if the external disconnecting
device is not switched off, if the lighting key is switched off and if the
thermostat knob is not turned to the lowest position.
If the power supply is in order, the lighting key is switched on and the
thermostat knob is turned to its highest position, but the water in the
appliance is still not warming (it is possible that the lighting key or the signal
lamp are lighted or not), using the external disconnecting device unplug the
heater and contact the nearest authorized service company.
In case when from the mixer at completely open tap for hot water there is no
leakage or water flow is weak, check if the filter at the mixer outlet is not
clogged, or whether the shut-off valve before the heater is not fully or
partially closed (4, Fig. 8), or if water supply is not stopped. If all listed above
causes are not the cause of failure, using the external disconnecting device
unplug the heater and contact the nearest authorized service company.
When the water heater is equipped with electronic control board, at the end
of the additional instruction manual are listed the error messages appearing
on the display in case of failure and what measures to take for each case. In
any other general case of failure, using the external disconnecting device
unplug the heater and contact the nearest authorized service company.
In case of failure of the power cord and/or plug for water heaters with such,
contact the nearest authorized by the manufacturer service company as the
cord with plug must be replaced by the manufacturer, its service agent, or a
person with similar qualifications in order to avoid danger.
WARRANTY, WARRANTY PERIOD AND
WARRANTY CONDITIONS
The warranty, warranty conditions, warranty period, warranty validity for
purchased appliance and service related manufacturer or vendor liabilities
during the appliance warranty period are listed in the appliance warranty
form. When buying the appliance the warranty form must be filled and
signed both by seller and buyer. Keep the warranty form in a secure place.
In all instances shall be in force the applicable laws, regulations and other
legislation dealing with the rights and obligations of consumer, seller and
manufacturer, and their relationships related to purchased water heater, its
installation, use, servicing and maintenance.
Warranty term is determined by seller and is in force only for the
geographical territory of the country.
Warranty is valid only if the appliance:
џIs installed according to the requirements for installation and
operation.
џIs used only as per designed purpose and in accordance with the
installation and operation manual.
Warranty consists of free of charge repair of all factory defects, which may
arise during the warranty term. Repair is performed by service specialists,
authorized by seller.
Warranty is not valid for damages, caused by:
џImproper transportation
џImproper storage
џImproper usage
џParameters of water, different from the admissible norms for quality of
drinking water, and particularly if the composition of chlorides is more
than 250 mg/l; the electrical conductivity is less than 100 μS/cm and
pH is outside of 6,5-8 for water heaters with enameled water tanks; the
electrical conductivity is more than 200 μS/cm for water heaters with
water tanks made of chrome-nickel steel.
џSupply voltage, different than the unit's rated voltage.
џDamages due to freezing of water.
џElemental perils, disasters and other force majeure circumstances.
џNon observance of the installation and operation manual.
џIn cases, when a non authorized person has tried to repair any kind of
a defect.
In the above cases the defect will be repaired against relative payment.
Warranty shall not apply to normal wear parts and components of the
device, parts that are being removed during normal use, lighting and signal
lamps and the like, changing the color of external surfaces, change of
shape, size and location of parts and components that are exposed to
impact and conditions that are not considered normal use.
Lost profits, tangible and intangible damages caused by temporary inability
to use the device during its prevention and repair shall not by covered by the
warranty.
COMPLIANCE WITH THE REQUIREMENTS OF THIS
INSTRUCTION MANUAL IS A PREREQUISITE FOR SAFE
OPERATION OF YOUR PURCHASED PRODUCT AND IS ONE OF
THE WARRANTY TERMS AND CONDITIONS.
IT IS ABSOLUTELY PROHIBITED TO THE USER OR ANY
AUTHORIZED BY HIM PERSON TO UNDERTAKE ANY CHANGES
IN THE PRODUCT DESIGN AND STRUCTURE. ANY FINDING OF
SUCH ACTIONS OR ATTEMPTS SHALL AUTOMATICALLY
RENDER VOID ALL WARRANTY LIABILITIES OF SELLER OR
PRODUCER.
IN CASE OF NECESSITY FOR SERVICE SEEK ONLY
MANUFACTURER AUTHORIZED SERVICE COMPANIES LISTED
IN THE ANNEXED FORM.
THE MANUFACTURER PRESERVED HIS RIGHT TO
STRUCTURAL CHANGES WITHOUT NOTICE WHERE SUCH
SHALL NOT AFFECT PRODUCT SAFETY.
13
EN EN
WARNUNG! Bitte lesen Sie diese Bedienungsanleitung vor Montage und Inbetriebnahme des
Warmwasserspeichers sorgfältig durch!
DE
SICHERHEIT, ALLGEMEINE WARNHINWEISE
Lesen Sie unbedingt die Anweisungen und Warnungen in diesem
Hand buch vor Mon tage und Inbe trieb nahme des
Warmwasserspeichers sorgfältig durch. Die hier angegebenen
Informationen dienen dazu, Sie mit dem Warmwasserspeicher,
mit den Regeln für seinen ordnungsgemäßen und sicheren
Gebrauch, mit den Mindestanforderungen für seine Wartung und
Instandhaltung vertraut zu machen. Überdies sind Sie verpflichtet,
dieses Handbuch den fachkundigen Personen, die das Gerät
installieren und eventuell reparieren werden, zur Verfügung zu
stellen. Die Installation des Warmwasserspeichers und die
Prüfung seiner Funktionstüchtigkeit liegen nicht in der
Gewährleistungspflicht des Händlers und/oder des Herstellers.
Diese Anleitung sollte grundsätzlich in der Nähe des Geräts für
späteres Nachschlagen aufbewahrt werden. Die Beachtung der
hier beschriebenen Regeln gehört zu den Maßnahmen für den
sicheren Gebrauch des Produkts und gilt als Teil der
Garantiebedingungen.
WICHTIG! Nur fachkundige Personen rfen den Warmwasserspeicher entsprechend der
Vorgaben in diesem Handbuch und der einschlägigen örtlichen Vorschriften installieren und
an die Wasserleitung anschließen. Die vom Hersteller bereitgestellten oder empfohlenen
Schutzeinrichtungen sowie alle anderen Baugruppen sind UNBEDINGT einzubauen!
WICHTIG! Nur fachkundige Personen dürfen den elektrischen Anschluss des
Warmwasserspeichers entsprechend der Vorgaben in diesem Handbuch und der
einschlägigen örtlichen Vorschriften ausführen. Der richtige Anschluss des Gerätes an die
stromführenden Leitungen und an den Schutzkreis ist besonders wichtig! Vor Anschluss an
das Stromversorgungsnetz ist der Warmwasserspeicher unbedingt mit Wasser zu befüllen!
Die Nichteinhaltung der Anforderungen r den elektrischen Anschluss beeinträchtigt die
Gerätesicherheit, sodass der Warmwasserspeicher nicht verwendet werden darf.
WICHTIG! Nur fachkundige Personen dürfen den Warmwasserspeicher an eingebaute
rmetauscher der rmeversorgung (Solaranlage und/oder andere Warmwasserspeicher,
die Wasser oder Wasserlösung als Wärmeträger verwenden) entsprechend dem von ihnen
ausgearbeiteten Projekt anschließen. Die Art der Verwendung eines derartigen
Warmwasserspeichers, bei dem die Warmwasserbereitung durch einen alternativen
rmeträger gesichert ist, wie auch die Einhaltung der Sicherheitsvorschriften, erfolgen nach
Maßgabe der in der zusätzlichen Bedienungs-, Gebrauchs- und Wartungsanleitung
beschriebenen Regeln und Anforderungen. Das Unternehmen, das die Projekt- und
Montageleistungen im Zusammenhang mit dem Anschluss des Warmwasserspeichers an
alternative rmequellen ausgeführt hatte, stellt diese zusätzliche Anleitung zur Verfügung.
WARNUNG! Bei der Verwendung des Gerätes besteht Verbrennungs- oder
Verbrühungsgefahr!
WARNUNG! Es ist streng verboten, das Gerät oder seine Steuerung barfuß oder mit nassen
nden zu berühren!
WARNUNG! Dieses Gerät darf von Personen (einschlilich Kindern ab 3 Jahre) mit
14
DE
Sehr geherte Kunden, wir danken Ihnen, dass Sie ein Gerät von ELDOMINVEST GmbHBulgarien,
gewählt haben !
