Njoy Balder 1500 Manual de utilizare

Categorie
Surse de alimentare neîntreruptibile (UPS-uri)
Tip
Manual de utilizare
Balder Series User Manual
Manual de utilizare
PWUP-OL150BA-AZ01B
PWUP-OL300BA-AZ01B
v. 1
Before using this product, carefully read all product documentation and retain it for future reference.
02 03
ON/MUTE
SELECT
OFF/ENTER
UPS Unit
User Manual
Warranty card
USB Cable
Rack mounting holders
Tower mounting stand
Screws
Package Contents
Product Overview
1
2
Front View 1500/3000
LCD panel
Function buttons
The following models belong to the Balder Series:
Balder 1500
Balder 3000
1500VA
3000VA
Thank you for purchasing our products!
Please read this manual before using the product.
Focusing on quality at competitive prices, nJoy designs
consumer products for a better and enjoyable way into
the digital world.
This UPS will protect your electronic equipment from physical
damage and will provide emergency battery backup power to
prevent data loss in the event of power problems.
English
Română
04 05
LCD Panel
1. Input/output/battery voltage
info
2. UPS status
3. Load level
4. Battery level
5. Warning and fault info
1. Programable Output
receptacles: connect to non-
critical mission loads (max
10A)
2. General Output receptacles:
connect to critical mission
loads (max 10A)
3. AC input
4. Network/Fax/Modem surge
protection
5. USB communication port
6. RS-232 communication port
7. SNMP intelligent slot
8. Emergency power off
function connector (EPO)
9. Connector for battery pack
1. Programable Output
receptacles: connect to non-
critical mission loads (max
10A)
2. General Output receptacles:
connect to critical mission
loads (max 10A)
3. AC input
4. Network/Fax/Modem surge
protection
5. USB communication port
6. RS-232 communication port
7. SNMP intelligent slot
8. Emergency power off function
connector (EPO)
9. Connector for battery pack
3
1
5
2
4
Back View
Balder 1500
Balder 3000
USB
EPO
OUT
RS232
IN
NETWORK/FAX/MODEM
INTELLIGENT SLOT
PROGRAMMABLE
OUTLETS (P1)
OUTPUT
INPUT
10A max.
English
Română
USB
EPO
OUT
RS232
IN
NETWORK/FAX/MODEM
INTELLIGENT
SLOT
PROGRAMMABLE
OUTLETS (P1)
OUTPUT
OUTPUT
INPUT
Please comply with all warnings and operating instructions in this
manual strictly. Save this manual properly and carefully read the
following instructions before installing the unit. Do not operate this
unit before reading through all safety information and operating
instructions carefully:
Important Safety Warnings3
Transportation
Please transport the UPS system only in the original package to
protect against shock and impact.
Preparation
Condensation may occur if the UPS system is moved directly from
cold to warm environment. The UPS system must be absolutely
dry before being installed. Please allow at least two hours for the
UPS system to acclimate to the environment.
Do not install the UPS system near water or in moist environments.
6 7 1 38
5 9 2
4
4713
8
8 26 9
06 07
English
Română
Do not install the UPS system where it would be exposed to direct
sunlight or near heat sources.
Do not block ventilation holes in the UPS housing.
Installation
Do not connect appliances or devices which would overload the
UPS system (e.g. laser printers) to the UPS output sockets.
Place cables in such a way that no one can step on or trip over
them.
Do not connect domestic appliances such as hair dryers to UPS
output sockets.
The UPS can be operated by any individuals with no previous
experience.
Connect the UPS system only to an earthed shockproof outlet
which must be easily accessible and close to the UPS system.
Please use only VDE-tested, CE-marked mains cable (e.g. the
mains cable of your computer) to connect the UPS system to the
building wiring outlet (shockproof outlet).
Please use only VDE-tested, CE-marked power cables to connect
the loads to the UPS system.
When installing the equipment, it should ensure that the sum of
the leakage current of the UPS and the connected devices does not
exceed 3.5mA.
