17
E. Before using
Check up whether the exhaust hose
has been mounted properly.
Cautions for cooling and
dehumidifying operations:
-When using functions on cooling and
dehumidifying, keep an interval of at
least 3 minutes between each
POWER.
-Power supply meets the
requirements.
-The socket is for AC use.
-Do not share one socket with other
appliances.
-Power supply is
AC220-240V, 50Hz
2. Cooling operation
-Press the “Mode” button till the
“Cool” icon appears.
-Press the “ ”or“ ”button to select
a desired room temperature.
(16°C -31°C )
-Press the “Fan Speed” button to
select wind speed.
3. Dehumidifying operation
Press the “Mode” button till the
“Dehumidify” icon appears .
-Automatically set the selected
temperature to current room
temperature minus 2°C .
-Automatically set the fan motor to
LOW wind speed.
4. Fan operation
-Press the “Mode” button till the “Fan”
icon appears.
-Press the “Fan Speed” button to
select wind speed.
5. Heating operation (this function is
not available for a cold-single unit)
-Press the “Mode” button till the
“Heat” icon appears.
-Press the “ ”or“ ” button to select
a desired room temperature.
(16°C-31°C)
-Press the “Fan Speed” button to
select wind speed.
6. Timer operation
Timer ON setting:
-When the air-conditioner is OFF,
press the “Timer” button and select a
desired ON time through the
temperature and time setting buttons.
-“Preset ON Time” is displayed on the
operation panel.
-ON time can be regulated at any time
in 0-24 hours.
Timer OFF setting
-When the air-conditioner ON, press
“Timer” button and select a desired
OFF time through the temperature
and time setting buttons.
-“Preset OFF Time” is displayed on
the operation panel.
-OFF time can be regulated at any
time in 0-24 hours.
7. Continuous Drainage
Internal Tank Water Full Alarm
Function
The inner water tank in the airconditioner
has one water level safety
switches, it controls the water level.
When water level reaches an
anticipated height, the water full
indicator lights up. When the water is
full, please remove the rubber
blockage from the drainage hole at
the bottom of unit, and drain all water
outside.
Continuous Drainage
-When you plan to leave this unit
unused for a long time, please
remove the rubber blockage from the
drainage hole at the bottom of unit,
and drain all water outside.
-You can use the continuous drainage
with a drainage hose connected to the
bottom drain hole, when the unit
working at the HEAT mode.
-The continuous drainage is not need
to be applied when the unit working at
the COOL or DEHUMIDIFY mode.
The unit can evaporate the
condensate water automatically by
the splash motor. Make sure the
drainage holes are stemmed well.
-If water splash motor is damaged,
continuous drainage can be used.
To connect the drain hose to the
bottom drain hole, the unit can also
work well.
-If splash motor is damaged,
intermittent drainage can also be
used. Under this condition, when the
water full indicator lights up, please
connect a drain hose to the bottom
drainage hole, then all the water in the
water tank will be drained outside. The
unit can also work well.
8. WIFI function
- Long press the SPEED button for
5s, enter the WIFI factory set up
mode;
- The unit is connected with WIFI If
the WIFI indicator is on, other wise is
not connected. When the WIFI
indicator ashing slowly, the unit is at
the WIFI set up mode, if ashing
quickly, the unit is connected with
WIFI;
- You can realize all the air
conditioner functions by the mobile
phone APP with the WIFI connected.
Maintenance
Clean the condensor with Wood’s
cleaning
detergent. Read more about how
to clean your unit at woods.se Clean the
unit with a soft moist cloth. Do not use
solvents or strong cleaners as this might
damage the surface of the unit.
Service
If the Air Conditioner requires servicing,
you must rst contact your local retailer.
Proof of purchase is required for all
warranty claims.
Storage instructions
End of Season Storage
1) Screw off he drain cover and pull out
the stopper to drain condensate water
completely.
2) Keep unit running in fan mode for half
day to dry inside of unit completely to
prevent from going moldy.
3) Turn off he unit, pull out plug then
wrap the power cord around the wire-
winding pillar, insert the plug into the
universal xing hole at the back panel
of the unit, install the water stopper and
drain cover.
4) Remove the heat exhaust hose
assembly,
clean and keep it properly.
Notes:
Hold the exhaust hose assembly with
both hands when removal.
Push the fasteners aside on exhaust air
outlet using your thumbs, then pull out
exhaust hose assembly.
5) Pack the air-conditioner properly with
soft plastic bag and put it in dry place
with appropriate dust-proof measures,
and keep the unit away from children.
6) Take out the batteries from the remote
control and keep it properly.
Note:
Assure the unit is stored in a dry place.
All accessories of the unit shall be
protected
together properly
Power cord holder and universal socket
can well protect the power cord.
High position of exhaust air outlet, easy
assembly and venting quickly.
Intelligent, environmental-friendly and
energy saving with self-evaporative
cooling system.
24-hour Timer function, unique on/o
reminding music.
3-minute delay re-starting protection to
compressor and other multiple protection
functions.
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS