7
ENG
USAGE WITH FLUE
USAGE WITHOUT FLUE
IMPORTANT NOTICE
FILTER CHANGE (WASHING)
There is an air exit on your aspirator. Flue connection will be made from this air exit. A flue adapter suitable
for 120 mm diameter is supplied with the aspirator. It is recommended to use spiral pipe with a diameter of
120 mm in the flue pipe. Pipe connection should be as short as possible and with least number of elbows for
efficient operation of your aspirator.
Closet shelves or cabinet ceilings that may prevent the outlet pipe should be cut in the same size to ensure
air circulation in the kitchen. The air sucked by the aspirator is given into the kitchen in usage without flue. A
culvert should be installed to the mouth of the pipe on the facade. Replace your carbon filter every 3 months in
average.
1. The distance between the bottom surface of your aspirator and the upper surface of electric ovens should
be 65 cm stove while the distance should be 75 cm stove between the bottom surface of your aspirator
and the upper surface of ovens using gas or mixed fuels . Otherwise, the product will be definitely out of
warranty!
2. Place the flue exit in the same diameter (without making it smaller).
3. Do not operate your aspirator without filter.
4. Do not change the filter while your aspirator is running.
5. Operate your aspirator while you operate your stove.
6. Do not open your aspirator when you feel a gas leak.
7. Wipe your aspirator with cloth soaked in warm water with detergent and dry.
8. You may use the aluminum filter by washing at least once a month
9. Replace the oil filter with synthetic fiber every 2 months
10. Replace the imported carbon filter every 3 months in use without flue.
• Remove the cassette filter by pushing the latches inside.
• Place one side of the filter into the house and secure the filter by pressing inside and leaving the latch of the
other side.
6. If the supply cord is damaged, this cord must be replaced by the manufacturer or its service agent or
equally qualified personnel to prevent a dangerous situation.
7. Flaming foods should not be cooked under the device. They may cause fire.
8. The air discharge pipe should be aluminum. The air discharge pipe should have a length of 120 mm. and
louver culvert should be assembled to the outlet at the exterior without fail. Place the pipe for flue outlet
outside never narrowing the diameter of the pipe (120 mm)
9. Do not use non-fire-resistant filtering materials (such as paper) on the filter.
10. Turn the unit off and take the plug from the socket prior to the maintenance process.
11. Use max 6 amp fuse for your safety.
NOTE
Your aspirator is produced to work with and without flue connection.