Operation
Do not disconnect the mains cable on the UPS system or
the building wiring outlet (shockproof socket outlet) during
operations since this would cancel the protective earthing of the
UPS system and of all connected loads.
The UPS system features its own, internal current source
(batteries). The UPS output sockets or output terminals block may
be electrically live even if the UPS system is not connected to the
building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/
Enter button to disconnect the mains.
Prevent fluids or other foreign objects from entering the inside of
the UPS system.
Maintenance, service and faults
The UPS system operates with hazardous voltages. Repairs may
be carried out only by qualified maintenance personnel.
Caution - risk of electric shock. Even after the unit is disconnected
from the mains (building wiring outlet), components inside the
UPS system are still connected to the battery and electrically live
and dangerous.
Before carrying out any kind of service and/or maintenance,
disconnect the batteries and verify that no current is present and
no hazardous voltage exists in the terminals of high capability
capacitor such as BUS-capacitors.
Only persons are adequately familiar with batteries and with
the required precautionary measures may replace batteries and
supervise operations. Unauthorized persons must be kept well
away from the batteries.
Caution - risk of electric shock. The battery circuit is not isolated
from the input voltage. Hazardous voltages may occur between
the battery terminals and the ground. Before touching, please
verify that no voltage is present!
Batteries may cause electric shock and have a high short-circuit
current. Please take the precautionary measures specified in this
manual and any other measures necessary when working with
batteries: remove wristwatches, rings and other metal objects, use
only tools with insulated grips and handles.
When changing batteries, install the same number and same type
of batteries.
Do not attempt to dispose of batteries by burning them. This could
cause battery explosion.
Do not open or destroy batteries. Escaping electrolyte can cause
injury to the skin and eyes. It may be toxic.
Please replace the fuse only with the same type and amperage in
order to avoid fire hazards.
Do not dismantle the UPS system.
08 09
English
Română
Installation4
The UPS can protect your equipment from all power problems such as
surges, spikes, blackouts, brownouts and line noise. When AC power
is present and the ON/ Mute switch is turned ON, the UPS will provide
pure and stable AC power to the output. The UPS will also charge the
battery in the on-line mode.
The UPS is simple to install and operate. Please read the following
steps before connecting any equipments to this UPS:
NOTE: Before installation, please inspect the unit. Be sure that nothing
inside the package is damaged. Please keep the original package in a safe
place for future use.
Connecting your equipment and first usage4.1
Step 1. Connecting the batteries: For safety consideration, the UPS is
shipped out from factory without connecting the battery wires.
To re-connect battery wires please follow below steps:
Step 2. Connect to External Battery Pack: When connecting external
battery packs, please be sure to connect polarity correctly.
Connect positive pole of battery pack to positive pole of external
battery connector in UPS and negative pole of battery pack to
negative pole of external battery connector in UPS. Polarity
mis-connection will cause UPS internal fault.
Connect only compatible Balder 1500/3000 Battery pack
provided by nJoy. Please read the manual of the UPS and
battery pack and set the UPS battery total capacity in Ah and
the charging current accordingly. The use of another battery
pack may damage the UPS and void the warranty.
I. Remove front panel
II. Connect the AC input and re-
connect battery wires.
III. Put the front panel back to
the unit.
USB
EPO
OUT
RS232
IN
NETWORK/FAX/MODEM
INTELLIGENT SLOT
PROGRAMMABLE
OUTLETS (P1)
OUTPUT
INPUT
10A max.
BATETRY BREAKER
Max, 50A
10 11
First fix the holders of the rack on the UPS.
A. Rack - mount installation
B. Tower installation
Step 3. Mounting the UPS: Balder series UPS can be either displayed on
the desk or mounted in the 19” rack chassis. Please choose your
favourite way to position this UPS.
Then fix the UPS on the rack through the holders
First fix the holders to fit
the UPS.
Then put the UPS in place.
Step 4. UPS input connection: Plug the UPS into a two-pole, three-wire,
grounded receptacle only. Avoid using extension cords.
Step 5. UPS output connection: For socket-type outputs there two
kinds of output: programmable outlets and general outlets.
Please connect non-critical devices to the programmable
outlets and critical devices to the general outlets. During power
failure, you may extend the backup time to critical devices by
setting shorter backup time for non critical devices.
Do NOT plug LASER
PRINTERS into any of
the outlets.
Do NOT plug any SURGE
STRIPS into any of the
outlets.
CAUTION
English
Română
To allow for unattended UPS shutdown/start-up and status monitoring,
connect the communication cable one end to the USB/RS-232 port and
the other to the communication port of your PC. With the monitoring
software installed, you can schedule UPS shutdown/start-up and
monitor UPS status through PC. The UPS is equipped with a slot for
either SNMP or AS400 card. When installing either SNMP or AS400
card in the UPS, it will provide advanced communication and
monitoring options.
Communication port:
USB Port RS-232 Port Intelligent slot
Step 6. Communication connection
NOTE: USB port and RS-232 port can’t work at the same time.
12 13
English
Română
Connect a single modem/phone/fax line into surge-protected “IN”
outlet on the back panel of the UPS unit. Connect from “OUT” outlet to
the equipment with another modem/fax/phone line cable.
Step 8. Disable and enable EPO function: Keep the pin 1 and pin 2
closed for UPS normal operation.
Step 9. Turn on the UPS: Press the ON/Mute button on the front panel
for two seconds to power on the UPS.
It’s in closed status for
UPS normal operation.
To activate EPO
function, remove these
two screws.
Network/Fax/Phone surge port:
Step 7. Network connection
NOTE: The battery charges fully during the first five hours of normal
operation. Do not expect full battery run capability during this initial
charge period.
Step 10. Install software: For optimal computer system protection,
install UPS monitoring software to fully configure UPS
shutdown. Use supplied RS-232 or USB communication cable
to connect RS-232/USB port of UPS and RS-232/USB port of
PC. Install the UPS monitoring software from https://www.
power-software-download.com/viewpower.html to fully
configure UPS shutdown.
Operations5
Button operations5.1
ON/Mute Button
Turn on the UPS: Press and hold ON/Mute button for at least 2
seconds to turn on the UPS.
Mute the alarm: After the UPS is turned on in battery mode,
press and hold this button for at least 5 seconds to disable or
enable the alarm system. But it’s not applied to the situations
when warnings or errors occur.
Up key: Press this button to display previous selection in UPS
setting mode.
Switch to UPS self-test mode: Press ON/Mute buttons
simultaneously for 5 seconds to enter UPS self-testing while in
AC mode, ECO mode, or converter mode.
OFF/Enter Button
Turn off the UPS: Press and hold this button for at least 2
seconds to turn off the UPS. The UPS will be in standby mode
under normal power or transfer to Bypass mode if the Bypass
setting is enabled.
Confirm selection key: Press this button to confirm selection in
UPS settings mode.
ON/MUTE
SELECT
OFF/ENTER
14 15
Select Button
Switch LCD message: Press this button to change the LCD
message for input voltage, input frequency, battery voltage,
output voltage and output frequency.
Settings mode: Press and hold this button for 5 seconds to enter
UPS settings mode when the UPS is in standby mode or bypass
mode.
Down key: Press this button to display next selection in UPS
settings mode.
ON/Mute + Select Button
Switch to bypass mode: When the main power is normal, press
ON/Mute and Select buttons simultaneously for 5 seconds. Then
the UPS will enter to bypass mode. This action will be ineffective
when the input voltage is out of acceptable range.
Select + OFF/Enter Button
Rack or Tower display switch: Press Select and OFF/Enter
buttons simultaneously for 3 seconds. The display change from/
to Rack to/from Tower.
LCD Panel Indicators5.2
Display Function
Backup time information
88
H
M
S
Indicates the estimated backup time.
H: hours, M: minute, S: second.
Configuration and fault information
88
SET Indicates the configuration items, and the con-
figuration items are listed in details in section 5.5.
