Tellur TLL331291 Manual de utilizare

Tip
Manual de utilizare
Wi-Fi Gas Sensor
User Manual
TLL331291
For other languages, please visit smart.tellur.com
Thank you for choosing Tellur!
To ensure an optimum performance and safety, please read this user manual
carefully before using the product. Keep this user manual safe for future
references.
WHAT’S IN THE BOX
1 x Tellur Gas sensor
1 x DC12V adapter
1 x 3M tape
2 x Screws
2 x Screw taps
1 x User manual
Tellur Gas sensor
Screws Screw taps
DC 12V adapter 3M tape
User manual
1.PRODUCT OVERVIEW
Increase your sense of security with Tellur's WiFi Smart Gas Sensor. Having
an unique air flow design, the core sensor is protected from vapors, oil spills
or smoke, ensuring its continuous operation.
When it detects gas, the sensor alerts you through an acoustic alarm, a light
indicator and a push notification is sent to your smartphone.
The WiFi Smart Gas Sensor is easily installed and works on DC 12V (AC 220V
adapter included).
The sensor integrates perfectly in the Smart Home ecosystem and allows
you to check its working status and history records by simply accessing the
Tellur Smart app from your smartphone. Also from the app you can
remotely mute the alarm or make the sensor to perform a self-check just to
be sure the device is operating effectively.
2.PRODUCT FEATURES
Detects gas leakage and triggers the alarm.
Multiple warnings: light indicator, high-decibel acoustic alarm & push
notification
Compatible with Tellur Smart app, perfectly integrated in the Smart Home
ecosystem
Remote control: mute & self-test
Easy to install & use
Working on 802.11 b/g/n 2.4GHz wireless network (no hub required)
Wi-Fi network configuration with EZ (Smart Config) and AP (Access Point)
mode
Share the device with your family
Mounting with adhesive tape or screw
Quick guide:
• Make sure the WiFi network is a 802.11 b/g/n 2.4GHz band and internet is
available.
• Download the app from Apple store or Google Play;
• Register an account in the app and login with your email address;
• Setup the device WiFi connection;
• Mount the device on specified location;
• Test and check the working state of the device and app.
3.PRODUCT DIAGRAM
LED indicator / Button
Back side of the sensor
after removing the bracket
Adapter socket
3.LED INDICATORS & SOUND MEANING
Red LED flashing
Red, Green and Yellow
LED flashing alternately
Green LED ON
Yellow LED ON
Buzzer ON
Buzzer OFF
Buzzer OFF
Buzzer ON
Gas leaking alarm
The sensor is initializing
Normal working status
Fault
4.PRODUCT SPECIFICATIONS
Power supply: DC 12V (AC 220V adapter included)
Alarm level: 70dB @ 1 meter
Push notifications: Yes
History record: Yes
Self-test: Yes
Gas type detection: Natural gas (CH4)
Tolerated concentration: ±5% LEL (Lower Explosive Limit)
Alarm concentration: 8%LEL, tolerance ±3% LEL
Alarm response time: <30 seconds
WiFi standard: IEEE 802.11b/g/n
Supported WiFi network: 2.4GHz
Color: White
Housing material: PC + ABS
Installation method: Screws or 3M tape
Operating temperature: -10°C - +55°C
Operating humidity: 5% - 95% RH
Product dimensions: 66 x 66 x 29mm
Product weight: 62 gr
Set up router
This device only supports 2.4GHz frequency band router, does not support
5GHz frequency band router, please set the relevant parameters of the
router before WiFi configuration, WiFi passwords do not include special
characters such as ~!@#$%^&*(). When the device is configured in WiFi,
the mobile phone and device are as close as to the router, which can speed
up the configuration of the device.
5. INSTALL APP AND REGISTER AN ACCOUNT
Download the Tellur Smart App for both iOS and Android OS.
Scan the QR code to download Tellur Smart App
Android
IOS Download App(IOS&android)
6. ADD AND REMOVE DEVICE IN YOUR APP ACCOUNT
6.1 Open the app and login, Click Add Devices > Security and Sensor >
Gas Detector (Wi-Fi) to start the device adding.
6.2 Press the device button for 5 seconds to enter the Wi-Fi configuration
state (fast blinking in EZ mode or slow blinking in AP mode).
6.3 Input the Wi-Fi SSID and password of the Wi-Fi network that the device
is going to work with, then waiting around 30 seconds for the Wi-Fi
configuration finished until a device is successfully added;
6.4 Change the device name and share it within APP account as you want.
6.5 Click the device just added to launch the device state UI to check the
state, battery level, record history and the APP notification setting.
Note:
*Make sure the device and APP work in same Wi-Fi configuration mode, both
in EZ mode or in AP mode.
*In some case that the EZ mode is not working Wi-Fi network, AP mode is the
only option.
• EZ mode:
make sure your APP is internet available and device and APP both work in
EZ mode. Then input the Wi-Fi network password to finish the device
adding. If you want to change the Wi-Fi network, please check the “Change
network” in APP;
• AP mode:
Click AP Mode, make sure your APP is internet available and device and
APP both work in AP mode. Confirm to input the SSID and Password of
Wi-Fi network, then select the Device AP name with Tellur Smart App in
Wi-Fi list then back to App to finish the device adding.
After the device is successfully added to APP account, the LED will turn
off. Using the methods mentioned in LED indicator to check the device is
successfully added or not. If not, please repeat the Device adding again.
6.6 Remove device
1) Click “Remove Device” to remove this device from your account; click
“Restore manufacturer Defaults” to remove the device from your account
and clear the history record in cloud.
2) After remove device or Restore manufacturer defaults from the APP,
repeating the Device add steps to your account;
7.PRODUCT INSTALLATION
•The product is only for indoor ceiling installation;
•The Gas Sensor is suitable for natural gas detection;
•It is recommended to mount it in a location directly above the gas source
