Mellanox Technologies MSX6512-4R Hardware Installation Manual

Tip
Hardware Installation Manual

Acest manual este potrivit și pentru

www.mellanox.com
216-Port InfiniBand FDR SwitchX®
Switch Platform Hardware Installation Guide
PN:MSX6512-4R. MSX6512-NR
Rev 1.4
Document Number: 3877
Mellanox Technologies
2
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
3
Table of Contents
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 1 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 Installation Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.2 Environmental and Safety Recommendations . . . . . . . . . . . . . . . . . . . . 15
1.3 Chassis Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.4 Leaf Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.5 Spine Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.6 Management Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.7 Physical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.7.1 ESD Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.7.2 Installing the Cable Holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.7.3 Installing the Chassis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
1.7.4 Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
1.8 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
1.8.1 Powering Up the Switch Platform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
1.9 InfiniBand QSFP Cable Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
1.9.1 Supported Approved Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
1.9.2 Cable Power Classes. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 36
1.10 Hot Swap Insertion and Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
1.10.1 Power Supply Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.10.2 Leaf Boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
1.10.3 Spine Boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
1.10.4 Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
1.10.5 Management Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
1.10.6 Switch Shut-Down Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Chapter 2 Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.1 LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.1.1 Power Supply Unit LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.1.2 Leaf Board LED Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.1.3 Spine Board LED Indicators. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 56
2.1.4 Spine Side Panel Display LED Indicators . . . .
. . . . . . . . . . . . . . . . . . . . 58
2.1.5 Management Module LED Indicators. .
. . . . . . . . . . . . . . . . . . . . . . . . . . 60
2.1.6 Port Connector Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2.2 Air Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2.3 QSFP Cable Power Budget Classification. . . . . . . . . . . . . . . . . . . . . . . . 62
2.4 Management Module Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2.4.1 I2C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.4.2 CONSOLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.4.3 MGT– Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.4.4 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
4
2.4.5 Reset – RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Chapter 3 Chassis Power Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
3.1 Power Supply and Spine Board Indicator Status at Power ON. . . . . . . . 66
Chapter 4 First-Time Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.1 Running the Wizard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.2 Re-Running the Wizard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.3 Starting the Command Line (CLI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.4 Starting the Web User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Chapter 5 Resetting the Switch – RST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Chapter 6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
6.1 Power Supply Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
6.2 Leaf Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
6.3 Management Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
6.4 Spine Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
6.5 MLNX-OS® Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Chapter 7 Disassembly and Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7.1 Disassembling the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7.1.1 Removing the Chassis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7.1.2 Removing the Bottom Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7.2 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Appendix A Installation Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
A.1 Installation Safety Warnings (English) . . . . . . . . . . . . . . . . . . . . . . . . 81
A.2 安裝安全性警告 (Chinese) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
A.3 Avertissements de sécurité pour l'installation (French) . . . . . . . . . . . 90
A.4 Installation Sicherheitshinweise(German). . . . . . . . . . . . . . . . . . . . . . 95
A.5 Advertencias de seguridad de instalación (Spanish) . . . . . . . . . . . . . 99
A.6 Предупреждения по технике безопасности при установке (Russian) 103
A.7 Avertismente privind siguranţa la instalare (Romanian) . . . . . . . . . . 107
A.8 Sigurnosna upozorenja za instaliranje (Croatian). . . . . . . . . . . . . . . 112
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
5
List of Tables
Table 1: Revision History of this User’s Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 2: Reference Documents and Websites. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 3: Leaf Status LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 4: Bad Port LED Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 5: Connector Physical and Logical Link Indications
. . . . . . . . . . . . . . . . . . . . . . . . 56
Table 6: Spine Status LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 7: Spine Fan Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 8: Spine to Leaf IB Link Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 9: Bad Port LED Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 10: LEDs Display for Normal Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Table 11: LEDs Display for Normal Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 12: Management Module PSU LED Configurations . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 13: Management Module S.Fan LED Configurations . . . . . . . . . . . . . . . . . . . . . . . 61
Table 14: Management Module L.Fan LED Configurations . . . . . . . . . . . . . . . . . . . . . . . 61
Table 15: Management Module MASTER LED Configurations . . . . . . . . . . . . . . . . . . . . 61
Table 16: Serial Terminal Program Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 17: Configuration Wizard Session - IP Configuration by DHCP. . . . . . . . . . . . . . . . 68
Table 18: Configuration Wizard Session - IP Zeroconf Configuration
. . . . . . . . . . . . . . . . 70
Table 19: Configuration Wizard Session - St
atic IP Configuration. . . . . . . . . . . . . . . . . . . 71
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
6
List of Figures
Figure 1: Shelf Installation Kit Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 2: Chassis Installation Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 3: Shock and Tilt Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 4: Opening the Container . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 5: Placement of Chassis in Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 6: Inserting the Caged Nuts for the Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 7: Connect Rail Slide to Rack Vertical support . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 8: Inserting the Caged Nuts for the Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 9: Chassis on Shelf with Filler Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 10: Cable Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 11: Cable Holder Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 12: Chassis Rails and Rail Slides . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . 28
Figure 13: Installing the Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 14: Screw the Handles Onto the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 15: The Rails are Already Connected Onto the Chassis
. . . . . . . . . . . . . . . . . . . . 30
Figure 16: Raising the Chassis Using a Mechanical Lift
. . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 17: Put on the Rail Slide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 18: SX6512 Chassis on the Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 19: Face Plate Mounting Bolt Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 20: Ground Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 21: Multiple Power Inlets – Electric Caution Notification . . . . . . . . . . . . . . . . . . . . . 34
Figure 22: Spine Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 23: Power Cord Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 24: PSU Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 25: Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 26: Leaf Board Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 27: Ejector Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 28: Leaf Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 29: Intact vs Defected Signal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 30: Intact vs Defected Power Pin Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 31: Management Module Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 32: Spine Board Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 33: Intact vs Defected Mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 34: Intact vs Defected Side Signal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 35: Intact vs Defected Middle Signal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 36: Intact vs Defected Power Pin Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 37: Spine Board Insertion Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
7
Figure 38: Leaf Fan Locations on the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 39: Leaf Fan Module Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 40: Spine Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 41: Fan Status LED on the Spine Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Figure 42: Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 43: Intact vs Defected Signal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 44: Intact vs Defected Power Pin Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 45: Power Supply Unit Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 46: PSU Cover On and Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 47: Leaf Board Led Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 48: Spine Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 49: Spine Side Panel Display Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 50: Management Module Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 51: Management Module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 52: Port Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 53: Top and Bottom Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 54: Management Module Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 55: Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 56: Spine Side Panel Display Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 57: Management Module Status Indications for Normal Operation . . . . . . . . . . . . 66
Figure 58: Console Ports for SX60xx/SX65xx Managed Systems . . . . . . . . . . . . . . . . . . . 67
Figure 59: MLNX-OS Login Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 60: EULA Prompt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 61: Display After Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 62: Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
8
Revision History
About this Manual
This manual provides installation and set-up instructions for the SX6512 QSFP Chassis
InfiniBand Switch Platform.
Intended Audience
This manual is intended for users and system administrators responsible for installing
and setting up the chassis platform.
The manual assumes familiarity with the InfiniBand
®
architecture specification.
Table 1 - Revision History of this User’s Manual
Revision Date Details
1.4 Feb. 2014 Rearranged document: Consolidated installation sections under
Chapter 1, “Installation,” on page 11; updated Chapter 1, “Overview,”
on page 12; and re-ordered sections).
Added:
Figure 51, “Management Module LEDs,” on page 60
Updated:
Section 1.4, “Power Supply Redundancy,” on page 15
Section 1.7.1.5, “Installing the Shelf,” on page 22
Section 1.7.2, “Installing the Cable Holder,” on page 26
FDR note in Section 1.9, “InfiniBand QSFP Cable Installation,” on
page 35
Section 1.10, “Hot Swap Insertion and Extraction,” on page 36
Section 7.1, “Disassembling the Chassis,” on page 79
Appendix A, “Installation Safety Warnings,” on page 81
1.3 Oct. 2010
Added warning not to use fan handles to lift or move the chassis.
1.2 Sept. 2010
Added Figure 10.
Added instructions to insert spines from the bottom up.
1.1 Aug. 2012 Leafs, spines, Management modules shipped separately.requiring
Changes to installation procedure
1.0 July 2010 First release
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
9
Related Documentation
The documentation set accompanying the QSFP Chassis InfiniBand Switch platform
includes the following:
Conventions
Throughout this manual, the name SX6512 and the terms chassis and switch are used to
describe the 216 port QSFP InfiniBand chassis, unless explicitly indicated otherwise.
The following icons are used throughout this document to indicat
e information that is
important to the user.
Table 2 - Reference Documents and Websites
Document Name Description
InfiniBand Architecture Specification,
Vol. 1, Release 1.2.1
The InfiniBand Architecture Specification that is provided by
IBTA
Switch Product Release Notes For possible hardware issues see the switch support product
page.
This requires a customer support login. Look up the rele-
vant SwitchX®-based switch system/se
ries release note file.
Mellanox MLNX-OS® User Manual
for
VPI
This document contains information regarding configuring and
managing Mellanox Technologies SwitchX® switch platforms
listing all of the commands available through MLNX-OS with
explanations and examples.
This symbol makes recommendations to the user.
This symbol indicates information that is helpful to the user.
This symbol indicates a situation that can potentially cause damage to hardware or
software.
Warning! This symbol indicates a situation that can potentially cause personal injury
and / or damage to hardware or software.
InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
10
Mellanox Part Numbering Legend
Place Field Decoder
M Mellanox Technologies
SX System Type SwitchX® Switch
PR Data Transfer Protocol (1, 2, 3, 4) = Ethernet (5, 6, 7, 8) = InfiniBand
G Module Generation 5, 6, 7, 8
FF Number of leafs 36, 18, 12, 06
C Data Rate B = 40Gb/s Ethernet
F = FDR, T = FDR10, Q = QDR, D = DDR
- Separator
P # Power Supplies N = N+N redundant
1=1PSU, 2=2PSUs, ...
R Chip Generation R – SwitchX®
S – SwitchX®-2
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
11
1Installation
Installation and initialization of the chassis is a simple process requiring attention to the
normal mechanical, power, and thermal precautions for rack-mounted equipment. Your
chassis comes only with the power supplies and fans pre-installed. The rest of the open-
ings are populated with blanks. All of the leafs, sp
ines, and management modules come
shipped in a separate package.
The chassis requires initial configuration
to get the chassis and Fabric management up
and running through remote management. See the Installation Guide that is packed in the
box for the instructions to make the initial configuration.
1.1 Installation Safety Warnings
These safety warnings are in English. For French, German, Spanish, Russian, and Roma-
nian see the Appendixes.
1. Installation Instructions
2. Bodily Injury Due to Weight
3. Heavy Equipment
This chassis can be installed in standard 19” racks that have depths between 65cm and
80cm between the vertical supports of the rack.
This unit is intended for installation in a Restricted Access Location. A restricted
access area can be accessed only through the use of a special tool, lock and key, or
other means of security.
Read all installation instructions before connecting the equipment to the power source.
Use enough people to safely lift this product.
This equipment is very heavy and should be moved using a mechanical lift to avoid
injuries.
<40 lbs
<18 kgs
40 - 70 lbs
18 - 32 kgs
70 - 121 lbs
32 - 55 kgs
>121 lbs
>55 kgs
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
12
4. Installation in Restricted Access Location
5. Risk of Electric Shock!
6. Over-temperature
7. Stacking the Chassis
8. Redundant Power Supply Connection - Electrical Hazard
9. Double Pole/Neutral Fusing
10. Multiple Power Inlets ,
This unit is intended for installation in a Restricted Access Location.
Risk of Electric Shock!
With the fan module removed power pins are accessible within the module cavity.
DO NOT insert tools or body parts into the fan module cavity.
This equipment should not be operated in an area with an ambient temperature exceed-
ing the maximum recommended: 45°C (113°F). Moreover, to guarantee proper air
flow, allow at least 8cm (3 inches) of clearance around the ventilation openings.
The chassis should not be stacked on any other equipment. If the chassis falls, it can
cause bodily injury and equipment damage.
This product includes a redundant power or a blank in its place. In case of a blank
power supply, do not operate the product with the blank cover removed or not securely
fastened.
This system has double pole/neutral fusing. Remove all power cords before opening
the cover of this product or touching any internal parts.
Risk of electric shock and energy hazard.
The PSUs are all independent.
Disconnect all power supplies to ensure a powered down state inside of the switch
platform.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
13
11. During Lightning - Electrical Hazard
12. Copper InfiniBand Cable Connecting/Disconnecting
13. Rack Mounting and Servicing
14. Equipment Installation
15. Equipment Disposal
16. Local and National Electrical Codes
17. Installation Codes
During periods of lightning activity, do not work on the equipment or connect or dis-
connect cables.
Copper InfiniBand cables are heavy and not flexible, as such they should be carefully
attached to or detached from the connectors. Refer to the cable manufacturer for spe-
cial warnings/instructions.
When this product is mounted or serviced in a rack, special precautions must be taken
to ensure that the system remains stable. In general you should fill the rack with equip-
ment starting from the bottom to the top.
This equipment should be installed, replaced, and/or serviced only by trained and qual-
ified personnel.
Disposal of this equipment should be in accordance to all national laws and regula-
tions.
This equipment should be installed in compliance with local and national electrical
codes.