88
FAULT CODE Indicates the warning and fault codes, and the
codes are listed in details in section 5.7 and 5.8.
Mute operation
Indicates that the UPS alarm is disabled.
Input, Battery, Temperature, Output & Load information
IN BAT OUT
kW
VA
Hz
%
Indicate the input voltage, input frequency, input
current, battery voltage, battery current, battery
capacity, ambient temperature, output voltage,
output frequency, load current and load percent.
k: kilo, W: watt, V: voltage, A: ampere, %: percent, ˚C:
centigrade degree, Hz: frequency
Load information
LOAD
Indicates the load level by 0-24%, 25-49%, 50-
74% and 75-100%.
Indicates overload.
Programmable outlets information
PIndicates that programmable management
outlets are working.
Mode operation information
Indicates the UPS connects to the mains.
Indicates the battery is working.
Indicates charging status.
BYPASS Indicates the bypass circuit is working.
ECO Indicates the ECO mode is enabled.
Indicates the AC to DC circuit is working.
English
Română
16 17
PFC Indicates the PFC circuit is working.
Indicates the inverter circuit is working.
CVCF Indicates the UPS is working in converter mode.
Indicates the output is working.
Battery information
BATT
Indicates the battery level by 0-24%, 25-49%,
50-74%, and 75-100%.
Indicates low battery.
Audible Alarm Indicators5.3
LCD display wordings index5.4
Mode Alarm
Battery Mode Sounding every 5 seconds
Low Battery Sounding every 2 seconds
Overload Sounding every second
Fault Continuously sounding
Bypass Mode Sounding every 10 seconds
Abbreviation Display content Meaning
ENA ENA Enable
DIS d15 Disable
ESC ESC Escape
HLS HLS High loss
LLS LLS Low loss
AO AO Active open
AC AC Active close
EAT EAtEstimated autonomy
time
RAT rAtRunning autonomy
time
SD Sd Shutdown
ON ON ON
OK 0K OK
English
Română
18 19
Parameter 1 Parameter 2
BL bL Battery Low
OL OL Over Load
OI OI Over input current
NC NC Battery No Connect
OC OC Over Charge
SF SF Site wiring fault
EP EP EPO
TP tPTemperature
CH CH Charger
BF bF Battery Fault
BV bv Bypass Out Range
FU FU Bypass frequency
unstable
EE EE EEPROM error
BR bR Battery
Replacement
UPS Settings5.5
1 2
There are two parameters to set up the UPS.
Parameter 1: For program alternatives. Refer to the table below.
Parameter 2: The settings options or values for each program.
Interface Settings
01: Output voltage settings
Parameter 2: Output voltage:
200: presents output voltage is 200Vac
208: present output voltage is 208Vac
220: present output voltage is 220Vac
230: present output voltage is 230Vac
240: present output voltage is 240Vac
NOTE: Derate capacity to 80% when
the output voltage is adjusted to
200VAC/208VAC.
02: Frequency Converter enable/disable
Parameter 2: Enable or disable converter
mode.
You may choose the following two op-
tions:
CF ENA: converter mode enable
CF DIS: converter mode disable (Default)
NOTE: Derate capacity to 80% when
Frequency Converter mode is enabled.
English
Română
20 21
03: Output frequency settings
Parameter 2: You may set the initial fre-
quency on battery mode:
BAT 50: presents output frequency of 50Hz
BAT 60: presents output frequency of 60Hz
If converter mode is enabled, you may
choose the following output frequency:
CF 50: present output frequency is 50Hz
CF 60: present output frequency is 60Hz
04: ECO enable/disable
Parameter 2: Enable or disable ECO
function. You may choose the following
two options:
ENA: ECO mode enable
DIS: ECO mode disable (Default)
05: ECO voltage range setting
Parameter 2: Set the acceptable high
voltage point and low voltage point
for ECO mode by pressing Down key or
Up key.
HLS: High loss voltage in ECO mode in
parameter 2.