Das Gerät wird lange Jahren in Ihrem Hauhalt dienen, da wir bei der Produktion hochwertige Materialien
und innovative Technologien kombinierten.
Um Sie in seiner Zuverlässigkeit sicher zu sein, lessen Sie bitte sorgfältig die Installations- und
Bedienungsanweisung durch.
eingeschränkten körperlichen oder geistigen
Fähigkeiten nur dann verwendet werden,
wenn diese Personen unter der Aufsicht einer
verantwortlichen Person stehen oder von
dieser Person in den Gebrauch des Geräts
eingewiesen wurden. Kinder müssen
beaufsichtigt werden, damit sie in keinem Fall
mit dem Gerät spielen. Es ist verboten, dass
Kinder das Gerät reinigen oder selbstständig
bedienen. Kinder im Alter von 3 bis 8 Jahren
dürfen nur den am Warmwasserbereiter
angeschlossenen Wasserhahn bedienen.
UMWELTSCHUTZ
Dieses Gerät ist entsprechend der Richtlinie für die Elektro- und Elektronik-
Altgeräte (WEEE) gekennzeichnet. Indem Sie dafür sorgen, das Gerät am
Ende seiner Lebensdauer bei einem geeigneten Entsorgungszentrum
abzugeben, tragen Sie zum Umweltschutz und zur Vermeidung von
negativen Einwirkungen auf die Umwelt und auf die menschliche
Gesundheit bei.
Dieses Symbol auf dem Gerät oder auf den dem Gerät beigefügten
Dokumenten weist darauf hin, dass das Gerät am Ende seiner Lebensdauer
nicht im normalen Hausmüll entsorgt werden darf. Es muss bei einem
Entsorgungszentrum mit speziellen Einrichtungen für elektrische oder
elektronische Geräte abgegeben werden. Der Endverbraucher muss bei
der Entsorgung die örtlichen Entsorgungsvorschriften beachten. Weitere
Informationen über die Behandlung, Verwertung und über das
Recyclingverfahren erhalten Sie bei Ihrer Stadtverwaltung, bei Ihrem
zuständigen Entsorgungszentrum oder bei dem Fachhändler, bei dem Sie
das Produkt gekauft haben.
TECHNISCHE DATEN
Dieser Warmwasserspeicher ist für den Hausgebrauch im Haushalt
vorgesehen, und kann warmes Wasser von dem allgemeinen
Wasserleitungsnetz für mehrere Verbraucher – in der Küche, in dem Bad etc.
- gleichzeitig sichern.
Das zur Erwärmung verwendete Wasser muss der Anforderungen in den
normativen Dokumenten für Brauchwasser entsprechen, insbesondere:
Chloridgehalt bis 250 mg/l; elektrische Leitfähigkeit ab 100 µS/cm, pH-Wert
6,5-8 für Warmwasserspeicher mit emailliertem Wasserbehälter; elektrische
Leitfähigkeit bis 200 µS/cm für Warmwasserspeicher mit Wasserbehälter
aus Chrom-Nickel-Stahl. Der Wasserdruck in der Wasserleitungsanlage soll
höher als 0,1 МРа und niedriger als 0,5 МРа sein. Lesen Sie die Hinweise in
dem Abschnitt „Anschluss an das Wasserleitungsnetz“. Wenn der Druck in
der Wasserleitungsanlage höher als 0,5 МРа ist siehe „Anschluss des
warmwasserspeichers an die wasserleitung“. Es werden auch Ausführungen
von Warmwasserspeichern hergestellt (für Regionen, in denen ein höherer
Wasserdruck in der Wasserleitungsanlage nach den einschlägigen örtlichen
Vorschriften notwendig ist), die für Wasserdruck in der Wasserleitungsanlage
bis 1 МРа ausgelegt sind.
Die Wasserbehälter dieser Geräte sind durch hochwertige
Emaillebeschichtung korrosionsgeschützt oder aus hochlegiertem Chrom-
Nickel-Stahl (korrosionsbeständig) hergestellt. Als zusätzlicher Schutz sind in
den Wasserbehältern mit Emaillebeschichtung auch Anoden aus spezieller
Legierung eingebaut.
Der Außenmantel der Stahlgeräte besteht aus Epoxidharz-Polymer-
Beschichtung, und die Wärmeisolierung besteht aus FCKW-freiem
Polyurethanschaum.
Eine schematische Darstellung der Grundmodelle und –ausführungen ist auf
Fig. 1-7 dargestellt, und die entsprechenden technischen Daten sind in den
Tabellen 1, 1a, 2 und 2a zu finden. Sämtliche Abbildungen und Tabellen
finden Sie am Anfang dieser Anleitung.
Die Modelle der Warmwasserspeicher und ihre Ausführungen werden mit
Buchstaben und Ziffern gekennzeichnet wie folgt:
џDie ersten zwei Buchstaben und die darauffolgenden fünf Ziffern
weisen auf das Basismodell des Gerätes hin.
џ„W“/Sdie Geräte sind zur wandhängenden Montage ausgelegt.
џ„V“ der Warmwasserspeicher kann nur vertikal installiert werden.
џ„H“ der Warmwasserspeicher kann nur horizontal installiert werden.
џ„U“ für universelle Montage ausgelegter Warmwasser-speicher,
horizontal oder vertikal.
џxxx die ersten drei Ziffern nach der Buchstabe „V“, „H“ oder U“,
Kennziffer des Volumens des Warmwasserspeichers.
џyy die nächsten zwei Ziffern, Kennziffer des Gerätedurch-messers.
џ„А“ – dieser Warmwasserspeicher ist mit emailliertem Wasserbehälter
mit eingebautem Anodentester ausgestattet - Anzeige für die Funktion
des Korrosionsschutzes und für den Verschleiß der Anode, Fig. 1A,
Pos. 6
џ„I“ –Wasserbehälter aus hochlegiertem Chrom-Nickel-Stahl.
џ„S“, „S2“, „S21“ und „Т“ der Wasserbehälter hat einen oder zwei
eingebaute Wärmetauscher zur Erwärmung von Wasser durch
alternative Wärmequelle (lokale Wasserheizung, Solaranlage etc.),
Fig. 4 für „S“ und „S2“, Fig. 5 für „S21“ und Fig. 6 für „Т“. Die für
horizontale Instalation vorgesehenen Warmwasserspeicher mit
Wärmetauscher sind auf Fig. 7 gezeigt.
џ„L“ – die Anschlüsse des Wärmetauschers und/oder die Anschlüsse
für Kalt- und Warmwasser bei manchen vertikalen und horizontalen
Warmwasserspeicher befinden sich auf der linken Seite des an der
Wand angebrachten Gerätes.
џ„R“ – die Anschlüsse des Wärmetauschers und/oder die Anschlüsse
für Kalt- und Warmwasser bei manchen vertikalen und horizontalen
Warmwasserspeicher befinden sich auf der rechten Seite des an der
Wand angebrachten Gerätes.
џ„B“ – die Anschlüsse für Kalt- und Warmwasser bei den horizontalen
Warmwasserspeichern befinden sich auf der unteren Seite des an der
Wand angebrachten Gerätes.
џ„D“, „C“ in den Warmwasserspeichern sind bis zu zwei elektrische
Heizelemente integriert, die sich in speziellen Flanschrohren des
Wasserbehälters befinden. Dadurch wird die Getesicherheit
verbessert und die Korrosion-sbeständgheit eröht.D
Rohrheizelement aus Metall, bis 1,6 kW – für die Geräte bis 50 l Inhalt
(Volumengruppen 30 und 50), bis 2 kW für die Geräte bis 100 l Inhalt
(Volumengruppen 80 und 100) und bis 2,2 kW für alle anderen. „C“ –
keramisches Heizelement, 1,5 kW für die Geräte der Voumengruppe
50 und bis 2.2 kW für alle anderen.
џ„Е“, „Еxy“ der Warmwasserspeicher ist mit einer elektronischen
Steuereinheit für das Heizelement bzw. bei Warmwasserspeicher mit
Wärmetauscher – mit Steuereinheit für das Heizelement und für die
Kontrollgeräte des Wärmeträgerflusses ausgestattet, Fig. 1b. Für
diese Geräte ist eine separate Bedienungsanleitung der
elektronischen Steuereinheit angelegt.