This device must be installed according to the latest version of the country
national electrical codes. For North America, equipment must be installed in
accordance to the applicable requirements in the US National Electrical Code
and the Canadian Electrical Code.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
14
18. Battery Replacement
19. UL Listed and CSA Certified Power Supply Cord
20. High Leakage Current
21. Add GND connection information
22. Installation codes
23. Interconnection Of Units
Warning: Replace only with UL Recognized battery, certified for maximum
abnormal charging current not less than 4mA
There is a risk of explosion should the battery be replaced with a battery of an
incorrect type.
Dispose of used batteries according to the instructions.
For North American power connection, select a power supply cord that is UL Listed
and CSA Certified, 3 - conductor, [16 AWG], terminated with a molded plug rated at
125 V, [13 A], with a minimum length of 1.5m [six feet] but no longer than 4.5m.
For European connection, select a power supply cord that is internationally
harmonized and marked “<HAR>”, 3 - conductor, minimum 1.0 mm
2
wire,
rated at 300 V, with a PVC insulated jacket. The cord must have a molded plug
rated at 250 V, 10 A.
Warning: High leakage current; Earth connection essential before connecting supply.
Before connecting this device to the power line, the protective earth terminal screws of
this device must be connected to the protective earth in the building installation.
(GND Connection Information):
The building installation shall provide a means for a connection to protective earth;
and the equipment shall be permanently connected to that by a service person.
A SERVICE PERSON shall check whether or not the socket - outlet from which the
equipment is to be powered provides a connection to the building protective earth. If
not, the SERVICE PERSON shall arrange for the installation of a PROTECTIVE
EARTHING CONDUCTOR from the separate protective earthing terminal to the pro-
tective earth wire in the building. The equipment shall be installed in area where equi-
potential bonding exists ((such as a telecommunication centre or a dedicated computer
room).
This device must be installed according to the latest version of the country national
electrical codes. For North America, equipment must be installed in accordance to the
applicable requirements in the US National Electrical Code and the Canadian Electri-
cal Code.
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL
certified type DP-1 or DP-2. (Note- when residing in non LPS circuit)
Overcurrent Protection: A readily accessible Listed branch circuit overcurrent
protective device rated 20 A must be incorporated in the building wiring.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
15
24. Hazardous Radiation Exposure
25. Proper Enclosure
26. Do Not Use the Switch as a Shelf or Work Space
27. WEEE Directive
28. Country of Norway Power Restrictions
1.2 Environmental and Safety Recommendations
The following are Mellanox recommendations.
Caution – Use of controls or adjustment or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
CLASS 1 LASER PRODUCT and reference to the most recent laser standards
IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+
A2:2001
A suitable electrical, mechanical and fire enclosure shall be provided by the end prod-
uct manufacturer and or the end user.
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The
rails are not intended for sliding the unit away from the rack. It is for permanent instal-
lation at final resting place only, not used for service and maintenance
According to the WEEE Directive 2002/96/EC, all waste electrical and electronic
equipment (EEE) should be collected separately and not disposed of with regular
household waste.
Dispose of this product and all of its parts in a responsible and environmentally
friendly way.
This unit is intended for connection to a TN power system and an IT power system of
Norway only.
Recommended ambient temperature in the System room is 20
o
± 5
o
C.
Recommended humidity range is 40% ± 15% without condensing.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
16
1.3 Chassis Package Contents
The package includes:
1 box containing
installation kit parts
cable management system
•power cords
1 shelf
1 chassis with the following modules inst
alled:
•4 fans
4 PSUs
If you are not using a mechanical lift to install the chass
is, reduce the weight of the chas-
sis by removing all of the power supply units,
and fan units, and put aside for reinstalla-
tion after the chassis is installed in the rack.
1 installation guide
1 box containing various other parts
Inside the single box is 3 smaller boxes.
1 installation kit box
1 box containing 4 power cords 250v 15a 2.0M, C14 to C13, USA UL Standard
It is highly recommended that the installation sites be as isolated as possible from all
sources of radio transmissions and electrical interference.
It is highly recommended that the installation site building be equipped with a light-
ning rod.
It is highly recommended that the installation site be equipped with smoke detectors
and a fire alarm warning system.
The system requires a KVA rated UPS system. It is recommended that a UPS system
be installed to protect the equipment in the event of unexpected power failure.
Make sure that the outlets and circuits will not be overloaded. Spread out the load over
at least two or three circuits or use a 3 phase circuit.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
17
1 cable management kit
Before you install your new SX6512 series chassis, unpack the system and check to
make sure that all the parts have been sent, check this against the parts list. Check the
parts for visible damage that may have occurred during shipping.