The setting range in parameter 3 is from
+7V to +24V of the nominal voltage.
(Default: +12V)
LLS: Low loss voltage in ECO mode in
parameter 2.
The setting range in parameter 3 is from
-7V to -24V of the nominal voltage.
(Default: -12V)
06: Bypass enable/disable when UPS is off
Parameter 2: Enable or disable Bypass
function. You may choose the following
two options:
ENA: Bypass enable
DIS: Bypass disable (Default)
07: Bypass voltage range setting
Parameter 2: Set the acceptable high
voltage point and acceptable low voltage
point for Bypass mode by pressing the
Down key or Up key.
HLS: Bypass high voltage point
230-264: setting the high voltage point
in parameter 3 from 230Vac to 264Vac.
(Default: 264Vac)
LLS: Bypass low voltage point
170-220: setting the low voltage point
in parameter 3 from 170Vac to 220Vac.
(Default: 170Vac)
08: Bypass frequency range setting
Parameter 2: Set the acceptable high
frequency point and acceptable low
frequency point for Bypass mode by
pressing the Down key or Up key.
HLS: Bypass high frequency point
51-55Hz: setting the frequency high
loss point from 51Hz to 55HZ(Default:
53.0Hz).
LLS: Bypass low Frequency point
45-49Hz: setting the frequency low loss
point from 45Hz to 49HZ(Default: 47.0Hz)
09: Programmable outlets enable/disable
Parameter 2: Enable or disable the
programmable outlets function.
You may choose the following two
options:
ENA: Programmable outlets enable
DIS: Programmable outlets disable
(Default)
English
Română
22 23
10: Programmable outlets setting
Parameter 2: Set up backup time limits
for programmable outlets.
0-999: setting the backup time limits in
minutes from 0-999 for programmable
outlets which connect to non-critical
devices on battery mode. (Default: 999).
11: Autonomy limitation setting
Parameter 2: Set up backup time on
battery mode for general outlets.
0-999: setting the backup time in minutes
from 0-999 for general outlets on battery
mode.
DIS: Disable the autonomy limitation
and the backup time will depend on
battery capacity. (Default)
NOTE: When setting as “0”, the backup
time will be only 10 seconds.
12: Battery total AH setting
Parameter 2:Set up the battery total AH
of the UPS.
7-999: : setting the battery total
capacity from 7-999 in AH. Please set
the correct battery total capacity if
external battery bank is connected.
13: Maximum charger current setting
If you use external battery pack please
set the appropriate charging current
based on battery capacity used. Please
use the following table as reference:
Battery capacity(AH) Total charging
current (A)
7~20 2
20~40 4
40~60 6
60~80 8
80~100 10
100~150 12
NOTE: If you connect Battery Pack 2U for
Balder 1500 (PWUP-BP06PBA-AZ01B)
to Balder 1500 you should set maximum
charger current to 4A.
If you connect Battery Pack 2U for Balder
3000 (PWUP-BP12PBA-AZ01B) to Balder
3000 you should set maximum charger
current to 4A.
14: Charger Boost voltage setting
Parameter 2: Set up the charger boost
voltage.
2.25-2.40: setting the charger boost
voltage from 2.25 V/cell to 2.40V/cell.
(Default: 2.36V/cell)
15: Charger Float voltage setting
Parameter 2: Set up the charger float
voltage.
2.20-2.33: setting the charger float
voltage from 2.20 V/cell to 2.33V/cell.
(Default: 2.28V/cell)
16: EPO logic setting
Parameter 2: Set up the EPO function
control logic.
AO: Active Open (Default). When AO is
selected as EPO logic, it will activate
EPO function with Pin 1 and Pin 2 in
open status.
AC: Active Close. When AC is selected as
EPO logic, it will activate EPO function
with Pin 1 and Pin 2 in close status.
English
Română
24 25
17: External output isolation transformer connection
Parameter 2: Allow or disallow
external output isolation transformer
connection.
ENA: If selected, it’s allowed to
connect to an external output isolation
transformer.