џD i e G e r ä te m it M od e l l nu mm er n 7 22 xx W( WN ; W G ;
WNG;WD;WND)/SVxxxyy haben ein unterschiedliches Design des
unteren Deckels und der Steuerung, Abb. 1+1c/1+1d.
Die Kalt- und Warmwasserrohre sind farblich gekennzeichnet jeweils blau
und rot.
Die elektrische Leistung der Warmwasserspeicher (ausgenommen die mit
Buchstaben „D“ und „C“ gekennzeichneten Warmwasser-speicher) beträgt
1,5 kW für die Geräte der Gruppe 30, bis 2 kW für die Geräte der Gruppe 50
und bis 3 kW für alle anderen Geräte.
Die genaue und vollständige Nummer des Modells, die angegebenen
Betriebsparameter und die Seriennummer des gekauften
Warmwasserspeichers entnehmen Sie dem angeklebten Typenschild.
Warm w assers peiche r f ü r v ertika l e I nstall ation. Die se
Warmwasserspeicher sind ausschließlich für die vertikale Installation
ausgelegt, die Kalt- und Warmwasserrohre sind nach unten gerichtet, siehe
Fig. 1, Fig. 4-6.
Warmwasserspeicher für horizontale Installation. Diese
15
DE DE
Warmwasserspeicher sind ausschließlich für die horizontale Installation,
gemäß dem ihrer Modellnummer entsprechendem Schema ausgelegt,
siehe Fig. 2, Fig. 3, Fig. 7
Warmwasserspeicher für universelle Installation. Diese
Warmwasserspeicher können entweder vertikal (Fig. 1) oder horizontal
(Fig. 2) installiert werden.
WARNUNG! Für die horizontale Installation eines zur universellen
Installation ausgelegten Warmwasserspeichers müssen die Kalt- und
Warmwasserrohre sowie die elektrische Einheit UNBEDINGT auf der
linken Seite sein, siehe Fig. 2. Die Nichteinhaltung dieser Anforderung
beeinträchtigt die Gerätesicherheit, und der Hersteller und/oder der
Händler haften nicht für die daraus entstandenen Folgen und Schäden!
Warmwasserspeicher mit Wärmetauscher. Diese Warmwasserspeicher
kennzeichnen sich durch Möglichkeit zur reduzierten Stromaufnahme
aufgrund des eingebauten Wärmestauschers. Die grundsätzliche
Anordnung der Anschlüsse des/der Wärmetauscher/s und die
einzuhaltenden Montageabstände sind auf Fig. 4, 5, 6, 7 und gezeigt und in
den Tabellen 2 und 2a angegeben. Dank des eingebauten Wärmetauschers
kann ein überwiegender Teil des Wassers im Wasserbehälter auch durch
eine zusätzliche, alternative Wärmequelle erhitzt werden so z.B. Lokal-
oder Zentralheizung, Solarkollektoren etc. Zur Erhöhung der Effizienz des
Wärmetauschers empfehlen wir, dass der Wärmeträger durch eine
Umwälzpumpe getrieben wird. Als Wärmeträger kommt Wasser zum
Einsatz, dessen Zusammensetzung und Kennwerte Abweichungen von
den zulässigen Normen aufweisen können, sofern die in den
Wasserrechtsvorschriften angegeben sind. Eine andere Möglichkeit bietet
die speziell für diesen Zweck vorbereitete Wasserlösung, die gegenüber
dem Stoff des Wärmetauschers nicht aggressiv ist. Die maximal zulässige
Temperatur des Wärmeträgers ist 85 ° С. An seinem Kreis soll ein
Steuergerät eingebaut werden, deren Temperatur und Einstellung eine
Betätigung des Wärmeauslösers des elektrischen Heizelements bei
Normalbetrieb des Geräts nicht erlaubt. Der Druck des Wärmeträgers in
den Wärmetauschern darf den angegebenen Betriebsdruck des
Warnwasserspeichers nicht überschreiten.
MONTAGE DES WARMWASSERSPEICHERS
WANDHÄNGEND
Der Warmwasserspeicher darf nur in einem Raum mit Brandschutz und
Raumtemperatur dauerhaft über 0 °С installiert werden.
Bei dem normalen Betrieb des Warmwasserspeichers treten kleine Mengen
Wasser aus dem Sicherheitsventil aus. Aus diesem Grund muss der Ablass
mit einem Abflussrohr verbunden werden. Dadurch werden auch die
Wartungs-, Instandhaltungs- und die Servicemaßnahmen bei dem
Warmwasserspeicher erleichtert, insbesondere für den Fall, dass das
Wasser aus dem Wasserbehälter abgelassen werden soll.
Bei der Wahl eines geeigneten Aufstellungsortes für den
Warmwasserspeicher ist folgendes zu berücksichtigen: Art und Material der
Wand, Abmessungen des Geräts, Befestigungsart, Anordnung der
Befestigungselemente für die Wandbefestigung, Anordnung der Rohre,
Schutzgrad gegen Wasserspritzer.
Der letztgenannte Parameter ist auf dem Typenschild angegeben. Das
Gerät soll an einem Ort installiert werden, an dem er nicht mit Wasser in
Kontakt kommt. Der Warmwasserspeicher sollte möglichst nah an der
Entnahmestelle angebracht werden, um Wärmeverluste durch die Leitung
zu begrenzen.
Ist der gekaufte Warmwasserspeicher mit einem Versorgungskabel mit
Netzstecker ausgestattet, so darf das Produkt nicht in einem feuchten
Raum installiert werden! Der Aufstellungsort muss mit den Anforderungen
für das Stromversorgungsnetz und für die Steckdose übereinstimmen.
Siehe den Abschnitt über den Elektroanschluss.
Folgende Mindestabstände zwischen dem Gerät und den benachbarten
Wänden sowie zu der Raumdecke sind unbedingt einzuhalten:
џBei vertikalen Warmwasserspeichern – mindestens 70 mm zwischen
dem Gerät und der Raumdecke; mindestens 50 mm zwischen dem
Gerät und der seitlichen Wand; mindestens 350 mm unter dem Gerät,
zur Erleichterung der Wartungs- und Reparaturmaßnahmen.
џBei horizontal wandhängenden Warmwasserspeichern – mindestens
70 mm zwischen dem Gerät und der Raumdecke; mindestens 70 mm
zwischen der seitlichen Abdeckung (ohne Anschlüsse) und der Wand;
mindestens 350 mm zwischen der Kunststoffabdeckung mit dem
elektrischen Teil und der Wand, zur Erleichterung der Wartungs- und
Reparaturmaßnahmen. Darüber hinaus ist ausreichend Abstand
unter dem Gerät, wenn die Rohre sich auf der Unterseite befinden, für
die Montage der Wasseranschlüsse und zum Ablassen des Wassers
aus dem Wasserbehälter vorzusehen.
џBei den Warmwasserspeichern mit Wärmetauschern ist so viel
Abstand von der Anschlussseite der Heizschlangen und der Muffen
für ihre zusätzlichen Thermostate zu lassen, dass der Anschluss der
zusätzlichen Kontroll- und Steuergeräte problemlos erfolgen kann.
Der Warmwasserspeicher soll an einer Wand fest angebracht werden.
Dazu Stahlbolzen (Stiftschrauben) mit 10-12 mm Durchmesser verwenden,
die an der Wand befestigt sind. Die Befestigungselemente sind gegen
Anziehen aus der Wand zu sichern verwenden Sie Ankerbolzen oder
Durchgangsbolzen (je nach Beschaffung der Wand). Die
Befestigungselemente, auf den der Warmwasserspeicher aufgehängt wird,
müssen für das dreifache Gewicht des mit Wasser gefüllten
Warmwasserspeichers ausgelegt sein. Es ist verboten, den
Warmwasserspeicher an dekorativen Wänden (aus einzelnen Ziegeln oder
aus leichten Baustoffen) zu montieren. Die Abstände der Bolzen
(Stiftschrauben) zum Aufhängen der Geräte sind auf Fig. 1, 2, 3, 7 und in
den Tabellen angegeben. Die vertikalen Warmwasserspeicher der Gruppen
150 sind mit anderem Plattentyp für die Aufhängung ausgestattet, so dass
sich der Abstand zwischen den Bolzen (Stiftschrauben) sich von den
anderen Modellen und Ausführungen unterscheidet, Fig. 1.