1.4 Leaf Package Contents
The leafs are ordered by the customer and are shipped 4 to a box. The customer will
receive as many boxes as needed to fill the order.
1.5 Spine Package Contents
The spines are shipped 3 to a box. The customer will receive as many boxes as needed to
fill the chassis with a full complement of spines.
1.6 Management Package Contents
The package includes:
all of the management modules ordered by the customer
1 RJ45 to DB9 harness for each management module received
1.7 Physical Installation
The switch platform uses 10U of rack space in a standard 19” rack, 9U for the chassis
and 1U for the shelf. The switch ships from the factory with mounting holes on the spine
side. There are upper brackets to connect the leaf side to the rack near the top of the chas-
If anything is damaged or missing, contact your customer representative immediately.
The rack mounting holes conform to the EIA-310 standard for 19-inch racks. Guaran-
tee proper ventilation, by leaving 8cm (3”) of space to the front and rear of the switch.
This will ensure proper air flow through the chassis. This is crucial for maintaining
good airflow at ambient temperature. In particular, route cables such that they do not
impede the air into or out of the chassis.
Insert the bottom spine board first.
Warning: This equipment is very heavy. Safety is the first concern. Make sure that
adequate manpower and proper equipment is used for transporting and moving the
chassis.
The fully loaded chassis weighs:
120 kg (265 LBS) full configuration
48 KG (105 LBS) empty configuration
83.94kg (185 LBS) shipped configuration
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
18
sis. The weight of the switch is supported from underneath the unit by the shelf.
This chassis can be installed in standard 19” racks tha
t have between 65cm and 80cm
between the vertical supports of the rack. Make sure that a fully populated rack including
cables will have sufficient air flow for cooling.
1.7.1 ESD Connection
Before starting any procedure on the SX6512 switch system:
1. Put an ESD prevention wrist strap on your wrist, and
make sure there is good contact
between your body and the strap.
2. Plug the other end of the wrist strap to a valid
ground. Make sure that this is a tight
fit.
1.7.1.1
Installation ProcedureRequirements
You will need:
Choose a rack which is able to support the mechanical and environmental characteris-
tics of a fully populated switch chassis.
#2 phillips screwdriver #3 phillips screwdriver
a grounding lug ground wire to properly ground the chassis
The installation will be much easier with a power screwdriver.
It is recommended to use AWG6 or 4mm diameter wire for grounding purposes.
It is recommended to have at least two people for the duration of the installation proce-
dure. Use a mechanical lift to raise this chassis. If not, use enough manpower to ensure
the safety and wellbeing of all of the people involved in the installation.
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
19
1.7.1.2 Installation and Cable Management Kit Parts
Parts for installing the shelf
Parts for installing the chassis
Parts for installing the filler panel
Parts for installing the cable manager
You will need 10 U of space in the rack. Nine U for the chassis and one
U for the shelf.
Figure 1: Shelf Installation Kit Parts
•1 shelf 8 M6 bolts for the caged nuts
4 caged nuts 2 Shelf rail slides
4 lock washers 2 long 2 hole flat washers
2 chassis rail slides 4 handles
8 M-5 pan head bolts 8 allen head screws
2 flat 4 hole metal spacers 1 allen wrench
8 lock washers 4 lock nuts for handles (These nuts are not to be used)
8 caged nuts for the faceplate 8 M6 bolts for the caged nuts, 8 for the faceplate
1 Bottom filler panel 2 M6 bolts
2 caged nuts M6
1 RH cable holder 1 LH cable holder
12 caged nuts M6 12 M6 bolts
6 cable holder shelves
Shelf
Rail
Rail Slide
Angled
Bracket
M6 X 12 bolts, caged nuts and
split lock washers
M6 X 16
InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
20
Figure 2: Chassis Installation Parts
1.7.1.3 Container Mishandling
The container has shock and tilt stickers applied. These will turn
red if the container has
been mishandled or roughly handled. Upon receipt of the container look for and inspect
the shock and tilt stickers to confirm that they have not tripped. If one or more are red
notify the shipper and Mellanox. This on its own does not indicate damage to the con-
tents. But, be sure to carefully inspect
the contents if any of the shock and tilt stickers
have tripped.
Rail Slide
Screws for
the handles
M-5 Pan head
screws and
lock washers
4 hole Washer
Handles
Caged nuts
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118

Mellanox Technologies MSX6512-4R Hardware Installation Manual

Tip
Hardware Installation Manual
Acest manual este potrivit și pentru

în alte limbi