DIS: If selected, it’s not allowed to
connect to external output isolation
transformer. (Default)
18: Display setting for autonomy time
Parameter 2: Set up the display setting
for autonomy time
EAT: If EAT is selected, it will display the
remaining autonomy time. (Default)
RAT: If RAT is selected, it will show
accumulated autonomy time so far.
19: Acceptable input voltage range setting
Parameter 2: Set the acceptable high
voltage point and acceptable low
voltage point for input voltage range by
pressing the Down key or Up key.
HLS: Input high voltage point
280/290/300: setting the high voltage
point in parameter 2. (Default: 300Vac)
LLS: Bypass low voltage point
110/120/130/140/150/160: setting
the low voltage point in parameter 2.
(Default: 110Vac)
00: Exit setting
Exit the setting mode.
Operating Mode Description5.6
Operating
mode Description LCD display
Online mode
When the input voltage is
within acceptable range,
UPS will provide pure
and stable AC power to
output. The UPS will also
charge the battery in
online mode.
ECO mode
Energy saving mode:
When the input voltage is
within voltage regulation
range, UPS will bypass
voltage to output for
energy saving. The UPS
will also charge the
battery at ECO mode.
Frequency
Converter
mode
When input frequency
is within 40 Hz to 70
Hz, the UPS can be set
at a constant output
frequency, 50 Hz or 60 Hz.
The UPS will still charge
battery under this mode.
The capacity of the UPS
should be derated to 80%
when Frequency Converter
mode is enabled.
Battery
mode
When the input voltage
is beyond the acceptable
range or power failure,
the UPS will backup
power from battery and
alarm is sounding every 5
seconds.
Bypass
mode
When input voltage is
within acceptable range
but UPS is overload, UPS
will enter bypass mode
or bypass mode can be
set by front panel. Alarm
is sounding every 10
seconds.
English
Română
26 27
Standby
mode
UPS is powered off and
there is no output supply
power, but the UPS still
can charge batteries.
Fault mode
When a fault has
occurred, the ERROR icon
and the fault code will be
displayed.
Faults Reference Code5.7
Warning indicator5.8
Fault event Fault code Icon
Bus start fail 01 -
Bus over 02 -
Bus under 03 -
Inverter soft start fail 11 -
Inverter voltage high 12 -
Inverter voltage Low 13 -
Inverter output short 14 -
Battery voltage too high 27 -
Battery voltage too low 28 -
Charger output short 2A -
Over temperature 41 -
Overload 43
Charger failure 45 -
Over input current 49 -
Warning Icon
(flashing) Code Alarm
Low Battery bL Sounding every 2
seconds
Overload OL Sounding every
second
Over input current OI Sounding 2 beep
every 10 seconds
Battery is not
connected NC Sounding every 2
seconds
Over Charge OC Sounding every 2
seconds
Site wiring fault SF Sounding every 2
seconds
EPO enable EP Sounding every 2
seconds
Over temperature tPSounding every 2
seconds
Charger failure CH Sounding every 2
seconds
Battery fault bF Sounding every 2
seconds
Out of bypass voltage
range BYPASS bv Sounding every 2
seconds
Bypass frequency
unstable FU Sounding every 2
seconds
Battery replacement br Sounding every 2
seconds
EEPROM error EE Sounding every 2
seconds
English
Română
NOTE: “Site Wiring Fault” function can be enabled/disabled via
software. Please check software manual for the details.
28 29
Replacing the battery6
NOTE: This UPS is equipped with internal batteries. When your battery
lifetime is over you can replace them without shutting down the UPS
or connected loads thanks to the hot-swappable battery design.
Replacement is a safe procedure, isolated from electrical hazards.
Consider all warnings, cautions, and notes before replacing the
batteries.
CAUTION
Step 1. Remove front panel. Step 2. Disconnect battery wires.
Step 3. Pull out the battery box by
removing the two screws on the
front panel.
Step 4. Remove the top cover of
battery box and replace the
inside batteries following the
battery kit assembly procedure.