WARNUNG! Die Tragbügel der horizontalen Warmwasserspeicher
müssen fest an die Wand des Raums befestigt sein. Unter die
Schraubenköpfe (Muttern der Stiftschrauben) sind Unterlegscheiben
anzubringen!
An die Warmwasserspeicher der Gruppen 150 werden, in Anbetracht ihres
größeren Gewichts, höhere Anforderungen in Bezug auf die Befestigung an
die Wand des Raums und an die Wand gestellt:
џAngesichts der Art, des Materials und der Festigkeit der Wand, ist für die
sichere Befestigung der vertikalen Warmwasserspeicher auch eine
zutzliche Konstruktion auszuführen oder es sind passende
Befestigungsmaßnahmen zu ergreifen. Beispielhafte Konstruktionen
sind auf Fig. 15 – für 25 cm und mehr dicke Stahlbetonwand, und auf
Fig. 16 für Ziegelwand und Wand aus sonstigen Baustoffen gezeigt.
WARNUNG! Die Nichteinhaltung der Anforderungen hinsichtlich der
Befestigung des Warmwasserspeichers an der Wand kann eine
Beschädigung des Geräts, sonstiger Geräte im Raum, Korrosion des
Mantels oder schwerwiegendere Schäden und Mängel verursachen.
Die in diesem Fall entstandenen Schäden liegen nicht in der Garantie-
verantwortung des Verkäufers und der Herstellers und gehen zu Lasten
der Person, die hier angegebenen Hinweise nicht beachtet hatte. Nur
fachkundige Personen dürfen den Warmwasserspeicher an der Wand
installieren.
ANSCHLUSS DES WARMWASSERSPEICHERS
AN DIE WASSERLEITUNG
Die Wasserleitung, an die der Warmwasserspeicher angeschlossen wird,
und alle zugehörigen Bestandteile müssen für dauerhafte Temperaturen ab
80 °С, kurzzeitig ab 100 °С, und für einen Druck ausgelegt sein, der
mindestens das Zweifache des Betriebsdrucks des Geräts beträgt.
Bei dem Anschluss des Warmwasserspeichers an die Wasserleitung bitte
die Pfeile und die Hinweisringe um die Kalt- und Warmwasserrohre (Zu- und
Rücklaufleitung) beachten. Das Kaltwasserrohr hat einen blauen Ring und
ist mit einem Pfeil zum Rohr gekennzeichnet. Ein Pfeil vom Rohr aus – auf
einem rot markierten Rohr kennzeichnet das Warmwasserrohr. Die Rohre
mancher Geräte sind zusätzlich mit Aufklebern gekennzeichnet. Die
Rohranschlüsse haben 1/2” Gewinde. Eine schematische Darstellung des
Anschlusses des Warmwasserspeichers ist auf Fig. 8 gezeigt.
Der Warmwasserspeicher funktioniert mit dem Druck der Wasserleitung
und des Sicherheitsventils. Ist der Druck der Wasserleitung höher als 0,5
MPa, so muss ein Reduzierventil unbedingt installiert werden. Falls
zusätzlicher Zubehör, der nicht in dem Lieferumfang enthalten ist, gemäß
den örtlichen Vorschriften eingesetzt werden muss, ist er entsprechend den
Vorgaben zu kaufen und zu installieren.
16
DE DE
Der Warmwasserspeicher ist mit einem kombinierten Rückschlagventil
ausgestattet. Letzteres ist werkseitig an der Kaltwasserleitung montiert
oder befindet sich in der Verpackung des Gerätes. Das kombinierten
Rückschlagventil, das sich in der Verpackung des Geräts befindet, MUSS
ZWINGEND an der Kaltwasserleitung montiert werden. Während dieser
Installation muss der Pfeil auf dem Rumpf, der die Richtung des
Wasserflusses durch das Ventil anzeigt, befolgt werden.
WARNUNG! Das Fehlen oder der unsachgemäße Einbau des mit dem
Produkt gelieferten Kombiventils führt zum Erlöschen der
Produktgarantie.
WA R N U N G ! D i e M o n t ag e je gl i ch e r A b sp e rr - o d er
Rückschlagarmaturen zwischen dem kombinierten Ventil und dem
Warmwasserspeicher IST VERBOTEN! Das Versperren der seitlichen
Öffnung des kombinierten Ventils und/oder das Arretieren seines Hebels
sind streng verboten!
Für den Fall, dass die Wasserleitungsrohre aus Kupfer oder aus sonstigem
Metall hergestellt sind, das unterschiedlich ist von dem Metall des
Wasserbehälters ist, wie auch wenn Verbindungselemente aus Messing
eingesetzt werden, ist obligatorisch, Nichtmetallarmaturen an der Zulauf-
und Rücklauseite des Warmwasserspeichers zu montieren (dielektrische
Armaturen).
WICHTIG! Bei den Geräten mit Wärmetauschern sind sämtliche
zusätzliche Rohrausgänge (ausgenommen Rohr der Heizschlange), die
nicht an die Wasserleitung angeschlossen werden, wie auch die
Öffnungen für die zusätzlichen Thermostate, mit den in der Verpackung
enthaltenen Teilen oder mit anderen geeigneten Teilen zu verschließen.
Die Verbindungen müssen bei mindestens 1,6 MPa wasser-druckfest
bleiben.
Wir empfehlen, ein Abflusssystem zur Ableitung des ggf. von der seitlichen
Öffnung des kombinierten Ventils tropfenden Wassers zu bauen. Die
Ablassleitung muss mit konstantem Gefälle und in einer frostfreien
Umgebung ausgeführt werden. Sie muss stets offen bleiben.
Nach erfolgtem Anschluss des Warmwasserspeichers an die
Wasserleitung ist der Wasserbehälter mit Wasser zu befüllen. Die
Reihenfolge der auszuführenden Schritte ist:
џWarmwasserhahn der entferntesten Mischbatterie ganz öffnen.
џAbsperrventil öffnen (4 auf Fig. 8)
џAbwarten, bis die Luft aus der Anlage heraustritt und aus der
Mischbatterie ein starker Wasserstrahl innerhalb von 30 Sekunden bis
einer Minute herausfließt.
џWarmwasserhahn der Mischbatterie schließen.
џDen kleinen Hebel des kombinierten Ventils (5 auf Fig. 8) heben, 30-
60 Sekunden abwarten, bis aus der seitlichen Öffnung des Ventils ein
starker Wasserstrahl fließt.
џVentilheben lösen.
WARNUNG! Fließt kein Wasser aus der Ventilöffnung oder fließt nur ein
dünner Strahl (bei normalem Wasserdruck in der Leitung), dann deutet
das auf eine Fehlfunktion hin und zeigt, dass Verunreinigungen in der
Wasserleitung oder am Abwasseranschluss, welche das
Sicherheitsventil des kombinierten Ventils verstopfen können.
Es ist VERBOTEN, den elektrischen Anschluss des Gerätes auszuführen,
solange die Störung nicht behoben ist!
WARNUNG! Bei Nichteinhaltung der Anforderungen für den Anschluss
an die Wasserleitung wird der Wasserbehälter nicht mit Wasser gefüllt,
was zur Fehlfunktion des Heizelements führt. Ist das kombinierte Ventil
nicht oder falsch montiert, kann das eine Zerstörung des
Wasserbehälters, des Raums und/oder andere Sach- und
Personenschäden verursachen. Die daraus entstandenen Schäden
liegen nicht im Rahmen der Gewährleistung des Herstellers und des
Verkäufers und gehen zu Lasten der Person, die die Hinweise aus
diesem Handbuch nicht beachtet hatte.
WARNUNG! Das kombinierte Sicherheits- und Rückschlagventil gehört
zu d en Sc h ut z ei n ri c ht u ng e n, di e die S ic he r he i t d es
Warmwasserspeichers gewährleisten. Es ist streng VERBOTEN, den
Warmwasserspeicher mit beschädigtem oder ausgebautem/nicht
montiertem kombinierten Ventil zu verwenden!
