20
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE160RXYDEG / AE260RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
16 kW P
Seasonal space heating
energy efficiency
s
138 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
Pdh 14,2 kW
-
COPd
(S)
2,06 -
Pdh 8,6 kW COPd
(S)
3,31 -
Pdh 5,5 kW COPd
(S)
5,23 -
Pdh 4,5 kW COPd
(S)
6,57 -
T Tj = bivalent temperature Pdh 14,2 kW T Tj = bivalent temperature COPd
(S)
2,06 -
U
Tj = operation limit
temperature
Pdh 14,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,82 -
V
For air-to-water heat pumps
Pdh - kW V
For air-to-water heat pumps
COPd
(S)
- -
W Bivalent temperature Tbiv -7 X
For air-to-water heat pumps:
Operation limit temperature
TOL -10
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL -
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 2,0 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 7080 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
44/66 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
117 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1432 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If
you are a professional looking
for
information on non-destructive disassembly, dismantling and battery
removability
, please send an email to:
[email protected]om