Ceiling
Ground
Gas stove
Gas sensor >1.5m<3m
900
*The area marked with grey
is recommended for installing the sensor
Functionality:
1.Turn on the power of the sensor. If the yellow LED flashes once and the
buzzer emits a short sound, it means that the sensor is in preparing state. If
red, green, and yellow LED flashed alternately and the green LED remains
on, the sensor is working normally.
2.In normal working mode, you can press the button to perform a self-test of
the sensor. The buzzer will emit a short sound and the red, green, and yellow
will flash in sequence until the green light will remain permanently on
(returning to normal working mode).
3.If a gas leakage is detected, the red LED will flash, the buzzer will emit a
repeated sound and you will receive an alarm notification on your
smartphone. The alarm will stop if there is no more gas detected.
4.If the yellow LED is always on and the buzzer emits a continuous sound, the
sensor is faulty.
•Fix the bracket to the wall with screws or 3M tape, Fix the sensor into the
bracket by rotating it clockwise. If you use 3M tape, please make sure the
wall surface is firm, smooth, and clean.
•Screw installation is recommended. The user is responsible for any
accidents and safety incidents caused by poor installation.
5.If fault is detected, turn off and than again on the power. The sensor will
start a self-test. If the fault alarm still persists, remove the sensor and repair
it or replace with a new one.
Important notes
-If the mounting location is unconventional (different from the recommended
installation in the diagram), check carefully for the best position that ensures
an effective monitoring of potential gas leakage.
-In case of house decoration, the gas released by solvents or paint can
damage the sensor and can cause false alarms. When decorating try to
protect the gas sensor from dust and vapors of any kind. Open the doors and
windows to maintain a good ventilation and, if possible, remove the sensor
temporarily.
-Do not install the sensor too close to the gas stove, heating and smoke can
affect the normal working and sensitivity of the sensor.
-Avoid long-term exposure to liquid vapors and soot.
-Avoid liquid spills or high humidity locations.
-Avoid installation in high or low temperature environments (not higher than
55°C or lower than -10°C)
-Avoid mounting the sensor in an environment with the following gases:
silicone vapor, formaldehyde, toluene, acetic acid, and hydrogen sulfide.
These are mainly produced from home decoration, decorative materials,
adhesives, paint, hair gel, silicone, etc. These gases can cause irreparable
damage to the sensor, leading to false alarms or failure. In addition, high
concentration of alcohol vapors can lead to a false alarm and can decrease
the long term sensitivity of the sensor.
-The sensor will send an audible, visual and push notification when gas is
detected.
-Do not test the sensor with open flame to avoid damaging the product.
-If alarm is sent during the test, it warns you of potential danger and needs
immediate attention. Never ignore any alarm, which may lead to casualties
or property damage.
-If the sensor fails self-test, please refer to “Troubleshooting” part of the
manual. If the fault can not be fixed, the product should be replaced
immediately.
Daily maintenance
-Test the sensor periodically.
-Keep the sensor clean and without dust. You can clean it with a vacuum
cleaner and a soft fabric material or a soft brush.
-Do not let solvents or cleaning agents inside the gas sensor. It can cause
damages to the sensor. After cleaning, perform a test of the sensor.
-Do not paint the sensor, it can affect the normal operation of the product.
8.TROUBLESHOOTING
-If the sensor is not reacting, check if the sensor is properly installed and is
powered correctly.
-Re-position the sensor if there are many false alarms.
-Try to clean the sensor if there are many false alarms.
9.WARNING
-In case of gas leakage alarm, take all appropriate measures:
oClose the gas pipe valve.
oOpen the windows and doors.
oExtinguish possible fires sources, such fireworks, lighters, matches.
oDo not turn on any electrical appliances.
oOnly if safe to do, check the reason of gas leakage and promptly notify the
relevant departments or professionals to deal with it.
-Do not leave the product in extreme high temperature environment.
-Do not disassemble the sensor, it will cause the warranty to be lost.
-Keep out of reach of children.
Disposal and recycling information
The crossed-out wheeled-bin symbol on your product, battery, literature or
packaging reminds you that all electronic products and batteries must be
taken to separate waste collection points at the end of their working lives;
they must not be disposed of in the normal waste stream with household
garbage. It is the responsibility of the user to dispose of the equipment
using a designated collection point or service for separate recycling of
waste electrical and electronic equipment (WEEE) and batteries according
to local laws. Proper collection and recycling of your equipment helps
ensure EEE waste is recycled in a manner that conserves valuable
materials and protects human health and the environment, improper
handling, accidental breakage, damage, and/or improper recycling at the
end of its life may be harmful for health and environment.
For other langauges please scan th QR code
Pentru manuale in alte limbi vă rugăm să scanați codul QR
Para otros idiomas, escanee el código QR
Pour les autres langages, veuillez scanner le code QR
Für andere Sprachen scannen Sie bitte den QR-Code
Per altre lingue, eseguire la scansione del codice QR
www.tellur.com/manual-tll331291
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Tellur TLL331291 Manual de utilizare

Tip
Manual de utilizare

în alte limbi