Nur fachkundige Personen dürfen den Warmwasserspeicher an die
Wasserleitung anschließen.
Bei Bedarf kann das Sicherheitsventil auch zum Ablassen des Wassers aus
dem Wasserbehälter dienen. Gehen Sie in diesem Fall wie folgt vor:
џTrennen Sie den Warmwasserspeicher von dem Stromnetz und
schalten Sie sicherheitshalber die Stromsicherung in der
Phasenschleife zum Warmwasserspeicher aus.
џUnterbrechen Sie den Zugang zum Kaltwasser, in dem Sie den Hahn
zudrehen (4 auf Fig. 8).
џÖffnen Sie den Warmwasserhahn der Mischbatterie oder trennen Sie
das Warmwasserrohr (Rücklaufleitung) des Warmwasserspeichers.
џHeben Sie den kleinen Hebel des kombinierten Ventils (5 auf Fig. 8)
und warten Sie ab, bis kein Wasser mehr aus dem Ventil heraustritt.
Diese Schritte sichern kein vollständiges Entleeren des Wasserbehälters.
Nur fachkundige Personen dürfen diese Maßnahmen ausführen, weil sie
mit einem Trennen der elektrischen Schaltung des Geräts und mit Abbau
des Flansches von dem Wasserbehälter verbunden sind.
WARNUNG! Es ist STRENG VERBOTEN, den elektrischen Anschluss
des Warmwasserspeichers auszuführen, solange der Wasserbehälter
ganz oder teilweise entleert ist! Vor erneuter Inbetriebnahme des Geräts
zuerst den Wasserbehälter mit Wasser füllen.
WARNUNG! Es ist VERBOTEN, dass der Wärmeträger durch den
rmetauscher des Warmwasserspeichers umläuft, wenn der
Wasserbehälter ganz oder teilweise entleert ist.
WARNUNG! Bei dem Ablassen des Wassers aus dem Wasserbehälter
unbedingt alle erforderlichen Maßnahmen zur Vorbeugung von
Schäden durch das abgelaufene Wasser treffen.
ANSCHLUSS DES WARMWASSERSPEICHERS
MIT WÄRMETAUSCHER AN DIE INSTALLATION
DER ZUSÄTZLICHEN WÄRMEQUELLE
Der Anschluss des Warmwasserspeichers mit Wärmetauscher an einer
alternativen Wärmequelle erfolgt nach Maßgabe aller speziellen
zusätzlichen Anweisungen des Unternehmens, den Entwurf für die
Installation und den Anschluss des Warmwasserspeichers entwickelt hatte.
Sämtliche gelieferte und/oder von diesem Unternehmen empfohlene
Sicherheits-, Überwachungs- und Steuerelemente für den Wärmeträger
sind unbedingt einzubauen.
WARNUNG! Die Montage von Sperrhähnen an beiden Enden (Zu- und
cklauf) des Wärmetauschers ist streng verboten. Wird der
rmetauscher des Warmwasserspeichers vobergehend nicht
verwendet und ist er an die Wärmequelle nicht angeschlossen, so
müssen Sie ihn mit einer für Heizanlagen geeigneten Propyläen-Glykol-
Lösung füllen.
Nur fachkundige Personen eines auf diesem Gebiet spezialisierten
Unternehmens dürfen den Warmwasserspeicher mit Wärmetauscher an
die zusätzliche Wärmequelle entsprechend des von diesem Unternehmen
ausgearbeiteten Entwurfs anschließen.
E L E K T R I S C H E R A N S C H L U S S D E S
WARMWASSERSPEICHERS
WARNUNG! Führen Sie den elektrischen Anschluss des
Warmwasserspeichers nicht aus, wenn Sie nicht sichergestellt haben,
dass der Wasserbehälter mit Wasser gefüllt ist! Bitte überprüfen!
Der Warmwasserspeicher hat eine Schutzart gegen Stromschlag „Klasse І”.
Deswegen ist er an den Erdungskreis der Stromversorgungsanlage
unbedingt anzuschließen.
Eine schematische Darstellung der Warmwasserspeicher ist auf Fig. 10-14.
Die elektrische Stromversorgung des Warmwasserspeichers ist 230 V~ und
erfolgt über einen separaten Stromkreis, mittels dreiadrigen
2
Versorgungskabels mit Querschnitt 2,5 mm je Draht (Phase, Null und
Erdung). Ist das Kabel der elektrischen Stromversorgung des Raums
zweiadrig, soll ein Fachmann einen zusätzlichen Schutzleiter installieren,
dessen Strecke von der Schaltanlage bis zum Warmwasserspeicher nicht
unterbrochen werden darf. Hat der Schutzleiter/Schutzader dazwischen
liegende Verbindungen, so sind diese gegen Selbstlösen zu sichern.
Ansonsten ist das Gerät nicht ordnungsgemäß geerdet, was seine
Sicherheit beeinträchtigen wird.
WA R N U N G ! E s i st i m s pe is e n de n S tr om k r ei s d es
Warmwasserspeichers UNBEDINGT eine solche Vorrichtung
17
DE DE
einzubauen, die bei Überspannung ІІІ-er Kategorie eine sichere und
komplette Trennung aller Pole gehrleistet. Die Leitungen des
Stromkreises zwischen dieser Vorrichtung und dem elektrischen
Eingangsklemmen des Warmwasserspeichers müssen nicht von einem
anderen Schalter oder einer anderen Sicherung getrennt werden. Die
Trennvorrichtung soll außerhalb des Raums, in dem sich der
Warmwasserspeicher befindet, montiert werden, falls darin auch eine
Duschkabine und/oder Wanne installiert sind.
Sämtliche Leitungsenden des Stromkreises des Geräts sind fachgerecht an
die Hauptschalttafel, an die optionale Einrichtung und an den
Anschlusspunkt des Warmwasserspeichers zur elektrischen
Stromversorgung anzuschließen. Eine Stromsicherung 10A ist in dem
Stromkreis bei Leistung des Heizelements des Geräts bis 2 kW bzw. 16 А
bei Leistung des Heizelements 3 kW einzubauen. Die elektrische
Stromversorgungsanlage soll nach Maßgabe der geltenden Vorschriften
ausgeführt werden. Wir empfehlen für den Fall, dass das gesetzlich nicht
vorgeschrieben ist, eine automatische Fehlerstromsicherung in dem
S t r o m k r e i s d e s W a r m w a s s e r s p e i c h e r s e i n z u b a u e n
(Reststromvorrichtung).
Bevor Sie das Versorgungskabel an die Klemmen des Geräts anschließen,
müssen Sie den Kunststoffdeckel sorgfältig abnehmen, so dass die
Stromleitungen im Gerät nicht getrennt werden. Entsprechend der auf der
Innenseite des Deckels aufgeklebten elektrischen Schaltung den
Phasenleiter des Versorgungskabels an die mit L (bzw. A1, je nach der
Ausführung) gekennzeichnete Klemme, den Nullleiter an die N-Klemme
(bzw. B1) und den Schutzleiter an die mit dem Symbol der Schutzerdung
gekennzeichneten Schutzklemme (Schraube oder Stiftschraube)
anschließen. Das Versorgungskabel unbedingt gegen Verschieben mit
Hilfe der unmittelbar an der Bohrung für das Kabel auf dem Kunststoffdeckel
gelegenen Kabelschelle sichern. Anschließend den Kunststoffdeckel
wieder anbringen und einschrauben und darauf achten, dass die Leiter und
die Kapillarrohre des Thermostats und des Wärmeauslösers frei liegen.
Der elektrische Anschluss bei Warmwasserspeichern mit werkseitig
gebauten Versorgungskabeln mit Stecker erfolgt durch Einstecken des
Steckers in einer fehlerfrei funktionierenden Netzsteckdose im Raum.
Dabei muss die Steckdose an einen separaten, nur für den
Warmwasserspeicher vorgesehenen Stromkreis angeschlossen werden
und so liegen, dass sie auch nach der Installation des Geräts zugänglich ist.