Step 5. After replacing the
batteries, put the battery box
back to original location and
screw it tightly.
Step 6. Re-connect the battery
wires and put the front panel
back to the unit.
English
Română
30 31
Balder 3000
Step 5. Remove adhesive tapes.
Step 7. Put assembled battery
packs on one side of plastic
shells.
Step 8. Cover the other side of
plastic shell as in the below
picture.
Step 6. Connect all battery
terminals by following below
chart.
Battery kit assemly procedure6.1
Balder 1500
Step 1. Remove adhesive tapes. Step 2. Connect all battery
terminals by following below
chart.
Step 3. Put assembled battery
packs on one side of plastic
shells and insert one more defect
battery on the space (without
connecting it).
Step 4. Cover the other side of
plastic shell as in the below
picture.
English
Română
32 33
Troubleshooting7
Problem Possible Cause Solutions
No indication and alarm
even though the main is
normal.
The AC input
power is not
connected well.
Check if input
power cord is
firmly connected
to the mains.
The AC input is
connected to the
UPS output.
Plug the AC input
power cord to the
AC input correctly.
The icon and the
warning code EP are
flashing on LCD display
and alarm is sounding
every second.
EPO function is
activated.
Set the circuit in
closed position
to disable EPO
function.
The icon and the
warning code SF are
flashing on LCD display.
Alarm is sounding every 2
seconds.
Line and neutral
conductors of
UPS input are
reversed.
Rotate mains
power socket by
180˚ and then
connect to UPS
system.
The icon and and
warning code NC are
flashing on LCD display.
Alarm is sounding every 2
seconds.
The external or
internal battery
is incorrectly
connected.
Check if all
batteries are
connected well.
Fault code is shown as 27
on LCD display and alarm
is continuously sounding.
Battery voltage
is too high or the
charger is fault.
Contact service
unit.
Problem Possible Cause Solutions
Fault code is shown as 28
on LCD display and alarm
is continuously sounding.
Battery voltage
is too low or the
charger is fault.
Contact service
unit.
The icon and
the warning code OL are
flashing on LCD display.
Alarm is sounding every
second.
UPS is
overloaded.
Remove excess
loads from UPS
output.
UPS is
overloaded.
Devices
connected to
the UPS are fed
directly by the
electrical network
via the Bypass.
After repetitive
overloads, the
UPS is locked
in the Bypass
mode. Connected
devices are fed
directly by the
mains.
Remove excess
loads from UPS
output first. Then
shut down the
UPS and restart it.
Fault code is shown as 49
on LCD display and alarm
is continuously sounding.
UPS is over input
current.
Remove excess
loads from UPS
output.
Fault code is shown as 43
and the icon is lighting
on LCD display. Alarm is
continuously sounding.
The UPS
shut down
automatically
because of
overload at the
UPS output.
Remove excess
loads from UPS
output and restart
it.
Fault code is shown as 14
on LCD display and alarm
is continuously sounding.
The UPS
shut down
automatically
because short
circuit occurs on
the UPS output.
Check output
wiring and if
connected devices
are in short circuit
status.
English
Română
34 35
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries
with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not
be treated as household waste.
Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural resources.
Problem Possible Cause Solutions
Fault code is shown as 01,
02, 03, 11, 12, 13 and 41 on
LCD display and alarm is
continuously sounding.
A UPS internal
fault has
occurred. There
are two possible
results:
1. The load is still
supplied, but
directly from AC
power via bypass.
2. The load is no
longer supplied
by power.
Contact service
unit.
Battery backup time is
shorter than nominal
value.
Batteries are not
fully charged.
Charge the
batteries for at
least 5 hours
and then check
capacity. If the
problem still
persists, consult
your dealer.
Batteries defect.
Contact your
dealer to replace
the battery or
replace them by
yourself.
Fault code is shown as 2A
on LCD display and alarm
is continuously sounding.
The short circuit
occurs on the
charger output.
Check if
battery wiring
of connected
external pack is
in short circuit
status.
Fault code is shown as 45
on LCD display. At the same
time, alarm is continuously
sounding.
The charger does
not have output
and battery
voltage is less
than 10V/PC.
Contact service
unit.
English
Română
36 37
ON/MUTE
SELECT
OFF/ENTER
Din seria Balder fac parte următoarele modele:
Balder 1500
Balder 3000
1500VA
3000VA
UPS
Manual de utilizare
Certificat de garanție
Cablu USB
Suporți pentru montarea în rack
Suport pentru montarea pe verticală
Șuruburi
Conținutul pachetului
Prezentarea produsului
1
2
Vedere din față 1500/3000
Mulțumim pentru că ați ales produsele noastre!
Vă rugăm citiți cu atenție manualul de utilizare înainte de a pune în
funcțiune acest produs.
Concetrându-ne pe calitate la preţuri competitive,
construim produse pentru consumatori în ideea unei
interacţiuni cât mai plăcute cu lumea digitală.
UPS-ul va protejează echipamentele electronice de daune fizice
și oferă o baterie de rezervă pentru a preveni pierderile de date
în cazul întreruperilor accidentale ale energiei electrice.
Ecran LCD
Butoane cu funcții diferite
38 39
Vedere din spate
English
Română
Ecran LCD
1. Informații despre tensiunea
la intrare/ieșire și despre
baterie
2. Stare UPS
3. Nivel încărcare
4. Nivel baterie
5. Erori și avertismente
1. Prize de ieșire programabile
destinate echipamentelor
non-critice (max 10A)
2. Prize de ieșire programabile
destinate echipamentelor
critice (max 10A)
3. Alimentare AC
4. Priză protecție supratensiune
pentru Rețea / Fax / Modem
5. Port comunicare USB
6. Port comunicare RS-232
7. Slot pentru cardul SNMP
8. Conector pentru funcția EPO
(oprire de urgență)
9. Conector pentru cabinetul de
baterii
1. Prize de ieșire programabile
destinate echipamentelor
non-critice (max 10A)
2. Prize de ieșire programabile
destinate echipamentelor
critice (max 10A)
3. Alimentare AC
4. Priză protecție supratensiune
pentru Rețea / Fax / Modem
5. Port comunicare USB
6. Port comunicare RS-232
7. Slot pentru cardul SNMP
8. Conector pentru funcția EPO
(oprire de urgență)
9. Conector pentru cabinetul de
baterii
Balder 1500
USB
EPO
OUT
RS232
IN
NETWORK/FAX/MODEM
INTELLIGENT SLOT
PROGRAMMABLE
OUTLETS (P1)
OUTPUT
INPUT
10A max.
6 7 1 38
5 9 2
4
Balder 3000
USB
EPO
OUT
RS232
IN
NETWORK/FAX/MODEM
INTELLIGENT
SLOT
PROGRAMMABLE
OUTLETS (P1)
OUTPUT
OUTPUT
INPUT
Vă rugăm să respectați toate avertismentele și instrucțiunile de utilizare
din acest manual. Păstrați acest manual în mod corespunzător și citiți
cu atenție următoarele instrucțiuni înainte de instalarea aparatului. Nu
folosiți această unitate înainte de a citi toate instrucțiunile de siguranță
și de utilizare cu atenție:
Avertizări de siguranță3
4713
8
8 26 9
Transport
Vă rugăm să transportați sistemul UPS numai în ambalajul
original pentru a-l proteja împotriva șocurilor.
Pregătire
Condensul poate apărea dacă sistemul UPS este mutat dintr-un
mediu rece în unul cald. Sistemul UPS trebuie să fie uscat înainte
de a fi instalat. Vă rugăm să alocați cel puțin două ore pentru
ca sistemul UPS să se aclimatizeze cu mediul unde doriți să îl
instalați.
3
1
5
2
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Njoy Balder 1500 Manual de utilizare

Categorie
Surse de alimentare neîntreruptibile (UPS-uri)
Tip
Manual de utilizare

în alte limbi