Der Querschnitt der Stromleitungen der Stromanlage, an die die Steckdose
angeschlossen ist, ist so auszulegen, dass er für die elektrische Leistung
des Warmwasserspeichers geeignet ist. Eine Stromsicherung (10A bei
Leistung bis 2 kW bzw. 16 А bei Leistung 3 kW) ist in den Stromkreis
einzubauen. Die Anlage soll nach Maßgabe der Normativdokumente
ausgeführt werden. Der Warmwasserspeicher ist aus der
Stromversorgungsanlage vollständig getrennt, indem man den Stecker des
Versorgungskabels aus der Steckdose zieht. Eine fehlerhafte und/oder
nicht geeignete Stromanlage und/oder Steckdose stellt eine hohe Gefahr
dar und kann einen Unfall verursachen, zur Beschädigung des Produkts
führen und der Umwelt, Gegenständen oder Lebewesen schaden.
Nach Ausführung des elektrischen Anschlusses die Funktionsfähigkeit des
Geräts unbedingt prüfen.
WARNUNG! Die Nichteinhaltung der Anforderungen für den
elektrischen Anschluss beeinträchtigt die Gerätesicherheit, so dass der
Warnwasserspeicher nicht verwendet werden darf. Die negativen
Auswirkungen infolge Nichterfüllung der Anforderungen für den
elektrischen Anschluss des Geräts liegen nicht in dem Umfang der
Garantieverpflichtungen des Herstellers und des Verkäufers und gehen
zu Lasten der Person, die die in diesem Handbuch gegebenen Hinweise
nicht beachtet hatte.
Nur fachkundige Personen dürfen den Warmwasserspeicher an die
Stromversorgungsanlage anschließen und seine Funktionstüchtigkeit
überprüfen, diese Maßnahmen liegen nicht in dem Verantwortungsbereich
des Herstellers oder des Händlers und sind gehören nicht zu der
Garantiebedienung.
BETRIEB DES WARMWASSERSPEICHERS
Der Warmwasserspeicher wird in der Betriebsart eingeschaltet, indem die
mit „I“ gekennzeichnete Wippe des leuchtenden Wippschalters gedrückt
wird. Die gewünschte Wassertemperatur wird über den Drehknopf
eingestellt. Das Leuchten des Wippschalters in On-Stellung zeigt, dass das
Heizelement funktioniert und das Wasser erhitzt wird. Leuchtet der
Wippschalter nicht mehr, hat das Wasser die voreingestellte Temperatur
erreicht und das Heizelement ist ausgeschaltet. Sie können das Gerät
ausschalten, indem Sie die mit0 gekennzeichnete Wippe des
Wip ps c ha lt e rs drüc k en . D as voll st ä nd ig e Tren ne n des
Warmwasserspeichers von dem Netz erfolgt durch eine zusätzliche
Trennvorrichtung.
Bei den mit „D“ in der Nummer gekennzeichneten schaltet jede Wippe des
auf der Steuertafel liegenden leuchtenden Wippschalters ein Heizelement
ein/aus. Dadurch kann man die halbe oder die volle Leistung des Geräts, je
nach den konkreten Bedürfnissen und nach der gewünschten Zeit, für die
Wassererwärmung nutzen.
Die Geräte mit Modellnummern 722xxW(WN;WD;WND) (Abb. 1c) sind mit
einem Schalter ausgestattet und neben dem Temperaturregler befindet sich
eine Lichtdiode, die den Betriebsstatus anzeigt. Die Geräte mit
Modellnummern 722xxWG(WNG) sind ohne Schalter und erfordern die
Montage eines zusätzlichen Einschaltbedienfeldes zum Trennen vom
elektrischen Netz.
Auf der Grafik um den Drehknopf ist ein ECO Bereich gezeigt. Befindet sich
die Kennzeichnung des Drehknopfs in diesem Bereich, so wird das Wasser
bis zu einer optimalen Temperatur erwärmt, so dass die Wärmeverluste und
der Stromverbrauch reduziert werden. Gleichzeitig reicht das erwärmte
Wasser für den normalen Verbrauch im Haushalt aus. Werden größere
Wassermengen gebraucht, müssen Sie den Drehknopf im Uhrzeigersinn,
zur maximalen Stellung drehen, damit das Wasser in dem
Warmwasserspeicher auf höhere Temperaturen erwärmt wird. Wir
empfehlen, den Drehknopf in dem ECO Bereich einzustellen, wenn der
Warmwasserspeicher für längere Zeiten eingeschalten bleibt und das
erwärmte Wasser nicht sofort verbraucht wird.
Der eingebaute Thermostat hat eine Antifreeze-Funktion. Befindet sich der
Drehknopf des Thermostats in Endstellung links, am Anfang der Skala, so
wird sich das Heizelement bei Umgebungstemperatur 8-10 °С einschalten
und bei ca. 12-15 °С ausschalten. Auf diese Weise frostet das Wasser in
dem Wasserbehälter nicht ein, wenn die Temperatur der Raumluft absinkt.
WICHTIG! Diese Funktion schützt das Wasser in der Wasserleitung des
Raums nicht vor Einfrieren!
Das Ein- und Ausschalten, die Einstellung und die Bedienung der
Warmwasserspeicher mit elektronischer Steuerung erfolgen nach
Maßgabe der Vorschriften und Anforderungen, die in der mitgelieferten
Anschluss- und Betriebsanleitung eines Gets mit elektronischer
Steuerung angegeben sind. Bei diesen Geräten stellt die zusätzliche
Anleitung ein Bestandteil dieser Montage- und Gebrauchsanleitung dar.
Der auf der Außenverkleidung des Geräts montierte Thermometer zeigt den
Prozess der Wassererwärmung. Das ist kein Messgerät. Die Vorrichtung
zeigt nur die ungefähre Temperatur und die vorhandene
Warmwassermenge in dem Wasserbehälter.
WARNUNG! Schalten Sie niemals das Gerät ein, wenn
Wahrscheinlichkeit besteht, dass das Wasser in dem Wasserbehälter
eingefroren ist! Dadurch können das Heizelement und der
Wasserbehälter beschädigt werden.
WARNUNG! Dieses Gerät darf von Personen (einschließlich Kindern ab
8 Jahre) mit eingeschränkten körperlichen oder geistigen Fähigkeiten
nur verwendet werden, wenn diese Personen unter der Aufsicht einer
verantwortlichen Person stehen oder von dieser Person in den
Gebrauch des Geräts eingewiesen wurden. Kinder müssen
beaufsichtigt werden, damit sie in keinem Fall mit dem Gerät spielen. Es
ist verboten, dass Kinder das Gerät reinigen oder bedienen.
In dem kombinierten Ventil ist ein spezielles Ventil eingebaut, welches bei
Normalbetrieb des Warmwasserspeichers ermöglicht, dass das sich
während des Erhitzens ausdehnende Wasser nicht aus der seitlichen
Ventilbohrung tropft, sondern der Kaltwasserleitung zugeführt wird. Dabei
handelt es sich um eine minimale Wassermenge mit niedriger Temperatur.
Bei Normalbetrieb des Warmwasserspeichers und wenn ein zusätzliches
Rückschlagventil vorhanden ist, kann möglicherweise Wasser aus der
seitlichen Ventilbohrung tropfen. Das ist kein Defekt und die seitliche
Ventilbohrung sollte auf keine Art und Weise verstopft werden, weil
ansonsten der Wasserbehälter beschädigt wird.
Das in dem Ventil eingebaute Sicherheitsventil verhindert, dass das Wasser
aus dem Wasserbehälter, für den Fall eines Ausfalls der Kaltwasserleitung,
zugeführt wird.
18
DE DE
Die eingebauten Wärmetauscher (falls vorhanden) zur Erwärmung des
Wassers im Wasserbehälter werden entsprechend der speziellen
zusätzlichen Gebrauchsanleitung betrieben. Diese Gebrauchsanleitung
wird von denjenigen Personen zur Verfügung gestellt, die die Planung und
die Installation der Warmwasserbereitungsanlage mittels Wärmequellen
ausgehrt hatten. Die dort beschriebenen Regeln sind unbedingt
einzuhalten.
Möglicherweise kann man Geräusche bei der Erwärmung des Wassers
hören, wenn das Gerät in Regionen mit kalkhaltigem Wasser verwendet
wird. Das ist auf den während dieses Prozesses auf das Heizelement und in
dem Wasserbehälter gelagerten Kalkstein zurückzuführen. Die
Kalksteinmenge hängt von dem Wasser und von der Temperatur der
Erwärmung ab. Ist diese Temperatur höher als 60 °С, so steigt auch die
Kalksteinmenge. Der abgelagerte Kalkstein beeinträchtigt den Betrieb des
Heizelements, kann es beschädigen und verlängert die für die Erwärmung
der Wassermenge notwendige Zeit.
Sie hören möglicherweise ein leises Geräusch während des Betriebs des
Warmwasserspeichers, das auf den Durchfluss des Wassers durch die
Rohrleitung und durch das Gerät wie auch auf die natürlichen Prozesse der
Wärmedehnung und Wärmeableitung zurückzuführen ist.
Wird der Warmwasserspeicher in der Regel zur Erwärmung von Wasser auf
niedrigeren Temperaturen verwendet, empfehlen wir, den Thermostat
mindestens einmal monatlich auf Max zu drehen und das Wasser auf
Höchsttemperatur zu erwärmen und für mindestens 24 Stunden zu
erhalten, um das Wachstum von Legionellen zu vermeiden.
ZUSÄTZLICHER KORROSIONSSCHUTZ
Warmwasserspeicher mit emailliertem Wasserbehälter. In jedem
Warmwasserspeicher mit emailliertem Wasserbehälter ist ein zusätzlicher
Korrosionsschutz eingebaut. Dieser Korrosionsschutz besteht aus einer
aus spezieller Legierung hergestellten Anode, die nur bei mit Wasser
gefülltem Wasserbehälter funktioniert. Die Anode ist ein Verbrauchsartikel
(d.h. ein Teil mit normaler Abnutzung während des Gerätebetriebs), seine
durchschnittliche Lebensdauer beträgt höchstens 3 Jahre. Diese
Lebensdauer hängt insbesondere von der Betriebsart des Geräts und von
den Merkmalen des zu erwärmenden Wassers ab. Nach Ablauf dieser Zeit
soll ein Fachmann des von dem Hersteller oder dem Verkäufer autorisierten
Kundendienstes den Zustand der Anode prüfen und ggf. erneuern. Die
Einhaltung der Frist und die rechtzeitige Erneuerung der Anode sind
wichtige Bedingungen für den effizienten Korrosionsschutz des
Wasserbehälters. Die Prüfung und die Erneuerung der Anode gehören nicht
zu den Garantiepflichten des Herstellers und des Händlers.
Warmwasserspeicher mit emailliertem Wasserbehälter und
Anodentester. Das Vorhandensein des Anodentesters ist wichtig für den
Betrieb des Warmwasserspeichers. Bei manchen Ausführungen der
Warmwasserspeicher mit konventionellem Thermostat wird ein
elektromechanischer Anodentester eingebaut (Fig. 9). Dieser besteht aus
einem Pfeilsystem mit Skala und aus einem Umschalter (Taste). Die Skala
hat zwei Sektoren einen roten und einen grünen. In dem normalen
Betriebszustand des Warmwasserspeichers befindet sich der Pfeil des
Testers im roten Bereich – der Tester ist nicht eingeschalten und die Anode
funktioniert normal. Die Funktionstüchtigkeit der Anode wird bei vollständig
erwärmter Wassermenge geprüft (Thermostat aus, d.h. die leuchtende
Taste leuchtet nicht), indem man die Taste des Testers für einige Sekunden
lang drückt. Der Pfeil wird zum grünen Bereich der Skala abweichen. Die
Größe der Abweichung richtet sich nach den Parametern des Wassers und
der Wasser-temperatur, wobei die Grenzen beider Bereiche den
Durchschnittswerten des Wassers entsprechen.
Die Abweichung des Pfeils ist ein Zeichen für die Funktion-stüchtigkeit der
Anode. Weicht der Pfeil beim Drücken der Taste des Testers nicht ab oder
bleibt er im roten Bereich stehen, müssen Sie den nächsten, von dem
Hersteller oder dem Verkäufer autorisierten Kundendienst kontaktieren. Ein
Fachmann wird den Korrosionsschutz pfen und die notwendigen
Maßnahmen ergreifen. Die elektronische Steuerung mancher
Modifikationen der Warmwasserspeicher werden der Betrieb und der Grad
der Abnutzung der Anode durch periodisch aufeinander folgendes Ein- und
Ausschalten eines Displayteils angezeigt. Die Fläche des leuchtenden Teils
verringert sich mit der Erhöhung des Abnutzungsgrades der Anode. Nähere
Informationen finden Sie in der zusätzlichen Anleitung, die für jeden
Warmwasserspeicher mit elektronischer Steuerung mitgeliefert wird.
Leuchtet das ganze Display nicht mehr, müssen Sie den nächsten
Kundendienst kontaktieren, um die Anode prüfen und ggf. erneuern zu
lassen.
Warmwasserspeicher mit Wasserbehälter aus hochlegiertem Chrom-
Nickel-Stahl. Der Korrosionsschutz und die garantierte Lebensdauer sind
gesichert, wenn die Stahlsorte, die Konstruktion und das
Herstellungsverfahren für den Wasserbehälter richtig gewählt sind.
WARTUNG, INSTANDHALTUNG, BEDIENUNG
Für den sicheren Betrieb des Warmwasserspeichers in Regionen mit
kalkhaltigem Wasser empfehlen wir, den Wasserbehälter vom
angesammelten Kalkstein zu reinigen. Diese Reinigung sollte mindestens
einmal alle zwei Jahre durchgeführt werden, in den Regionen mit
kalkhaltigem Wasser sogar öfters. Die Ablagerungen auf der
Emaillebeschichtung müssen nicht abgekratzt, sondern nur mit einem
trockenen Baumwolltuch abgewischt werden. Die regelmäßige Reinigung
und Beseitigung des Kalksteins ist für den sicheren Betrieb des Geräts
besonders wichtig. Es ist wünschenswert, zur selben Zeit auch die Anode
des emaillierten Wasserbehälters zu kontrollieren. Diese Leistungen
gehören nicht zum Gewährleistungsumfang und sind durch fachkundige
Personen auszuführen.
WARNUNG! Zur Gewährleistung eines einwandfreien und sicheren
Betriebs des Warmwasserspeichers ist das kombinierte Ventil
regelmäßig auf ggf. reduzierte Durchlässigkeit zu prüfen. Dazu den
kleinen Hebel heben und ca. 30-60 Sekunden abwarten, bis ein starker
Wasserstrahl aus der seitlichen Ventilbohrung heraustritt. Diese Prüfung
ist unbedingt nach Anschließen des Warmwasserspeichers an die
Wasserleitung und nach Füllen des Wasserbehälters mit Wasser, bei
Verwendung des Warmwasserspeichers mindestens alle zwei
Wochen sowie nach Ausfall und Wiederherstellung der
Wasserversorgung durchzuführen. Flit kein Wasser aus der
Ventilöffnung, wenn der Warmwasserspeicher mit Wasser gefüllt ist,
oder fließt nur ein dünner Strahl, dann deutet das auf eine Fehlfunktion
hin und zeigt, dass Verunreinigungen in der Wasserleitung das Ventil
verstopft hatten. Es ist verboten, einen Warmwasserspeicher mit
beschädigtem kombiniertem Ventil zu betreiben. Trennen Sie das Gerät
sofort von dem Netz und kontaktieren Sie den nächsten, von dem
Hersteller autorisierten Kundendienst. Ansonsten kann der
Wasserbehälter beschädigt werden. Auch andere Schäden an
Gegenständen und an dem Raum, in dem der Warmwasserspeicher
installiert ist, können entstehen.
Besteht der Verdacht, dass die Raumtemperatur, in dem der
Warmwasserspeicher installiert ist, unter 0 °C fallen kann, muss das
Wasser in dem Wasserbehälter UNBEDINGT abgelassen werden – siehe
den AbschnittAnschluss des Warmwasser-speichers an die
Wasserleitung”.
Die Außenhülle und die Kunststoffteile des Warmwasserspeichers sind nur
mit leicht feuchtem Baumwolltuch, ohne aggressive und/oder Scheuermittel
zu reinigen. Das Gerät vor dem Reinigen UNBEDINGT mit Hilfe der
zusätzlichen Trennvorrichtung vom Netz trennen oder durch Abziehen des
Steckers aus der Steckdose ausschalten. Es ist VERBOTEN, das Gerät mit
einem Dampfgerät zu reinigen. Insbesondere weisen wir darauf hin, dass
der leuchtende Schalter zum Ein- und Ausschalten des Geräts, der sich auf
dem Bedienfeld befindet, in keinen Kontakt mit Wasser treten darf. Der
Warmwasserspeicher kann erst nach vollsndiger Entfernung der
Feuchtigkeit wieder in Betrieb genommen werden.
Die Vorschriften zur Kontrolle des Anodenschutzes und zur Erneuerung der
Anode (siehe vorigen Punkt), und die Beseitigung des gesammelten
Kalksteins sind sowohl während als auch nach Ablauf der Garantiefrist des
Geräts einzuhalten.
Schützen Sie das Metall-Typenschild mit angegebener Fabriknummer
(Seriennummer) während der Verwendung und der Wartung des Geräts.
Falls Sie ihn entfernen, bitte samt Garantiekarte aufbewahren, weil sie zur
Identifizierung des Geräts dienen.
STÖRUNGEN
Erwärmt der Warmwasserspeicher das Wasser nicht, prüfen Sie, ob die
externe Trennvorrichtung nicht ausgeschalten, der leuchtende Schalter
nicht in Aus-Stellung ist und ob der Drehknopf des Thermostats nicht in
19
DE DE
niedrigster Position gedreht ist.
Ist die Stromversorgung OK, der leuchtende Schalter in ON-Stellung und
der Drehknopf in höchster Position und wird das Wasser trotzdem nicht
erwärmt (dabei können der leuchtende Schalter oder die Signallampe
leuchten oder nicht leuchten), müssen Sie den Warmwasserspeicher mit
Hilfe der externen Vorrichtung ausschalten und den nächstgelegenen
autorisierten Kundendienst kontaktieren.
Falls aus dem Mischer kein Wasser oder nur ein dünner Wasserstrahl fließt,
obwohl der Warmwasserhahn vollständig geöffnet ist, müssen Sie den Filter
am Auslass des Mischers auf Verstopfung überprüfen. Prüfen Sie auch, ob
der Sperrhahn vor dem Warmwasserspeicher (4 auf Fig. 8) ganz oder
teilweise geschlossen ist, ob die zentrale Wasserversorgung nicht
eingestellt ist. Sind alle obigen Prüfungen OK, ssen Sie den
Warmwasserspeicher mit Hilfe der externen Trennvorrichtung vom Netz
trennen und den nächstgelegenen autorisierten Kundendienst
kontaktieren.
Für Warmwasserspeicher mit Steuerelektronik finden Sie am Ende der
zusätzlichen spezialisierten Anleitung alle auf dem Display angezeigten
Funktionen und Fehlermeldungen beschrieben; auch Informationen über
die zu ergreifenden Maßnahmen sind angegeben. Im Allgemeinfall müssen
Sie den Warmwasserspeicher mit Hilfe der externen Trennvorrichtung vom
Netz trennen und den nächstgelegenen autorisierten Kundendienst
kontaktieren.
Bei Störung des Versorgungskabels und/oder des Steckers des
Warmwasserspeichers bitte den nächsten, von dem Hersteller/Verkäufer
autorisierten Kundendienst kontaktieren. Das Versorgungskabel und der
Stecker sind durch den Hersteller, durch seinen Vertriebshändler oder
durch eine fachkundige Person zu ersetzen, damit jegliche Gefahr
vermieden wird.
GEWÄHRLEISTUNG, GEWÄHRLEISTUNGSFRIST
UND GARANTIEBEDINGUNGEN
In allen Fällen sind auch die einschlägigen Gesetze, Verordnungen und die
anderen Normativdokumente über die Rechte und die Pflichten des
Verbrauchers, des Verkäufers und des Herstellers, über ihre Beziehungen
in Bezug auf den gekauften Warmwasserbereiter, über seine Installation,
Verwendung, Wartung und Instandhaltung anzuwenden.
Die Garantiefrist wird von dem Händler bestimmt und gilt nur für das
geographische Gebiet des jeweiligen Landes.
Die Garantie des Geräts gilt nur unter folgenden Bedingungen:
џDas Gerät ist entsprechend den Montage- und Gebrauch-
sanleitungen installiert.
џDas Gerät wird nur zweckgemäß und nach Maßgabe der Montage-
und Gebrauchsanleitungen verwendet.
Die Garantie umfasst die Behebung sämtlicher Fabrikationsfehler, die
während der Garantiezeit auftreten können. Nur die vom Verkäufer
autorisierten Fachleute dürfen die Reparaturen vornehmen.
Die Garantie deckt keine Schäden aus:
џUnsachgemäßem Transport
џUnsachgemäßer Lagerung
џUnsachgemäßem Gebrauch
џWasserparametern, die über die zulässigen Qualitätsnormen für
Trinkwasser hinausgehen, insbesondere: Chloridgehalt ab 250 mg/l;
elektrische Leitfähigkeit bis 100 µS/cm und/oder pH außer 6,5-8 r
Warmwasserbereiter mit emailliertem Wasserbehälter; elektrische
Leitfähigkeit ab 200 µS/cm für Warmwasserbereiter mit Wasserbehälter
aus Chrom-Nickel-Stahl
џNetzspannung, die von der Nennspannung abweicht
џSchäden wegen Einfrieren des Wassers
џAußergewöhnliche Risiken, Unfälle oder sonstiger höherer Gewalt
џNichtbeachtung der Montage- und Gebrauchsanleitung
џIn allen Fällen, wenn eine nicht autorisierte Person das Gerät zu
reparieren versucht.
In den vorgenannten Fällen wird der Schaden gegen Bezahlung behoben.
Die Garantie des Geräts gilt nicht für Teile und Komponenten des Geräts,
die während seiner üblichen Anwendung abgenutzt werden, auch nicht für
Teile, die während des normalen Gebrauchs abgebaut werden, für
Leuchten und Signallampen etc., für Verfärbung von externen Oberflächen,
für Änderung der Form, der Abmessung und der Anordnung von Teilen und
Komponenten, die einer den normalen Bedingungen für Verwendung des
Geräts nicht entsprechenden Auswirkung ausgesetzt worden sind.
Versäumte Nutzen, materielle und immaterielle Schäden infolge
vorübergehender Unmöglichkeit zur Verwendung des Geräts in der Zeit
seiner Reparatur und Wartung, werden von der Garantie des Geräts nicht
gedeckt.
DIE EINHALTUNG ANGEGEBENEN ANFORDERUNGEN IM
HANDBUCH IST VORAUSSETZUNG FÜR DEN SICHEREN
BETRIEB DES GEKAUFTEN PRODUKTS UND ZÄHLT ZU DEN
GARANTIEBEDINGUNGEN.
JEGLICHE, VOM BENUTZER ODER VON DEN VON IHM
BEVOLLMÄCHTIGTEN PERSONEN VORGENOMMENE
ÄNDERUNGEN UND UMBAUTEN AN DER KONSTRUKTION DES
PRODUKTS SIND STRENG VERBOTEN. WERDEN DERARTIGE
HANDLUNGEN ODER VERSUCHE FESTGESTELLT, DANN SIND
AUCH DIE GARANTIEPFLICHTEN DES HERSTELLERS ODER DES
NDLERS UNWIRKSAM.
DER HERSTELLER BEHÄLT SICH DAS RECHT VOR,
STRUKTURVERÄNDERUNGEN OHNE ANKÜNDIGUNG
VORZUNEHMEN, SOFERN DIE SICHERHEIT DES RPODUKTS
NICHT BEEINTRÄCHTIGT WIRD.
FALLS NOTWENDIG ODER WENN MISSVERSTÄNDNISSE IM
ZUSAMMENHANG MIT DER ÜBERSETZUNG UND MIT DEN IN
DI E SE R S PR A CH VE RS IO N D ER MO NTA G E- UN D
GEBRAUCHSANLEITUNG VERWENDETEN BEGRIFFEN
BESTEHEN, BITTE DIE ENGLISCHE VERSION ALS ORIGINAL UND
ALS VORRANGIGE VERSION BENUTZEN.
20
DE DE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Eldom Invest 30-150 Household Electric Water Heaters Instrucțiuni de utilizare

Tip
Instrucțiuni de utilizare